169,788 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    No full text
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Mitomycin C in highly myopic eyes - Author reply

    No full text
    Ophthalmology. 2005 Feb;112(2):208-18; discussion 219. Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes. Gambato C, Ghirlando A, Moretto E, Busato F, Midena E. SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy. Abstract PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes. DESIGN: Prospective, double-masked, randomized clinical trial. PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia. METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months). MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH. RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively). CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK. Comment in Ophthalmology. 2006 Feb;113(2):357; author reply 357-8

    A real electro-magnetic placebo (REMP) device for sham transcranial magnetic stimulation (TMS)

    No full text
    OBJECTIVE: There is growing interest in neuropsychiatry for repetitive transcranial magnetic stimulation (rTMS) as a neuromodulatory treatment. However, there are limitations in interpreting rTMS effects as a real consequence of physiological brain changes or as placebo-mediated unspecific effects, which may be particularly strong in psychiatric patients. This is due to the fact that existing sham rTMS procedures are less than optimal. A new placebo tool is introduced here, called real electro-magnetic placebo (REMP) device, which can simulate the scalp sensation induced by the real TMS, while leaving both the visual impact and acoustic sensation of real TMS unaltered. METHODS: Physical, neurophysiological and behavioural variables of monophasic and biphasic single-pulse TMS and biphasic 1Hz and 20Hz rTMS procedures (at different intensities) were tested in subjects who were expert or naïve of TMS. Results of the real TMS were compared with those induced by the REMP device and with two other currently used sham procedures, namely the commercially available Magstim sham coil and tilting the real coil by 90 degrees . RESULTS: The REMP device, besides producing scalp sensations similar to the real TMS, attenuated the TMS-induced electric field (as measured by a dipole probe) to a biologically inactive level. Behaviourally, neither expert nor naïve TMS subjects identified the "coil at 90 degrees " or the "Magstim sham coil" as a real TMS intervention, whilst naïve subjects were significantly more likely to identify the REMP-attenuated TMS as real. CONCLUSIONS: The "goodness of sham" of the REMP device is demonstrated by physical, neurophysiological, and behavioural results. SIGNIFICANCE: Such placebo TMS is superior to the available sham procedures when applied on subjects naïve to TMS, as in case of patients undergoing a clinical rTMS trial

    Dispelling the Myths Behind First-author Citation Counts

    No full text
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Suprathreshold 0.3 Hz repetitive TMS prolongs the cortical silent period: potential implications for therapeutic trials in epilepsy

    No full text
    OBJECTIVE: To investigate the after-effects of 0.3 Hz repetitive transcranial magnetic stimulation (rTMS) on excitatory and inhibitory mechanisms at the primary motor cortex level, as tested by single-pulse TMS variables. METHODS: In 9 healthy subjects, we studied a wide set of neurophysiological and behavioral variables from the first dorsal interosseous before (Baseline), immediately after (Post 1), and 90 min after (Post 2) the end of a 30 min long train of 0.3 Hz rTMS delivered at an intensity of 115% resting motor threshold (RMT). Variables under investigation were: maximal M wave, F wave, and peripheral silent period after ulnar nerve stimulation; RMT, amplitude and stimulus-response curve of the motor evoked potential (MEP), and cortical silent period (CSP) following TMS; finger-tapping speed. RESULTS: The CSP was consistently lengthened at both Post 1 and Post 2 compared with Baseline. The other variables did not change significantly. CONCLUSIONS: These findings suggest that suprathreshold 0.3 Hz rTMS produces a relatively long-lasting enhancement of the inhibitory mechanisms responsible for the CSP. These effects differ from those, previously reported, of 0.9-1 Hz rTMS, which reduces the excitability of the circuits underlying the MEP and does not affect the CSP. This provides rationale for sham-controlled trials aiming to assess the therapeutic potential of 0.3 Hz rTMS in epilepsy

    A Multi-Language Comparison of Influences on Author Verification using Character N-Grams

    No full text
    We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc

    A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C

    No full text
    Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (&gt; 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic

    Human ventral parietal cortex plays a functional role on visuospatial attention and primary consciousness. A repetitive transcranial magnetic stimulation study

    No full text
    In this paper, we used repetitive transcranial magnetic stimulation (rTMS) in 18 normal subjects to investigate whether the ventral posterior parietal cortex (PPC) plays a causal role on visuospatial attention and primary consciousness and whether these 2 functions are linearly correlated with each other. Two distinct experimental conditions involved a similar visual stimuli recognition paradigm. In "Consciousness" experiment, number of consciously perceived visual stimuli was lower by about 10% after rTMS (300 ms, 20 Hz, motor threshold intensity) on left or right PPC than after sham (pseudo) rTMS. In "Attentional" Posner's experiment, these stimuli were always consciously perceived. Compared with sham condition, parietal rTMS slowed of about 25 ms reaction time to go stimuli, thus disclosing effects on endogenous covert spatial attention. No linear correlation was observed between the rTMS-induced impairment on attention and conscious perception. Results suggest that PPC plays a slight but significant causal role in both visuospatial attention and primary consciousness. Furthermore, these high-level cognitive functions, as modulated by parietal rTMS, do not seem to share either linear or simple relationships

    A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration

    No full text
    Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic

    An Article About Albertus C. Van Raalte, Author Unknown, Except for Parts Taken from an Article by Anna C. Post

    No full text
    An article about Albertus C. Van Raalte, author unknown, except for parts taken from an article by Anna C. Post. The author knew first generation persons in the Holland settlement and therefore, the article has some value.https://digitalcommons.hope.edu/vrp_1890s/1012/thumbnail.jp
    corecore