217 research outputs found
COMPLEX-FORMATION OF GUANIDINATED BOVINE TRYPSIN-INHIBITOR (KUNITZ) WITH TRYPSIN, CHYMOTRYPSIN AND TRYPSINOGEN AS STUDIED BY THE SPIN-LABEL TECHNIQUE
Wenzel H, Tschesche H, VONGOLDAMMER E, NETZELMANN U. COMPLEX-FORMATION OF GUANIDINATED BOVINE TRYPSIN-INHIBITOR (KUNITZ) WITH TRYPSIN, CHYMOTRYPSIN AND TRYPSINOGEN AS STUDIED BY THE SPIN-LABEL TECHNIQUE. FEBS LETTERS. 1982;140(1):53-57
Eddy current pulsed thermography for basalt-carbon hybrid composites subjected to ballistic impacts: a numerical and experimental study
In this paper, eddy current pulsed thermography (ECPT) was used to detect the damages
caused by ballistic impacts in basalt-carbon hybrid fiber-reinforced polymer laminates. In
particular, different hybrid structures including intercalated stacking and sandwich-like
structures were used. Numerical simulations were performed to predict the damages due to
the impact loading. X-ray computed tomography (CT) was used for validation. Finally, a
comparative study based on the experiments and simulations was conducted
Rapid Testing muss Rapid Manufacturing ergänzen - Stoffliche Defekte und Gefüge rasch, zuverlässig und kostengünstig zerstörungsfrei prüfen - auch bei Stückzahl eins
Beitrag A5/4Die Prozessbedingungen bei Rapid-Technologien sind häufig schwieriger und haben eine geringere Wiederholgenauigkeit als herkömmliche Prozesse. Wo hohe Sicherheitsstandards und Ansprüche an die Zuverlässigkeit gelten, stellt dies ein Hindernis dar. Zerstörungsfreie Prüfverfahren erlauben hier Abhilfe, insbesondere wenn sie schnell arbeiten und zu angemessenen Kosten realisiert werden können. Für die Prüfung am fertigen Bauteil stehen bereits jetzt leistungsfähige Prüfverfahren bereit. Die Röntgen Computertomographie ist in den letzten Jahren deutlich leistungsfähiger, schneller und auch preisgünstiger geworden. Die Leistungsfähigkeit beim Nachweis von Poren, von Werkstoffgradienten und beim dimensionellen Messen ist erwiesen. Auch komplizierte (auch ständig wechselnde) äußere Objektformen und innere Strukturen stellen kein Hindernis dar. Eine andere schnelle Technik ist die aktive Thermographie, mit der Fehler nahe der Außenwand eines Objekts gefunden werden können. Eine Alternative zur visuellen Inspektion ist auch der luftgekoppelte Ultraschall. In dem Beitrag werden existierende Prüftechniken in Hinblick auf ihre Anwendung bei den Rapid-Technologien und bestehender Forschungsbedarf diskutiert. Es wird auch ein Ausblick auf mögliche zukünftige zerstörungsfreie Prüftechniken für die Anwendung während der Herstellung von Bauteilen gegeben.The process conditions in rapid-technologies are often more difficult and exhibit less repeatability than conventional processes. This is an obstacle when safety standards are high and when high reliablility is a must. Non-destructive testing techniques can help, in particular if they are working fast and can be realized at adequate cost. For testing on the final object, even now powerful testing techniques are available. X-ray computed tomography has become significantly more powerful, faster and also more competitive. Its performance for detection of pores, gradients in materials and for dimensional measuring has been proven. Complicated and changing object shapes can be tested without problems. Another fast technique is active thermography, which is able to detect defects close to the outer surface of an object. An alternative to visible inspection is air-coupled ultrasound. In the contribution existing testing techniques and remaining demand for research will be discussed with respect to their application in the rapid-technologies. An outlook for possible non-destructive testing solutions for the production process will be given
Non-linearity in photothermal radiometric imaging
Non-linear effects occurring in photothermal microscopes based on principle of photothermal radiometry are studied as a function of the laser power and of the modulation frequency. For stainless steel, a second harmonic component of up to 11 % of the fundamental amplitude is found. Phase shifts of up to 20 degrees are observed as a function of the modulation frequency. The nonlinearity is mainly due to Stefan-Boltzmann's law. The experimental results are in good agreement with a theoretical model based on the static and oscillating temperature distribution
Zerstörungsfreie Prüftechniken für Materialverbunde
In dem Vorhaben wurde zerstörungsfreie Prüftechniken für Materialverbunde untersucht und in Hinblick auf die Anwendbarkeit bei industriellen Fragestellungen bewertet. Eine zentrale Rolle spielt dabei die nichtlineare Ultraschalltechnik, bei der die Erzeugung höherer Harmonischer in einem Ultraschallsignal zur Bewertung der Festigkeit eines Verbunds herangezogen wird. Verbunde aus Metallen, Polymeren, Gläsern und Halbleitern wurden hierbei im Vergleich zur konventionellen linearen Ultraschalltechnik studiert. Ein besonderer Schwerbunkt lag bei Klebeverbindungen und deren Alterung und Schädigung. Die Arbeiten reichten von Grundlagenversuchen bis zum Aufbau von industriellen Geräteträgern. Weitere Prüftechniken waren die dynamische Thermographie in Form der Impulsthermographie und der Lock-In Thermographie sowie die Shearographie mit tragbaren und ortsfesten Prüfsystemen. Im Ergebnis ist die nichtlineare Ultraschalltechnik wohl in Einzelfällen, jedoch noch nicht in der gewünschten Breite für die Klebetechnik reif für die technische Anwendung. Bei der Thermographie und der Shearographie wurde der Schritt vom Prüflabor in die Produktionsüberwachung vollzogen
Algorithmik zur Auswertung von Thermographiebildern bei der Lock-In- und Impulsthermographie
S.393-396In einem Überblicksbeitrag werden Auswertetechniken bei der aktiven dynamischen Thermographie behandelt. Die Kontrasterzeugung bei der Impulsthermographie wird über numerische Modellierung erläutert. Nachweiszeiten und Nachweisgrenzen der Thermographie werden beschrieben. Am Beispiel der Schichtdickenmessung mit Impuls- und Wärmewellentechnik werden typische Auswertealgorithmen dargestellt und gegenübergestellt
Algorithmik zur Auswertung von Thermographie-Bildern bei der Lock-In und der Impulsthermographie
Vortrag 6Die Kontrastausbildung bei einem Fehler unter der Oberfläche bei der blitzangeregten Impulsthermographie wird zunächst anhand einer numerischen Modellrechnung diskutiert. Daraus werden charakteristische Punkte in der thermischen Abklingkurve begründet. Ähnliche Betrachtungen werden auch für die Lock-In Thermographie dargestellt. Typische Signalverarbeitungsschritte sind aufgeführt und werden anhand von Testmessungen veranschaulicht. Ein Ausblick auf neuere Ansätze wie die Polynomentwicklung oder die numerische Filterung wird gegeben.The formation of thermal contrast for flash-induced thermography is discussed based on a numerical model calculation. Characteristic points in the thermal decay curve are labelled. Similar considerations are explicated for lock-in thermography. Typical signal processing steps are shown and illustrated based on test measurements. An outlook is given for latest approaches like polynomial expansion or numerical filtering
High-frequency ultrasound and microthermography - two techniques for high-resolution, non-destructive coating tests
S.2172-2176The two techniques high-frequency ultrasound in the frequency range 10-100 MHz and microthermography (photothermal radiometry) at modulation frequencies of 2 Hz to 5 kHz are discussed in comparison with respect to testing of coatings. Tungsten carbide coatings on steel are studied with high-frequency ultrasound , copper layers on aluminium nitirde are studied with microthermography. In one case thermal properties, in the other case elastic properties are of importance. Advantages of microthermography are due to the non-contact operation, advantages of high-frequency ultrasound are due to the direct relation between time-of flight and defect depth87Nr.
- …