A Measuring Instrument for In-Line and Real-Time Measurement of Blood- pCO2in Extracorporeal-Circulation
Since the late 1950s, blood CO2 can be measured by using electrodes and, more recently, also by using point-of-care instruments such as blood gas and chemistry analyzers. Nevertheless, nowadays no measurement method has succeeded in providing an economic, reliable, and accurate estimate of the blood- CO2 to be routinely used for the monitoring of extracorporeal (blood) circulation (ECC) treatments. Indeed, blood is a very complex biological matrix composed of several different constituents, thus apart from a limited maximum-admitted measurement error (about some mmHg) and a quite wide measuring interval (about [20, 100] mmHg), the measuring systems have to provide significant selectivity taking hemocompatibility and safety for the patient as a primary concern. In this article, we propose and demonstrate a measuring instrument consisting of a low-cost and disposable fluorescent pco-sensor that can be inserted in series with the bloodline, and a nondisposable optical head that contactless reads the sensor. The proposed measuring system is intrinsically safe for the patient, has adequate metrological performance, avoids blood sampling and the related issues, and may allow to comply with cost requirements. Preliminary tests, conducted simulating a 6-h ECC treatment by using bovine blood, revealed deviations from the reference measuring instrument of less than ±4 mmHg, while the blood- CO2 was varied in the range [20, 100] mmHg
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Preliminary investigation of the robustness of a fluorescent measuring system for in-line and real-time monitoring of blood-pH in extracorporeal circulation
The possibility to monitor blood-pH has long been acknowledged to provide significant information for the diagnosis, management and treatment of a variety of diseases and it would be of considerable support for the administration of several treatments such as, for example, extracorporeal (blood) circulation (ECC). During ECC, the patient’s blood flows outside the body in disposable bloodlines and devices for treatments such as blood purification or circulation/ventilation/oxygenation support. Although blood-pH can be measured since the early twentieth century by using ion-selective electrodes (ISEs) and, more recently, also by using point-of-care testing (POCT) instruments, nowadays no measurement method has fully succeeded in providing a cost-effective, reliable and accurate estimate of the blood-pH to be routinely used for its real-time monitoring. In a recent paper, we have proposed and demonstrated a measuring instrument for the in-line and real-time monitoring of blood-pH during ECC. Such a measuring system consists of a low-cost fluorescent disposable sensor that can be integrated into the bloodline and, of a non-disposable reading system that interrogates the sensor without contacting the patient’s blood. In this paper, we investigated the robustness of such a measuring system to variations of blood parameters such as blood flow and hematocrit. The obtained results demonstrate that, although during the tests the pH, flow, and hematocrit values were significantly varied — pH from ≈ 6.8 pH, to ≈ 7.4 pH; hematocrit from 32%, to 40%; flow from 250 ml/min, to 400 ml/min, — the measuring system continued to guarantee a measurement error inferior to ±0.04 pH, thus complying with the metrological requirements for in-line and real-time monitoring of blood-pH during ECC
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …