1,720,977 research outputs found

    Sensitive ‘two-steps’ competitive assay for gonadotropin-releasing hormone detection via SPR biosensing and polynorepinephrine-based molecularly imprinted polymer

    No full text
    The work reports an innovative bioassay for the detection of gonadorelin in urine, a gonadotropin-releasing hormone agonist widely used in fertility medicine and to treat hormonal dysfunctions. Gonadorelin is also a synthetic hormone listed by the World Anti-Doping Agency (WADA) and of interest in anti-doping controls. The main novelty relies on the development of a biocompatible, stable, and low-cost biomimetic receptor alternative to classic antibodies. Starting from norepinephrine monomer, a highly selective and sensitive molecularly imprinted polymer (MIP) was developed and optimized for optical real-time and label-free SPR biosensing. The selectivity has been addressed by testing a series of peptides, from high to low similarity, both in terms of molecular weight and primary sequence. Due to the very low molecular weight of gonadorelin (1182 Da), a ‘two-steps’ competitive assay was developed. Particular attention has been paid to the design of the competitor and its binding affinity constant towards the MIP, being a key step for the success of the competitive strategy. The SPR assay was first optimized in standard conditions and finally applied to untreated urine samples, achieving the sensitivity required by WADA guidelines. The MIP, tested in parallel with a monoclonal antibody, gave comparable results in terms of affinity constants and selectivity towards possible interfering analytes. However, the biomimetic receptor appears clearly superior in terms of sensitivity and reproducibility. This, together with its preparation simplicity, the extremely low-cost of the monomer and its reusability for hundreds of measurements, make polynorepinephrine-based MIPs powerful rivals to immune-based approaches in the near future for similar applications

    Colorimetric analysis of the early oxidation of dopamine by hypochlorous acid as preliminary screening tool for chemical determinants of neuronal oxidative stress

    No full text
    The hypochlorous acid produced by the innate immune system during inflammation characteristic of several neurodegenerative disorders is responsible for the generation of chlorinated byproducts of dopamine in neurons where this neurotransmitter reaches the highest concentration. Therefore, this physiological acid could play a key role in neuronal oxidative stress associated to aberrant dopamine-quinones (DQ) production. Here we report a model study simulating simplified conditions of HOCl reaction with dopamine (DA) in neurons, showing for the first time that DA is immediately converted by HOCl to the yellow colored DQ molecule. The DQ originated from dopamine oxidation results directly proportional to the total amount of the oxidant with excellent reproducibility. Furthermore, following the several evidences of the interplay between cytosolic dopamine and calcium in neurodegenerative disorders, we have verified that the presence of calcium cation influences the dopamine oxidation pathway likely due to the metal chelation by semiquinone formed in the early stage of dopamine oxidation. This experimental approach, based on the isolation of the highly reactive DQ molecule, could be useful for prelaminar investigation of the (putative) determinants of dopamine-poisoning derivatives formation

    Polydopamine-based quantitation of albuminuria for the assessment of kidney damage

    No full text
    Proteinuria is considered indicative of kidney damage that can be related to various adverse outcomes. Nowadays, there is a huge demand for routine urine screening methods to assess health risks in clinical setting without expensive procedures and long pretreatment of the sample. To address this issue, a polydopamine-based colorimetric assay to determine urinary albumin concentration in real samples is proposed here. The core of this approach relies on the established competitive adsorption of polydopamine film and human serum albumin onto the polystyrene surface of ELISA plates. Herein, we investigated the influence of temperature and the Tris-HCl buffer concentration on the polydopamine film growth. The absorbance of polydopamine film, after 24 h at 25 °C, decreases with the increase of HSA concentration, allowing the selective detection of HSA down to 0.036 ± 0.001 g L−1 in untreated urine. This simple and low-cost bioanalytical assay exhibited very good reproducibility, %CVmean = 2 in human urine, and was superior in terms of analytical performances to some standard methods available on the market, especially in comparison to the Bradford assay, for early screening and assessment of kidney damage. Graphical abstract: [Figure not available: see fulltext.

    3,3′,5,5′-tetramethylbenzidine as multi-colorimetric indicator of chlorine in water in line with health guideline values

    No full text
    Sanitizing solutions against bacterial and viral pathogens are of utmost importance in general and, in particular, in these times of pandemic due to Sars-Cov2. They frequently consist of chlorine-based solutions, or in the direct input of a certain amount of chlorine in water supply systems and swimming pools. Colorimetry is one of the techniques used to measure the crucial persistence of chlorine in water, including household chlorine test kits commonly based on colorimetric indicators. Here, we show a simple and cheap colorimetric method based on 3,3′,5,5′-tetramethylbenzidine (TMB), commonly used as chromogenic reagent for enzyme-linked immunosorbent assays. TMB is converted by chlorine to a colored molecule through a pH-dependent multi-step oxidation process where the chromaticity of TMB is directly proportional to chlorine content. This molecule offers several advantages over other commonly used reagents in terms of safety, sensitivity, and, peculiarly, hue modulation, giving rise to the detection of chlorine in water with a multi-color change of the indicator solution (transparent/blue/green/yellow). Moreover, through the appropriate setting of reaction conditions, such coloration is finely tunable to cover the range of chlorine concentration recommended by international health agencies for treatment of drinking water and swimming pools and to test homemade solutions prepared by dilution of household bleach during health emergency events such as during the current pandemic. [Figure not available: see fulltext.

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado
    corecore