142 research outputs found

    Measurements and simulations of moisture in naturally ventilated barns in cold climates

    No full text
    ABSTRACT: New demands in farming industry in Norwegian sub-arctic regions have caused a need for larger animal buildings. To minimize the cost of the buildings, they are built without insulation. Uninsulated animal buildings in cold climates raise many new engineering challenges. Because of the lack of insulation, the walls of the buildings are exposed to a high risk of condensation. This is met with a high ventilation rate to remove the excess moisture. To monitor the risk of condensation, the indoor and outdoor climates are monitored in seven experimental barns for several years. Simulations of heat and moisture in the walls are performed with the acquired climate data and the risk of mould growth is determined. The experimental barns are placed in different climates with minimum three day temperatures ranging from -51˚C in the inland to -13˚C in the coastal zone. Also the humidity in the wooden walls is monitored for a shorter period to be able to validate the heat and moisture simulations.Presenters: name: Thomas Thiis affiliation: (Norwegian University of Life Sciences) email: [email protected]

    Snow engineering: recent advances

    No full text
    International audienceThese proceedings provide an international state-of-the-art knowledge in the field of snow engineering (snow drift, structural loading, transportation, buildings / simulation, avalanche / Snow physics)

    Snow engineering: recent advances

    No full text
    International audienceThese proceedings provide an international state-of-the-art knowledge in the field of snow engineering (snow drift, structural loading, transportation, buildings / simulation, avalanche / Snow physics)

    Snow engineering: recent advances

    No full text
    International audienceThese proceedings provide an international state-of-the-art knowledge in the field of snow engineering (snow drift, structural loading, transportation, buildings / simulation, avalanche / Snow physics)

    Environmental & architectural phenomenology. Vol. 1, issue 2

    No full text
    Vol. 1, No. 2, Spring 1990 (includes "citations received,” book review of Thomas Thiis-Evensen's Archetypes in Architecture, and essay by Elizabeth Behnke)

    Environmental & architectural phenomenology. Vol. 1, issue 3

    No full text
    Vol. 1, No. 3, Fall 1990 (includes "citations received,” book review of Thomas Thiis-Evensen's Archetypes in Architecture, and essay by Anne Vittoria)

    Environmental & architectural phenomenology. Vol. 11, issue 3

    No full text
    Vol. 11, No. 3, Fall 2000 (includes “items of interest,” "citations received,” book review of Thomas Thiis-Evensen's Archetypes of Urbanism, essay by Ingrid Leman Stefanovic, and poem by Christine Rhone)

    Optimalisering av inneklima og energiforbruket i halvklimatiserte museumsbygninger

    No full text
    I dagens samfunn er det stort fokus på bevaring av historiske gjenstander og bygninger da de er av stor betydning for kulturarven. Bevaring av gjenstander i historiske bygninger har lenge vært en utfordring, og flere historiske bygninger har ikke den standarden som kreves for optimal bevaring. Det er i mange tilfeller ikke mulig å installere et ventilasjonsanlegg for å kontrollere inneklimaet av estetiske grunner, at bygget er verneverdig eller fredet. Gjenstander blir derfor alt for ofte ødelagt eller angrepet av muggsopp ved oppbevaring i historiske bygninger. Denne masteroppgaven ser på hvordan man kan bedre forholdene for gjenstandene inne i et halvklimatisert museumsbygg ved bruk av minst mulig energi. Det undersøkes også om en forenklet beregningsmetode for muggvekstrisiko er tilstrekkelig sammenlignet med en numerisk simulering. For å finne svar på dette er det gjort målinger av ute- og inneklimaet i tømmerhuset Snekkenes på Borgarsyssel museum i Sarpsborg kommune i Østfold. Målingene er gjort ved hjelp av en værstasjon plassert utenfor bygget og fem temperatur- og RF målere innendørs. Museet har frem til i dag hatt problemer med muggvekst på gjenstandene i Snekkenes på vinterhalvåret med panelovnene på 6 °C. Ved hjelp av simuleringsprogrammet WUFI og bruk av målte klimadata er det dokumentert at oktober og november er månedene med størst risiko for muggvekst. For å finne hvilke forhold som ikke gir risiko for muggvekst ble inneklimaet endret i månedene oktober og november. Det kan konkluderes med at alle rom i 1. etasje bør ha en settpunkttemperatur på 18 °C i september, oktober og november. Grunnet stor infiltrasjon på loftet vil ikke en avfukter ha særlig positiv effekt her, og en temperaturøkning vil kreve for mye energi. Energiforbruket er beregnet i simuleringsprogrammet IDA ICE og totalt simulert energiforbruk til romoppvarming i Snekkenes er 10 956,0 kWh for månedene september, oktober og november. Resten av året er det ifølge simuleringene ikke risiko for muggvekst og romoppvarming er da ikke nødvendig

    CLT buildings exposed to moisture during the construction process : an evaluation of the standard for execution of timber structures

    No full text
    Denne masteroppgåva omhandlar fuktpåverknad på massivtrebygg under byggeprosessen. Formålet har vore å finna ut om NS 3516 (Utføring av lastberande trekonstruksjonar) stiller tilstrekkelege krav til fuktsikkerheit, slik at utføringa av massivtrekonstruksjonar blir av god kvalitet. Oppgåva er eit casestudie der det er gjort målingar av fuktnivå på forskjellige stader i ein massivtrekonstruksjon bygd utan vern mot vêr. • Målingane er nytta til å sei noko om kva for bygningsdelar som er spesielt utsett for fuktpåkjenning. • Dei målte fuktverdiane er vurdert opp mot den lokale nedbørsmengda og relative fuktigheita. • Dei målte verdiane er også nytta for estimering av vekstvilkåra til mugg i løpet av utføringsfasen. Resultata er samanlikna med krava stilt til fuktsikkerheit i den nye standarden NS 3516. Resultata blir også knytt opp mot NS 3512( Måling av fukt i trekonstruksjonar), då denne er nødvendig for utføring etter NS 3516. Det vart utført fuktmålingar med fastmonterte sensorar i overkant og underkant på to av etasjeskiljarane. Med ein handhalden trefuktmålar vart det også utført ei rekke målingar over 5 veker. Desse vart utført på to sjakter i den indre delen av bygget, på ytre dekkekantar og på ein yttervegg i første plan. NS 3516 visere seg å ha svakheiter når det gjeld å sikra at utføring skjer utan biologisk vekst. Det er stilt krav til at fuktnivået i ein bygningsdel skal vera under 20 vekt% ved lukking, men det er ikkje spesifisert kva fuktnivå og kva varigheit av påkjenning som er tillaten under utføringa. Dersom byggeperioden er lang kan det allereie før lukking ha oppstått biologisk vekst i konstruksjonen. Dei høgaste fuktnivå vart registrert i overkant av dekke og under utskjeringar i vertikale element. For dei andre områda er det meir vilkårleg kvar dei høge fuktverdiane oppstår. Standaren sitt krav om å måla der det er anteke fuktigast eller størst risiko for biologisk vekst er i så måte ei passande formulering. Mengda nedbør og variasjonane i relativ luftfuktigheit (RF) er av direkte betyding ved bygging utan eit system som vernar mot vêrpåkjenningar. Det burde difor gjerast ei kvantitativ evaluering av det lokale klimaet i forkant av utføring. Denne vurderinga bør vidare ligga til grunn når vêrbeskyttelsesklasse og tiltak skal bestemmast.This master thesis deals with the impact of moisture on cross laminated timber (CLT) during the construction process. The goal has been to study if moisture management, which is part of the NS 3516 (Execution of timber structures) standard, is sufficient. Moisture content readings were taken from a CLT construction that had no external protection from weather elements. • The moisture readings obtained have been used to identify components that were significantly affected by moisture content. • The local weather, particularly precipitation and relative humidity, were also considered to check its impact on moisture content in CLT. • Finally, the moisture readings have been used to indicate the probability and rate of mould growth throughout the construction process. The results obtained have been compared against the NS 3516 to verify if the standard contains the right requirements to ensure good quality during the construction process. The findings were also compared against the NS 3512 (Measurement of moisture in timber structures), as this is necessary to comply to NS 3516. Stationary sensors were installed on both sides of the wooden slab on two levels of the building. In addition, many measurements were taken for 5 weeks from a handheld moisture meter. These readings were recorded on two shafts in the inner parts of the building and on the floor towards the outer edge of the building. Further readings were obtained on a wall on the ground floor as well. NS 3516 seems to have certain flaws when it comes to ensuring quality during the construction process. The requirements state that the moisture level of a building should be below 20 weight% when closed, but it fails to specify what moisture level is allowed during construction, prior to closing. The results show that if the construction periods extend for a long period of time, then the biological growth may have already occurred before its closed. Although the standard specifies that any visible mould fungi found must be eradicated before closing, it does not state all the necessary measures to prevent it. The building parts that are most prone to high moisture levels are the horizontal elements, such as the slab and below the cut-outs in vertical elements. For the other controlled areas, the readings of high moisture levels seem to be more arbitrary. The amount of precipitation and the variations in relative humidity (RH), directly affect a building built without a weather protection system. Therefore, local weather readings should be considered to make a quantified evaluation before starting the project. This evaluation should then be the basis for choosing which weather protection class is viable and what measures that are necessary.submittedVersionM-B

    Drying and risk of mould growth after water damage in horizontal timber roof elements

    No full text
    Bruken av massivtre har i løpet av de siste årene økt betraktelig, spesielt i Europa. Ettersom massivtre er et relativt nytt materiale, er det for lite kunnskap om dets oppførsel i ulike situasjoner. (referanse) Formålet med oppgaven er å se hvordan takelementer av massivtre takler store vannskader, sammenlignet med et luftet bjelkelagstak. Det ble studert hvorvidt dampbrems er fordelaktig for massivtre ved en vannskade, og hvordan kompakte takelementer av massivtre med ulike isolasjonsmaterialer håndterer soppangrep. Denne masteroppgaven er skrevet i forbindelse med prosjektet TrebyggTørk, som er et samarbeidsprosjekt mellom Treteknisk, Mycoteam, Viken Skog, Veidekke, Splitkon, Norsk Massivtre, Woodcon, Massivtre, Nordisk Massivtre, Trebruk014, Trefokus og NMBU. Prosjektet er finansiert av Skogtiltaksfondet. Treteknisk og Mycoteam (prosjektledere for TrebyggTørk) har tidligere studert uttørkingen til veggelementer av massivtre etter høy oppfukting, og hvordan disse taklet soppangrep under gunstige vekstforhold. Som en videreføring av dette forsøket har det vært ønskelig å gjøre et tilnærmet likt forsøk for horisontale massivtreelementer. I samarbeid med produsenter, leverandører og ledende entreprenører innenfor massivtre i Norge ble det bestemt å studere en simulert, stor vannskade på kompakte takelementer i tre, med hovedfokus på massivtre. Det er i den forbindelse utført to forsøk. Det første er et uttørkingsforsøk med fire forskjellige takkonstruksjoner på 1 m2; et krysslimt massivtreelement uten dampbrems, et krysslimt element med dampbrems, et kantstilt massivtreelement og et luftet bjelkelagstak. Takkonstruksjonene ble oppfuktet og fuktforløpet ble fulgt via HygroTrac-sensorer og veieceller i et delvis beskyttet utvendig klima. Hvert element har fire sensorer som registrerer temperatur, relativ luftfuktighet og fuktinnhold. Uttørkingsforsøket ble også simulert i det numeriske simuleringsprogrammet WUFIÒ. Det andre forsøket er et innsmittingsforsøk med ulike kompakte takelementer i mindre størrelse. I sistnevnte forsøk ble kompakte takelementer av krysslimt og kantstilt massivtre med ulike typer isolasjon sammenlignet med bjelkelagselementer, hvor samtlige ble dynket i en soppsuspensjon. Utviklingen av soppvekst under gunstige forhold ble studert de åtte påfølgende ukene. Som et tredje eksperiment ble Det gjøres oppmerksom på at uttørkingsforsøket vil avsluttes høsten 2018, og dermed presenteres kun foreløpige resultater i denne oppgaven. Det er ikke forventet at elementene vil tørke i særlig stor grad før vår- og sommersesongen 2018 på grunn av dårlige uttørkingsforhold i høst- og vintersesongen. Basert på foreløpige resultater i uttørkingsforsøket viser resultatene at det krysslimte massivtreelementet med dampbrems mellom isolasjon og treoverflate har størst uttørking. Her har fuktinnholdet en avtagende kurve, og det ser ut til at dampbremsen beskytter elementet mot tilføring av ny fuktighet. Resultatene kan endres mot forsøkslutt, og dette er dermed ikke en endelig konklusjon. For innsmittingsforsøket konkluderes det med at massivtreelementene (krysslimt og kantstilt) håndterer et soppangrep bedre enn bjelkelagselementene, og at porøse isolasjonstyper gir dårligere uttørkingsforhold og bedre vekstvilkår for sopp. Simuleringene i WUFI viste seg å ikke være egnet til å beskrive fukt- og uttørkingsforløpet til takelementene.CLT and other laminated timber elements are newer building materials, and their use has rapidly increased over the last years. As of today, there is limited information about the hygrothermal behaviour of the material, and how it reacts to changed conditions such as water damages (Espinoza et al. 2015). Therefore, this Master thesis sought to study the drying process of laminated timber roof elements and to investigate the risk of biological degradation, as well as whether or not vapour barriers are beneficial in case of a large-scale water damage. This Master thesis is written in conjunction with a collaborative project between the Norwegian Institute of Wood Technology, Mycoteam, Splitkon, Norsk Massivtre, the Norwegian University of Life Sciences and others, and is financed by Skogtiltaksfondet. The Norwegian Institute of Wood Technology and Mycoteam have compared the drying and mould growth of cross-laminated timber and timber frame dwelling partition walls after a water damage in an earlier study. As a continuation of this project, it was desirable to perform a similar experiment with horizontal laminated timber roof elements. In cooperation with different actors in laminated timber in Norway, it was decided to study a simulated excessive water damage on compact laminated timber roof elements. As part of this thesis, two experiments have been conducted to simulate excessive water damage on compact laminated timber roof elements. The first experiment investigated the drying process of four different roof constructions with dimensions 1x1 metre; two cross-laminated timber elements with and without vapour retarder, one screw-laminated timber element (SLT) and one timber frame element. 20 litres of water were added to each element, and excess water was drained after 48 hours. The roof elements were left to dry in a partly sheltered environment with no direct wind or rain exposure, but where the temperature and relative humidity (RH) varied according to outdoor conditions. The weight was continuously logged, along with temperature, RH and moisture content. Lastly, the drying process was simulated in the numerical simulation program WUFIÒ. The second experiment consisted of a mould growth test of several different smaller sized compact roof elements, where in the elements were contaminated by being soaked in a mould spore suspension. They were placed in an indoor environment, and the growth was monitored for eight weeks. It should be noted that only preliminary results are presented in this thesis, as the drying experiment will not end until autumn 2018 due to poor drying conditions in the colder months and necessary drying is not expected to take place until spring/summer 2018. Based on the preliminary results, the CLT element with vapour retarder is the component with the lowest and most rapid decrease of moisture content. It appears that the vapour retarder protects the timber by preventing water from reaching it. As the results may change, there is no final conclusion to be drawn from this experiment. The conclusion for the mould growth test is that the laminated timber elements (CLT and SLT) are better suited to handle mould growth than a traditional timber frame, and that porous insulation materials provide poorer drying conditions and thus better growth conditions. The simulations in WUFI proved not suitable for describing the moisture content and drying process of the roof elements.submittedVersionM-B
    corecore