1,720,964 research outputs found

    OTU-18 Silence of the LAMS: reducing risk in EUS guided drainage of pancreatic fluid collections

    No full text
    Introduction and aims: endoscopic ultrasound guided transmural drainage (ETD) followed by endoscopic transluminal necrosectomy (ETN) is the evidence based preferred modality of treatment for symptomatic pancreatic fluid collections (PFC). EUS guided insertion of a lumen apposing metal stent (LAMS) facilitates improved drainage of fluid and improves efficacy of ETN. There is recognised risk associated with the procedure, primarily including bleeding, stent displacement and buried stent. Recent ESGE guidelines on the management of acute necrotising pancreatitis describe the use of imaging prior to drainage and at a 4 week interval, primarily to quantify the solid component in the collection. No definitive imaging protocols are established. In our institution, a protocol was developed to reduce the risk of adverse events associated with drainage. This included pre-intervention arterial phase CT and if identified, prophylactic embolisation of underlying pseudoaneurysm. In addition, all patients underwent CT at 4-5 weeks post stent insertion to determine efficacy of drainage and quantify residual component to determine benefit of long term plastic stents. We sought to assess the impact of the protocol on reducing LAMS associated adverse events.Methods: we evaluated our practice over a two year period between November 2018 and 2020. Prospectively collected data was reviewed retrospectively for the rates of technical success, clinical success and adverse event.Results: a total of 56 ETD procedures were performed on 52 patients. The majority of patients in the cohort were male (70.6%) with a mean age of 58 years. All patients underwent an arterial phase CT prior to ETD. Nine patients (17.3%) required embolisation of a previously unrecognised pseudoaneurysm prior to ETD. All procedures were technically successful (100%). Thirty five (67.3%) patients underwent a single ETN and 10 (19.2%) had multiple ETN procedures. Twenty two (62.8%) patients had a 20mm lumen diameter stent inserted and the remainder 15mm. Forty eight patients (92%) achieved complete resolution of collection with a single stent. Four patients (8%) required either an additional stent (multi-gated approach) or additional percutaneous drain. Stent dislodgement occurred in 4 (7.6%) patients during ETN. The median duration of LAMS placement was 44 days. No procedural or delayed LAMS related complications occurred.Conclusion: appropriate pre-procedural cross-sectional imaging facilitates identification and treatment of underlying pseudoaneurysm in this complex patient group. Post procedure interval imaging enables quantification of the residual collection to determine the benefit of long term plastic stents or additional drainage procedure. Our experience suggests adherence to a rigorous imaging protocol may reduce the risk of complication associated with LAMS deployment

    Endoscopic management of intentional foreign body ingestion: experience from a UK centre

    No full text
    Objective: We report on the increasing incidence and outcomes from intentional foreign body ingestion (iFoBI) presenting to our hospital over a 5-year period. The aim was to assess the impact on services and to identify ways to safely mitigate against this clinical challenge.Design/Method: We performed a retrospective observational study of all patients presenting to a university hospital between January 2015 and April 2020 with iFoBI with a focus on objects swallowed, timing of endoscopy and clinical outcomes.Results: 239 episodes of iFoBI in 51 individuals were recorded with a significant increase in incidence throughout the study period (Welch (5, 17.3)=15.1, p<0.001), imposing a high burden on staff and resources. Items lodged in the oesophagus were more likely to lead to mucosal injury (p=0.009) compared with elsewhere. Ingested item type and timing of endoscopy were not related to complications (p=0.78) or length of stay (p=0.8). In 12% of cases, no objects were seen at endoscopy.Conclusion: In all except those patients with oesophageal impaction of the object on radiograph, there is no need to perform endoscopic extraction out of hours. A subset of cases can avoid endoscopy with an X-ray immediately prior to the procedure as a significant proportion have passed already. We discuss more holistic approaches to deal with recurrent attendances

    Management of infected post-pancreatic resection fluid collections under endoscopic ultrasound guidance using lumen apposing metal stent: a case series and review of the literature

    No full text
    Backgrounds/Aims: Post-operative pancreatic fistulas (POPF) and fluid collections (POPFC) remain significant sources of morbidity and mortality after pancreatic resections. There remains a paucity of literature describing endoscopic ultrasound (EUS) guided drainage of POPFC using a Hot AXIOS™ lumen apposing metal stent (LAMS).Methods: We conducted a retrospective study, encompassing all consecutive patients with POPFC managed using Hot AXIOS™ LAMS at our institution between January 2017 and December 2019. Primary outcome measures were technical and clinical success. Secondary outcome measures were adverse events and recurrence rates.Results: Five patients underwent EUS guided drainage using Hot AXIOS™ LAMS during the study period. Mean age of patients was 67.8 ± 2.16 years. The majority (60.0%) of patients were males. Median duration of symptom onset after surgery was 9 days. All patients presented with abdominal pain. Median size of the collection measured on computed tomography was 91 mm. Median interval time between symptom onset and EUS drainage was 30 days. Two patients required percutaneous drainage prior to EUS guided drainage. Technical and clinical success were achieved for all patients. No adverse events were observed. Median duration of follow-up was 90 days. No recurrence of collection occurred during the follow-up period.CConclusions: EUS guided drainage of POPFC using Hot AXIOS™ LAMS is a safe and effective treatment modality with technical and clinical success rates of 100% in our experience

    Attitudes to radiation safety and cholangiogram interpretation in endoscopic retrograde cholangiopancreatography (ERCP): a UK survey

    No full text
    Background: Fluoroscopy during endoscopic retrograde cholangiopancreatography (ERCP) exposes staff and patients to potentially harmful ionizing radiation. We performed a UK survey to explore trainee and trainer attitudes to radiation protection and cholangiogram interpretation in ERCP.Methods: An electronic 10-point survey was prospectively distributed to endoscopy unit leads, training programme directors between October and November 2019. Only UK-based ERCP trainees and trainers with hands-on procedural exposure were eligible for the survey.Results: The survey was completed by 107 respondents (58 trainees and 49 trainers), with an estimated overall response rate of 46%. Overall, 49% of respondents were up to date with their radiation protection course, 38% were aware of European Basic safety standards directive (BSSD), 38% wore radiation protection goggles, and 40% were aware of the average radiation screening dose per ERCP procedure. Compared with trainers, trainees were less likely to routinely wear thyroid protection shields (76% vs 92%; p=0.028), have awareness of the BSSD (20% vs 49%; p=0.037) or know their average procedural radiation dosages (21% vs 63%; p<0.001). With regard to cholangiogram interpretation, only 26% had received formal training, with 97% of trainees expressing a desire for further training.Conclusion: This survey highlights a relative complacency in safety attitudes to radiation protection during ERCP. These data provide impetus to improve training and quality assurance in radiation protection, which should be regarded as a mandatory safety aspect prior to commencing hands-on ERCP training

    Initial United Kingdom experience of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography

    No full text
    BACKGROUNDS/AIMS: Gallstone disease is a recognized complication of bariatric surgery. Subsequent management of choledocholithiasis may be challenging due to altered anatomy which may include Roux-en-Y gastric bypass (RYGB). We conducted a retrospective service evaluation study to assess the safety and efficacy of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) in patients with RYGB anatomy. METHODS: All the patients who underwent EDGE for endoscopic retrograde cholangiopancreatography after RYGB at two tertiary care centers in the United Kingdom between January 2020 and October 2021 were included in the study. Clinical and demographic details were recorded for all patients. The primary outcome measures were technical and clinical success. Adverse events were recorded. Hot Axios lumen apposing metal stents measuring 20 mm in diameter and 10 mm in length were used in all the patients for creation of a gastro-gastric or gastro-jejunal fistula. RESULTS: A total of 14 patients underwent EDGE during the study period. The majority of the patients were female (85.7%) and the mean age of patients was 65.8 ± 9.8 years. Technical success was achieved in all but one patient at the first attempt (92.8%) and clinical success was achieved in 100% of the patients. Complications arose in 3 patients with 1 patient experiencing persistent fistula and weight gain. CONCLUSIONS: In patients with RYGB anatomy, EDGE facilitated biliary access has a high rate of clinical success with an acceptable safety profile. Adverse events are uncommon and can be managed endoscopically

    Increased ERCP volume improves cholangiogram interpretation: a new performance measure for ERCP training?

    Full text link
    BACKGROUND/AIMS: Cholangiogram interpretation is not used as a key performance indicator (KPI) of endoscopic retrograde cholangiopancreatography (ERCP) training, and national societies recommend different minimum numbers per annum to maintain competence. This study aimed to determine the relationship between correct ERCP cholangiogram interpretation and experience. METHODS: One hundred fifty ERCPists were surveyed to appropriately interpret ERCP cholangiographic findings. There were three groups of 50 participants each: “Trainees,” “Consultants group 1” (performed >75 ERCPs per year), and “Consultants group 2” (performed >100 ERCPs per year). RESULTS: Trainees was inferior to Consultants groups 1 and 2 in identifying all findings except choledocholithiasis outside the intrahepatic duct on the initial or completion/occlusion cholangiogram. Consultants group 1 was inferior to Consultants group 2 in identifying Strasberg type A bile leaks (odds ratio [OR], 0.86; 95% confidence interval [CI], 0.77–0.96), Strasberg type B (OR, 0.84; 95% CI, 0.74–0.95), and Bismuth type 2 hilar strictures (OR, 0.81; 95% CI, 0.69–0.95). CONCLUSIONS: This investigation supports the notion that cholangiogram interpretation improves with increased annual ERCP case volumes. Thus, a higher annual volume of procedures performed may improve the ability to correctly interpret particularly difficult findings. Cholangiogram interpretation, in addition to bile duct cannulation, could be considered as another KPI of ERCP training

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore