Review of research progress on the electrical properties and modification of mineral insulating oils used in power transformers
In November 2017, the first ±1100 kV high-voltage direct-current power transformer in the world, which was made by Siemens in Nurnberg, passed its type test. Meanwhile, in early 2017, a ±1000 kV ultra-high voltage (UHV) substation was officially put into operation in Tianjin, China. These examples illustrate that the era of UHV power transmission is coming. With the rapid increase in power transmission voltage, the performance requirements for the insulation of power transformers are getting higher and higher. The traditional mineral oils used inside power transformers as insulating and cooling agents are thus facing a serious challenge to meet these requirements. In this review, the basic properties of traditional mineral insulating oil are first introduced. Then, the variation of electrical properties such as breakdown strength, permittivity, and conductivity during transformer operation and aging is summarized. Next, the modification of mineral insulating oil is investigated with a focus on the influence of nanoparticles on the electrical properties of nano-modified insulating oil. Recent studies on the performance of mineral oil at molecular and atomic levels by molecular dynamics simulations are then described. Finally, future research hotspots and notable research topics are discussed
Fault location in the outer sheath of power cables
With the development of power systems in recent years, the total amount of power cables in operation has increased greatly, and there are growing reports of cable failure. Cable failures may be due to various intrinsic or extrinsic factors and can lead to massive economic loss. With regard to high-voltage cables, such as 110 kV power cables, there are very few accurate reports on the actual fault observed. This article first analyses the possible causes of power cable outer sheath failure. It then introduces the bridge and step voltage methods, which are traditionally used for cable fault locating, and describes a new method for accurate fault locating in 110 kV cables, which uses the bridge method to pre-locate the fault and then the step voltage method to accurately determine the precise fault locating. Field testing confirms the applicability of the new method for accurate fault locating in 110 kV power cables. The results shown in this article may provide a good reference for the development of future research in related field
Innovative through-silicon-via formation approach for wafer-level packaging applications
Effect of applied DC voltages and temperatures on space charge behaviour of multi-layer oil-paper insulation
In this paper, space charge in a multi-layer oil-paper insulation system was investigated using the pulsed electroacoustic (PEA) technique. A series of measurements had been carried following subjection of the insulation system to different applied voltages and different temperatures. Charge behaviours in the insulation system were analyzed and the influence of temperature on charge dynamics was discussed. The test results shows that homocharge injection takes place under all the test conditions, the applied DC voltage mainly affects the amount of space charge, while the temperature has greater influence on the distribution and mobility of space charge inside oil-paper samples
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Space charge behavior in multi-layer oil-paper insulation under different DC voltages and temperatures
Oil-paper as a reliable insulation system is widely used in power transformers and cables. The dielectric properties of oil-paper insulation play an important role in the reliable operation of power equipment. However, the formation and dynamics of space charge can affect the performance of insulation material. In this paper, space charge in oil-paper insulation system has been investigated using the pulsed electroacoustic (PEA) technique. A series of measurements were carried out when the insulation system was subjected to different applied voltages at different temperatures. Charge behavior in the insulation system has been analyzed and the influence of temperature on charge dynamics was discussed. The test results show that homocharge injection takes place under all the test conditions, the applied dc voltage mainly effect the amount of space charge, while the temperature has greater influence on the distribution and mobility of space charge inside oil-paper sample
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
- …