1,720,965 research outputs found

    Widefield and Ultra-Widefield Retinal Imaging: A Geometrical Analysis

    Full text link
    Diabetic retinopathy (DR) often causes a wide range of lesions in the peripheral retina, which can be undetected when using a traditional fundus camera. Widefield (WF) and Ultra-Widefield (UWF) technologies aim to significantly expand the photographable retinal field. We conducted a geometrical analysis to assess the field of view (FOV) of WF and UWF imaging, comparing it to the angular extension of the retina. For this task, we shot WF images using the Zeiss Clarus 500 fundus camera (Carl Zeiss Meditec, Jena, Germany). Approximating the ocular bulb to an ideal sphere, the angular extension of the theoretically photographable retinal surface was 242 degrees. Performing one shot, centered on the macula, it was possible to photograph a retinal surface of ~570 mm2, with a FOV of 133 degrees. Performing four shots with automatic montage, we obtained a retinal surface area of ~1100 mm2 and an FOV of 200 degrees. Finally, performing six shots with semi-automatic montage, we obtained a retinal surface area of ~1400 mm2 and an FOV of 236.27 degrees, which is close to the entire surface of the retina. WF and UWF imaging allow the detailed visualization of the peripheral retina, with significant impact on the diagnosis and management of DR

    Ocular-Surface Regeneration Therapies for Eye Disorders: The State of the Art

    Full text link
    The ocular surface is a complex structure that includes cornea, conjunctiva, limbus, and tear film, and is critical for maintaining visual function. When the ocular-surface integrity is altered by a disease, conventional therapies usually rely on topical drops or tissue replacement with more invasive procedures, such as corneal transplants. However, in the last years, regeneration therapies have emerged as a promising approach to repair the damaged ocular surface by stimulating cell proliferation and restoring the eye homeostasis and function. This article reviews the different strategies employed in ocular-surface regeneration, including cell-based therapies, growth-factor-based therapies, and tissue-engineering approaches. Dry eye and neurotrophic keratopathy diseases can be treated with nerve-growth factors to stimulate the limbal stem-cell proliferation and the corneal nerve regeneration, whereas conjunctival autograft or amniotic membrane are used in subjects with corneal limbus dysfunction, such as limbal stem-cell deficiency or pterygium. Further, new therapies are available for patients with corneal endothelium diseases to promote the expansion and migration of cells without the need of corneal keratoplasty. Finally, gene therapy is a promising new frontier of regeneration medicine that can modify the gene expression and, potentially, restore the corneal transparency by reducing fibrosis and neovascularization, as well as by stimulating stem-cell proliferation and tissue regeneration

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Surgical Strategies to Manage Stromal Interface Irregularity Following Deep Anterior Lamellar Keratoplasty

    No full text
    Purpose: The purpose of this study was to describe the various surgical approaches to manage stromal interface irregularity following deep anterior lamellar keratoplasty (DALK). Methods: This interventional case series included patients requiring repeat keratoplasty procedures for stromal interface opacity and/or irregularity following DALK. The following surgical techniques with the aim of restoring transparency and regularity of the central optical zone and improving visual acuity in eyes that underwent unsuccessful DALK were performed: 1) simple anterior lamellar graft exchange, 2) repeat DALK with pneumatic dissection, 3) repeat DALK with deepening of manual lamellar dissection, 4) small diameter stripping of the central stroma-endothelium-Descemet complex and its replacement with a new endothelial lamella, and 5) 2-piece microkeratome-assisted mushroom penetrating keratoplasty. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), slit-lamp examination, tonometry, and anterior corneal tomography were evaluated preoperatively, as well as 3, 6, and 12 months after surgery. Intraoperative and postoperative complications were recorded. Results: Preoperative BCVA was less than 20/200 and improved to 20/40 or better in all cases, reaching 20/20 in 1 patient. Corneal clarity was restored in all eyes, and no recurrence of underlying disease was observed. No intraoperative or postoperative complications were reported. Conclusions: This case series describes several successful surgical approaches to improve the transparency and regularity of stromal interface obtained after a DALK procedure; the choice of the technique should be customized for the single eyes to still maintain the advantages of lamellar or minimally invasive grafts

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    Serial Sessions of a Novel Low-Level Light Therapy Device for Home Treatment of Dry Eye Disease

    Full text link
    INTRODUCTION: This study aimed to evaluate the changes that a recently developed at-home device using low-level light therapy (LLLT) produced in signs and symptoms of patients with dry eye disease (DED) owing to meibomian gland dysfunction (MGD). METHODS: In this prospective study, patients with DED owing to MGD not successfully responding to first-line therapy (tear substitutes and eye lid hygiene) were treated with four serial sessions (every other day) of mask based on LLLT technology and dedicated for home use (my-mask(®), Espansione Marketing S.p.A., Bologna, Italy). Non-invasive ocular surface examination was carried out by means of Keratograph 5M (Oculus, Wetzlar, Germany) before and after four mask sessions for the evaluation of (i) tear meniscus height (TMH); (ii) first and average non-invasive Keratograph breakup time (NIKBUT); (iii) meibomian gland loss (MGL). Ocular Surface Disease Index (OSDI) questionnaire was used to assess ocular discomfort symptoms. RESULTS: Overall, 17 patients (3 male, 14 female; mean age 61.47 ± 11.93 years) were enrolled and all of them regularly completed the entire cycle of four sessions without reporting any adverse event. The mean values of NIKBUT first and NIKBUT average increased significantly after treatment (from 5.29 ± 2.60 at T0 to 9.04 ± 3.49 s at T1 [P = 0.001] and from 9.40 ± 3.81 to 11.28 ± 2.81 s [P = 0.017]); in parallel, the mean value of TMH increased significantly from 0.27 ± 0.06 to 0.32 ± 0.09 mm (P = 0.029). Conversely, there were not statistically significant differences for MGL (P = 0.346). In addition, the mean value of OSDI score decreased after treatment (from 32.00 ± 7.96 at T0 to 20.71 ± 8.03 at T1; P < 0.001). CONCLUSIONS: One week of serial sessions of a newly developed LLLT device for home use significantly improved tear film production and stability along with ocular discomfort symptoms in patients with DED owing to MGD. These findings open up a new scenario for patients with MGD who can enjoy the unique benefits of LLLT at home
    corecore