1,720,966 research outputs found
Effect of fiber post and resin core restorations on fracture resistance and pattern of endodontically treated mandibular molars.
Fracture resistance and failure patterns of endodontically treated mandibular molars restored using resin composite with or without translucent glass fiber posts
The elastic modulus of the restorative material is important in restoring endodontically treated teeth. This study aimed to compare the fracture resistance and failure patterns of 90 mandibular molars restored using resin composites with or without fiber posts, with respect to the number of residual cavity walls. Five restoration types were performed corresponding to different wall defects (groups 1-5). Groups were divided in two subgroups corresponding to the use or absence of fiber posts. Teeth were loaded and resistance of specimens was measured as the axial compressive load to cause fracture and macroscopic fracture patterns were observed. One way ANOVA revealed a significant difference in fracture resistance (p < 0.001). Tukey post hoc test also revealed significant differences between groups as samples restored with fiber posts exhibited mostly restorable fractures. It was concluded that the resistance of endodontically treated mandibular molars restored with composite resins is mainly affected by the number of residual walls. Using fiber-reinforced posts optimized fracture patterns
Effect of different all-ceramic crown system on fracture resistance and failure pattern of endodontically treated maxillary premolars restored with and without glass fiber posts
Endodontically treated teeth are traditionally restored with a crown to prevent fracture. The aim of this study was to compare the fracture resistance and failure modes of endodontically treated maxillary premolars treated with or without a fiber post and restored with different types of crowns. Eighty human maxillary premolars were selected. After root canal treatment, the teeth were embedded in resin blocks and divided into four groups. Samples received MOD cavity preparations and were divided into two subgroups: with and without fiber posts and restored using porcelain fused to metal, lithium disilicate, fiber-reinforced composite, or zirconia crowns. The specimens were vertically loaded in the central fossa using a universal loading machine until failure, and the maximum breaking loads were recorded. Samples were perfused with Indian ink to highlight the fracture lines and the mode of failure that was classified as restorable or nonrestorable. Even without post, all crown designs resisted vertically applied forces beyond those that may be encountered in the mouth. Two-way analysis of variance revealed the use of a fiber post (p = 0.007) and the type of crown (p < 0.001) significantly affected the restorability of fractured teeth. The relationship between placing or not placing the post and the type of failure (restorable/nonrestorable) was found to be significant (χ2 test, p = 0.002). Although post placement resulted in higher fracture resistance values, these were significant for Empress II crowns only. The results suggest that the posts could contribute to the reinforcement and strengthening of pulpless maxillary premolars. With respect to failure modes, placement of fiber posts improved the fracture from nonrestorable to restorable patterns. This study suggests that the placement of fiber posts is necessary to improve fracture resistance even under full-coverage crowns. © 2007 American Association of Endodontists
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Effetto di diverse corone integrali in ceramica sulla resistenza alla frattura e la modalità di fallimento di premolari superiori trattati endodonticamente ricostruiti con e senza fibre di vetro.
Adhesion between prefabricated fiber-reinforced posts and different composite resin cores: a microtensile bond strength evaluation
Purpose: The aim of this study was to evaluate the bond strengths between various resin composites used as core materials (Multicore Flow, Ivoclar-Vivadent; Tetric Flow, Ivoclar-Vivadent; Filtek Flow, 3M-ESPE; Tetric Ceram, Ivoclar-Vivadent; Filtek Z250, 3M-ESPE), and an FRC post (FRC Postec Plus, Ivoclar-Vivadent) by means of the microtensile nontrimming technique.
Materials and Methods: Five experimental groups were used. For the microtensile nontrimming technique, 45 to 50 beam-shaped specimens per group were obtained from cylinders of core material, which had been built up around the post by progressively adding small increments of composite resin. Each specimen was loaded in tension until failure at either one of the two post/core interfaces present in each stick. The differences in interfacial bond strength among the groups were tested for statistical significance with the one-way ANOVA test, followed by the Dunnett test for post-hoc comparisons.
Results: The measured bond strengths in MPa were 17.29 +/- 6.02 for FRC+MultiCore Flow, 16.37 +/- 6.92 for FRC+Tetric Flow, 13.14 +/- 5.35 for FRC + Filtek Flow, 12.38 +/- 4.34 for FRC + Tetric Ceram, and 10.75 +/- 5.43 for FRC + Filtek Z250. The statistical analysis revealed that MultiCore Flow achieved significantly higher bond strengths than Filtek Flow (p = 0.03), Tetric Ceram (p < 0.001), and Filtek Z250 (p < 0.001). The bond strength of Tetric Flow was significantly higher than that of Filtek Z250 (p = 0.003).
Conclusion: For core buildup on a fiber post, dual-cure composites appear to be preferable to light-curing composites
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
