10 research outputs found
Sensitivity and Limit of Detection of biosensors based on ring resonators
In this work, we present a study of the Sensitivity (S) and Limit of Detection (LOD) of microring based photonic biosensors as a function of the waveguide composition and dimensions. The target is Aflatoxin, which is a toxin of major concern for south Europe dairy industry. The sensing device is based on an array of multiple SiON microring resonators, fiber-coupled to both an 850 nm VCSEL and a silicon photodetectors, packaged with a microfluidic circuit. Volumetric sensing with glucose–water solutions of various concentrations yields a best sensitivity of 112 nm/RIU. To link these results to the Limit of Detection of the sensors, we also measured the noise of our experimental readout system and then calculated the LOD of our sensors. We found a best value of LOD of 1.6 × 10−6 RIU (referred to volumetric sensing). Finally, we detected Aflatoxin in solutions of various concentrations (down to 1.58 nM) by functionalized sensors. The functionalization is based on a wet silanization and specific DNA-aptamer binding on the chip. Reproducibility and re-usability of the sensor are investigated by several chemical treatments. Optimum procedure allows multiple sequential measurements with a good endurance. This work was supported by the FP7 EU project “Symphony” (Grant agreement no.: 610580). Keywords: Biosensor, Whispering Gallery Mode, Ring resonator, Aflatoxin, Limit of Detection, Sensitivit
Microring Resonators and Silicon Photonics
Silicon Photonics is the technological to face the future challenges in data communications and processing. This technology follows the same paradigm as the technological revolution of the integrated circuit industry, that is, the miniaturization and the standardization. One of the most important building blocks in Silicon Photonics is the microresonator, a circular optical cavity, which enables many different passive and active optical functions. Here, we will describe the new physics of the intermodal coupling, which occurs when multi radial mode resonators are coupled to waveguides, and of the optical chaos, which develops in coupled sequence of resonators. In addition, an application of resonators in the label-free biosensing will be discussed
Estimation of coronary artery hyperemic blood flow based on arterial lumen volume using angiographic images
The purpose of this study is to develop a method to estimate the hyperemic blood flow in a coronary artery using the sum of the distal lumen volumes in a swine animal model. The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions where it is difficult to determine whether a particular lesion is the cause of ischemia. Therefore, a functional measure of stenosis severity is needed using angiographic image data. Coronary arteriography was performed in 10 swine (Yorkshire, 25-35 kg) after power injection of contrast material into the left main coronary artery. A densitometry technique was used to quantify regional flow and lumen volume in vivo after inducing hyperemia. Additionally, 3 swine hearts were casted and imaged post-mortem using cone-beam CT to obtain the lumen volume and the arterial length of corresponding coronary arteries. Using densitometry, the results showed that the stem hyperemic flow (Q) and the associated crown lumen volume (V) were related by Q = 159.08 V(3/4) (r = 0.98, SEE = 10.59 ml/min). The stem hyperemic flow and the associated crown length (L) using cone-beam CT were related by Q = 2.89 L (r = 0.99, SEE = 8.72 ml/min). These results indicate that measured arterial branch lengths or lumen volumes can potentially be used to predict the expected hyperemic flow in an arterial tree. This, in conjunction with measured hyperemic flow in the presence of a stenosis, could be used to predict fractional flow reserve based entirely on angiographic data
Estimation of coronary artery hyperemic blood flow based on arterial lumen volume using angiographic images
Microring Resonators and Silicon Photonics
Silicon Photonics is the technological to face the future challenges in data communications and processing. This technology follows the same paradigm as the technological revolution of the integrated circuit industry, that is, the miniaturization and the standardization. One of the most important building blocks in Silicon Photonics is the microresonator, a circular optical cavity, which enables many different passive and active optical functions. Here, we will describe the new physics of the intermodal coupling, which occurs when multi radial mode resonators are coupled to waveguides, and of the optical chaos, which develops in coupled sequence of resonators. In addition, an application of resonators in the label-free biosensing will be discussed
Quantification of fractional flow reserve based on angiographic image data
Coronary angiography provides excellent visualization of coronary arteries, but has limitations in assessing the clinical significance of a coronary stenosis. Fractional flow reserve (FFR) has been shown to be reliable in discerning stenoses responsible for inducible ischemia. The purpose of this study is to validate a technique for FFR quantification using angiographic image data. The study was carried out on 10 anesthetized, closed-chest swine using angioplasty balloon catheters to produce partial occlusion. Angiography based FFR was calculated from an angiographically measured ratio of coronary blood flow to arterial lumen volume. Pressure-based FFR was measured from a ratio of distal coronary pressure to aortic pressure. Pressure-wire measurements of FFR (FFR( P )) correlated linearly with angiographic volume-derived measurements of FFR (FFR( V )) according to the equation: FFR( P ) = 0.41 FFR( V ) + 0.52 (P-value < 0.001). The correlation coefficient and standard error of estimate were 0.85 and 0.07, respectively. This is the first study to provide an angiographic method to quantify FFR in swine. Angiographic FFR can potentially provide an assessment of the physiological severity of a coronary stenosis during routine diagnostic cardiac catheterization without a need to cross a stenosis with a pressure-wire