1,720,980 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Dosimetry of ultra-short high dose-per-pulse very high energy electrons
Detailed characterisation of a standard plane-parallel ionisation chamber has been made when exposed to high dose-per-pulse Very High Energy Electrons (VHEEs). First-of-their kind absolute dosimetry measurements using a graphite calorimeter have been conducted in a novel VHEE beam and ionisation chamber correction factors such as ion recombination have been shown to be significant. Ion recombination has been shown to increase with increasing dose-per-pulse, with a collection efficiency as low as 4% for the highest dose-per-pulse investigated, 5.26 Gy/pulse. Current theoretical recombination models provide a reasonable description of the ion recombination behaviour. Moreover, the free-electron fraction component of ion recombination models was shown to vary with dose-per-pulse, contrary to what is typically expected, and an updated model proposed in this work has been shown to provide a better fit to data than currently available recombination models.
Following the experimental campaigns, Monte Carlo (MC) simulations were conducted to determine stopping-power-ratios, perturbation factors and beam quality correction factors for a reference 12 MeV beam and 200 MeV user VHEE beams using the Geant4 general purpose MC code. A Fano test was conducted and several charged particle transport parameter configurations were found to pass the Fano cavity test. Modifications to current Geant4 default physics parameters were also determined in order to provide a passing Fano test at 200 MeV.
Stopping-power-ratios were found to agree within uncertainties with that found previously using EGSnrc at 12 MeV, however, perturbation factors were found to vary more than previous studies. The stopping-power-ratio at 200 MeV was found to be approximately 6% lower than what is estimated in dosimetry protocols for a reference beam quality with similar measurement depth, with a total perturbation of approximately 5%.
The beam quality correction factor, for the conversion of dose from the reference beam to that of the user beam, was found to lead to an approximately 10% reduction in measured chamber dose in comparison to what was originally determined.
Correction factors for the graphite calorimeter have also been calculated for the 200 MeV VHEE beam with the vacuum gap correction factor shown to be within 1% of unity.
Implementation of these new corrections to early experimental data largely remedies un-physical ion chamber measurements which showed greater than 100% ion collection efficiencies for a number of collecting voltages. It is now clear that improved dosimetry for VHEEs is vital to determine reasonable and accurate characterisations of secondary standard ionisation chambers
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Feasibility studies on the application of relativistic electron beams from a laser plasma wakefield accelerator in radiotherapy
Very high energy electrons (VHEEs) (100-250 MeV) have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with X-ray photons, which could confer possible radiobiological benefits. The rapid development of ultra-compact laser-plasma wakefield accelerators (LWFAs) is now providing a potential low cost device for VHEE radiotherapy. These beams have characteristics unlike any other beams currently used for radiotherapy: femotosecond radiation pulses, small field size and energies that exceed electron energies currently used in clinical applications. A set of Monte Carlo (MC) calculations have been performed to study dosimetric properties of VHEEs propagating in water. To assess radiation protection and safety handling issues, the generation of neutrons, induced activity and equivalent doses have been evaluated. A dosimetry system, consisting of EBT2 Gafchromic® film and EPSON Expression 10000XL scanner, for VHEEs has been established. EBT2 Gafchromic film turns out to be a robust dosimeter with a minor energy-dependent response over a broad range of beam energies and modalities, and can be successfully used for dosimetry of very high energy electron beams. The dosimetric measurements have been carried out using three different accelerators: a 20 MeV clinical LINAC, a 165 MeV conventional LINAC and a 135 MeV laser-plasma wakefield accelerator. The measurements have been compared with Monte Carlo simulations using the FLUKA code. Additionally, the set of dose measurements employing IBA CC04 ionisation chamber has been presented. Dosimetric measurements have been complemented by preliminary cancer cell irradiation studies to determine the toxicity and dose response to LWFA VHEEs of two lung cancer cell lines (A549 and H460). The efficacy of VHEEs on in vitro tumour cells has been assessed by clonogenic assay and γ-H2AX assay employing immunofluorescence detection of signalling molecules has been deployed to indicate DNA double-strand breaks and repair.Very high energy electrons (VHEEs) (100-250 MeV) have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with X-ray photons, which could confer possible radiobiological benefits. The rapid development of ultra-compact laser-plasma wakefield accelerators (LWFAs) is now providing a potential low cost device for VHEE radiotherapy. These beams have characteristics unlike any other beams currently used for radiotherapy: femotosecond radiation pulses, small field size and energies that exceed electron energies currently used in clinical applications. A set of Monte Carlo (MC) calculations have been performed to study dosimetric properties of VHEEs propagating in water. To assess radiation protection and safety handling issues, the generation of neutrons, induced activity and equivalent doses have been evaluated. A dosimetry system, consisting of EBT2 Gafchromic® film and EPSON Expression 10000XL scanner, for VHEEs has been established. EBT2 Gafchromic film turns out to be a robust dosimeter with a minor energy-dependent response over a broad range of beam energies and modalities, and can be successfully used for dosimetry of very high energy electron beams. The dosimetric measurements have been carried out using three different accelerators: a 20 MeV clinical LINAC, a 165 MeV conventional LINAC and a 135 MeV laser-plasma wakefield accelerator. The measurements have been compared with Monte Carlo simulations using the FLUKA code. Additionally, the set of dose measurements employing IBA CC04 ionisation chamber has been presented. Dosimetric measurements have been complemented by preliminary cancer cell irradiation studies to determine the toxicity and dose response to LWFA VHEEs of two lung cancer cell lines (A549 and H460). The efficacy of VHEEs on in vitro tumour cells has been assessed by clonogenic assay and γ-H2AX assay employing immunofluorescence detection of signalling molecules has been deployed to indicate DNA double-strand breaks and repair
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
