1,721,067 research outputs found
Framework for quantitative evaluation of 3D vessel segmentation approaches using vascular phantoms in conjunction with 3D landmark localization and registration
Improved registration of DCE-MR images of the liver using a prior segmentation of the region of interest
In Dynamic Contrast-Enhanced MRI (DCE-MRI) of the liver, a series of images is acquired over a period of 20 minutes. Due to the patient's breathing, the liver is subject to a substantial displacement between acquisitions. Furthermore, due to its location in the abdomen, the liver also undergoes marked deformation. The large deformations combined with variation in image contrast make accurate liver registration challenging. We present a registration framework that incorporates a liver segmentation to improve the registration accuracy. The segmented liver serves as region-of-interest to our in-house developed registration method called ALOST (autocorrelation of local image structure). ALOST is a continuous optimization method that uses local phase features to overcome space-variant intensity distortions. The proposed framework can confine the solution field to the liver and allow for ALOST to obtain a more accurate solution. For the segmentation part, we use a level-set method to delineate the liver in a so-called contrast enhancement map. This map is obtained by computing the difference between the last and registered first volume from the DCE series. Subsequently, we slightly dilate the segmentation, and apply it as the mask to the other DCE-MRI volumes during registration. It is shown that the registration result becomes more accurate compared with the original ALOST approach.ImPhys/Quantitative Imagin
Automatic estimation of retinal nerve fiber bundle orientation in SD-OCT images using a structure-oriented smoothing filter
Optical coherence tomography (OCT) yields high-resolution, three-dimensional images of the retina. A better understanding of retinal nerve fiber bundle (RNFB) trajectories in combination with visual field data may be used for future diagnosis and monitoring of glaucoma. However, manual tracing of these bundles is a tedious task. In this work, we present an automatic technique to estimate the orientation of RNFBs from volumetric OCT scans. Our method consists of several steps, starting from automatic segmentation of the RNFL. Then, a stack of en face images around the posterior nerve fiber layer interface was extracted. The image showing the best visibility of RNFB trajectories was selected for further processing. After denoising the selected en face image, a semblance structure-oriented filter was applied to probe the strength of local linear structure in a discrete set of orientations creating an orientation space. Gaussian filtering along the orientation axis in this space is used to find the dominant orientation. Next, a confidence map was created to supplement the estimated orientation. This confidence map was used as pixel weight in normalized convolution to regularize the semblance filter response after which a new orientation estimate can be obtained. Finally, after several iterations an orientation field corresponding to the strongest local orientation was obtained. The RNFB orientations of six macular scans from three subjects were estimated. For all scans, visual inspection shows a good agreement between the estimated orientation fields and the RNFB trajectories in the en face images. Additionally, a good correlation between the orientation fields of two scans of the same subject was observed. Our method was also applied to a larger field of view around the macula. Manual tracing of the RNFB trajectories shows a good agreement with the automatically obtained streamlines obtained by fiber tracking.ImPhys/Quantitative Imagin
Multi-voxel algorithm for quantitative bi-exponential MRI T<sub>1</sub> estimation
Quantification of the spin-lattice relaxation time, T1, of tissues is important for characterization of tissues in clinical magnetic resonance imaging (MRI). In T1 mapping, T1 values are estimated from a set of T1-weighted MRI images. Due to the limited spatial resolution of the T1-weighted images, one voxel might consist of two tissues, causing partial volume effects (PVE). In conventional mono-exponential T1 estimation, these PVE result in systematic errors in the T1 map. To account for PVE, single-voxel bi-exponential estimators have been suggested. Unfortunately, in general, they suffer from low accuracy and precision. In this work, we propose a joint multi-voxel bi-exponential T1 estimator (JMBE) and compare its performance to a single-voxel bi-exponential T1 estimator (SBE). Results show that, in contrast to the SBE, and for clinically achievable single-voxel SNRs, the JMBE is accurate and efficient if four or more neighboring voxels are used in the joint estimation framework. This illustrates that, for clinically realistic SNRs, accurate results for quantitative biexponential T1 estimation are only achievable if information of neighboring voxels is incorporated.Team Michel Verhaege
Loosely coupled level sets for retinal layers and drusen segmentation in subjects with dry age-related macular degeneration
Optical coherence tomography (OCT) is used to produce high-resolution three-dimensional images of the retina, which permit the investigation of retinal irregularities. In dry age-related macular degeneration (AMD), a chronic eye disease that causes central vision loss, disruptions such as drusen and changes in retinal layer thicknesses occur which could be used as biomarkers for disease monitoring and diagnosis. Due to the topology disrupting pathology, existing segmentation methods often fail. Here, we present a solution for the segmentation of retinal layers in dry AMD subjects by extending our previously presented loosely coupled level sets framework which operates on attenuation coefficients. In eyes affected by AMD, Bruch’s membrane becomes visible only below the drusen and our segmentation framework is adapted to delineate such a partially discernible interface. Furthermore, the initialization stage, which tentatively segments five interfaces, is modified to accommodate the appearance of drusen. This stage is based on Dijkstra's algorithm and combines prior knowledge on the shape of the interface, gradient and attenuation coefficient in the newly proposed cost function. This prior knowledge is incorporated by varying the weights for horizontal, diagonal and vertical edges. Finally, quantitative evaluation of the accuracy shows a good agreement between manual and automated segmentation.ImPhys/Quantitative Imagin
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Computational analysis of PET by AIBL (CapAIBL): a cloud-based processing pipeline for the quantification of PET images
7T multi-shell hybrid diffusion imaging (HYDI) for mapping brain connectivity in mice
Diffusion weighted imaging (DWI) is widely used to study microstructural characteristics of the brain. High angular resolution diffusion imaging (HARDI) samples diffusivity at a large number of spherical angles, to better resolve neural fibers that mix or cross. Here, we implemented a framework for advanced mathematical analysis of mouse 5-shell HARDI (b=1000, 3000, 4000, 8000, 12000 s/mm^2), also known as hybrid diffusion imaging (HYDI). Using q-ball imaging (QBI) at ultra-high field strength (7 Tesla), we computed diffusion and fiber orientation distribution functions (dODF, fODF) to better detect crossing fibers. We also computed a quantitative anisotropy (QA) index, and deterministic tractography, from the peak orientation of the fODFs. We found that the signal to noise ratio (SNR) of the QA was significantly higher in single and multi-shell reconstructed data at the lower b-values (b=1000, 3000, 4000 s/mm^2) than at higher b-values (b=8000, 12000 s/mm2); the b=1000 s/mm^2 shell increased the SNR of the QA in all multi-shell reconstructions, but when used alone or in <5-shell reconstruction, it led to higher angular error for the major fibers, compared to 5-shell HYDI. Multi-shell data reconstructed major fibers with less error than single-shell data, and was most successful at reducing the angular error when the lowest shell was excluded (b=1000 s/mm2). Overall, high-resolution connectivity mapping with 7T HYDI offers great potential for understanding unresolved changes in mouse models of brain disease
Correction of dental artifacts within the anatomical surface in PET/MRI using active shape models and k-nearest-neighbors
n combined PET/MR, attenuation correction (AC) is performed indirectly based on the available MR image information. Metal implant-induced susceptibility artifacts and subsequent signal voids challenge MR-based AC. Several papers acknowledge the problem in PET attenuation correction when dental artifacts are ignored, but none of them attempts to solve the problem. We propose a clinically feasible correction method which combines Active Shape Models (ASM) and k- Nearest-Neighbors (kNN) into a simple approach which finds and corrects the dental artifacts within the surface boundaries of the patient anatomy. ASM is used to locate a number of landmarks in the T1-weighted MR-image of a new patient. We calculate a vector of offsets from each voxel within a signal void to each of the landmarks. We then use kNN to classify each voxel as belonging to an artifact or an actual signal void using this offset vector, and fill the artifact voxels with a value representing soft tissue. We tested the method using fourteen patients without artifacts, and eighteen patients with dental artifacts of varying sizes within the anatomical surface of the head/neck region. Though the method wrongly filled a small volume in the bottom part of a maxillary sinus in two patients without any artifacts, due to their abnormal location, it succeeded in filling all dental artifact regions in all patients. In conclusion, we propose a method, which combines ASM and kNN into a simple approach which, as the results show, succeeds to find and correct the dental artifacts within the anatomical surface
- …
