1,720,960 research outputs found

    Single use instruments for total knee arthroplasty

    Full text link
    Aim Total knee arthroplasty represents a procedure that is successfully performed to relieve functional limitation and pain in advanced stages of osteoarthritis. In the next 20 years the number of these procedures will be increased about four times. Patient specific instrumentation (PSI) has been introduced in the past years. The aim of this study was to evaluate whether SUI are more useful in clinical, organizational and economic terms. Methods A database search about single use instrumentation (SUI) was conducted on PubMed and Google Scholar for the period 2010-2020 using the following key “total knee replacement”, “total knee arthroplasty”, “single use instruments”, and “disposable instruments”. The results of the selected studies were classified according to clinical, economic and organizational criteria. Results The main advantage of SUI has been reported to reduce costs, timely turnover of operating rooms, maximizing the operating room utilization and patient throughput, improving the number of outpatient total joint replacements. No difference has been found other than with regard to conventional instruments in terms of clinical outcome such as hip-knee-ankle angle and other radio-graphic parameters, Oxford Knee Score, while a decreased infection rate has been demonstrated. Regarding the economic aspect, a reduction of direct and indirect reduction of costs has been shown for the cost of instruments reprocessing, tray sterilization, 90-day infection rate. Conclusion The SUI can be an alternative to conventional instruments, but there are still few studies in the literature regarding clinical outcomes

    Hamstring Graft Preparation for ACL Reconstruction

    No full text
    Anterior cruciate ligament (ACL) reconstruction represents one of the most common procedures in orthopedic surgery. It usually involves the harvest of both gracilis and semitendinosus tendons from the ipsilateral knee. Different methods of hamstring graft preparation have been proposed in recent years, to create an adequate graft diameter reducing morbidity linked to gracilis tendon harvesting procedure. More recently, the use of only 1 of the tendons (semitendinosus) in a tripled or quadrupled arrangement has been described, especially in an all-inside type of reconstruction. Having a thicker tendon with a quadrupled semitendinosus (ST), instead of double gracilis and ST enables to have a graft with enough diameter to resemble more closely the native ACL and decreases the risk of graft re-rupture. The present study aims to describe different options of hamstring graft preparing, listing and analyzing each configuration to help surgeons to choose the most suitable graft type for their patients. © 2022, Open Medical Publishing. All rights reserved

    Cement augmentation for trochanteric fracture in elderly: A systematic review

    No full text
    Background: Cement augmentation of internal fixation of hip fracture has reported to improve fracture stability in osteoporotic hip fractures, reducing the risk of cut-out of the sliding screw through the femoral head. The purpose of present study was to perform a systematic literature review on the effects of augmentation technique in patients with osteoporotic hip fractures. Material and methods: A comprehensive literature search was systematically performed to evaluate all papers published in English language included in the literature between January 2010 and July 2020, according to the PRISMA 2009 guidelines. In vivo and in vitro studies, case reports, review articles, cadaveric studies, biomechanical studies, histological studies, oncological studies, technical notes, studies dealing with radiological classifications and studies on revision surgery were excluded. Results: A total of 5 studies involving 301 patients were included. Patients had a mean age of 84.6 years and were followed up for a mean period of 11 months. The proximal femoral fractures were stabilized with implantation of the PFNA or Gamma nail and augmentation was performed with two different cements: polymethylmethacrylate (PMMA) in 4 studies and calcium phosphate (CP) in one study. Overall, 57.5% of patients reached the same or greater preoperative mobility, and postoperative Parker Mobility Score and Harris Hip Score were acceptable. No significantly complications were observed, and no additional surgery related to the implant was required. Conclusion: The results of this systematic review show that cement augmentation is a safe and effectiveness method of fixation to treat trochanteric fractures

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore