1,720,979 research outputs found
Towards Zero Retraining for Myoelectric Control Based on Common Model Component Analysis
In spite of several decades of intense research and development, the existing algorithms of myoelectric pattern recognition (MPR) are yet to satisfy the criteria that a practical upper extremity prostheses should fulfill. This study focuses on the criterion of the short, or even zero subject training. Due to the inherent nonstationarity in surface electromyography (sEMG) signals, current myoelectric control algorithms usually need to be retrained daily during a multiple days' usage. This study was conducted based on the hypothesis that there exist some invariant characteristics in the sEMG signals when a subject performs the same motion in different days. Therefore, given a set of classifiers (models) trained on several days, it is possible to find common characteristics among them. To this end, we proposed to use common model component analysis (CMCA) framework, in which an optimized projection was found to minimize the dissimilarity among multiple models of linear discriminant analysis (LDA) trained using data from different days. Five intact-limbed subjects and two transradial amputee subjects participated in an experiment including six sessions of sEMG data recording, which were performed in six different days, to simulate the application of MPR over multiple days. The results demonstrate that CMCA has a significant better generalization ability with unseen data (not included in the training data), leading to classification accuracy improvement and increase of completion rate in a motion test simulation, when comparing with the baseline reference method. The results indicate that CMCA holds a great potential in the effort of developing zero retraining of MPR
User adaptation in long-term, open-loop myoelectric training: implications for EMG pattern recognition in prosthesis control
Objective. Recent studies have reported that the classification performance of electromyographic (EMG) signals degrades over time without proper classification retraining. This problem is relevant for the applications of EMG pattern recognition in the control of active prostheses. Approach. In this study we investigated the changes in EMG classification performance over 11 consecutive days in eight able-bodied subjects and two amputees. Main results. It was observed that, when the classifier was trained on data from one day and tested on data from the following day, the classification error decreased exponentially but plateaued after four days for able-bodied subjects and six to nine days for amputees. The between-day performance became gradually closer to the corresponding within-day performance. Significance. These results indicate that the relative changes in EMG signal features over time become progressively smaller when the number of days during which the subjects perform the pre-defined motions are increased. The performance of the motor tasks is thus more consistent over time, resulting in more repeatable EMG patterns, even if the subjects do not have any external feedback on their performance. The learning curves for both able-bodied subjects and subjects with limb deficiencies could be modeled as an exponential function. These results provide important insights into the user adaptation characteristics during practical long-term myoelectric control applications, with implications for the design of an adaptive pattern recognition system
A BCI System Based on Somatosensory Attentional Orientation
We propose and test a novel brain-computer interface (BCI) based on imagined tactile sensation. During an imagined tactile sensation, referred to as somatosensory attentional orientation (SAO), the subject shifts and maintains somatosensory attention on a body part, e.g., left or right hand. The SAO can be detected from EEG recordings for establishing a communication channel. To test for the hypothesis that SAO on different body parts can be discriminated from EEG, 14 subjects were assigned to a group who received an actual sensory stimulation (STE-Group), and 18 subjects were assigned to the SAO only group (SAO-Group). In single trials, the STE-Group received tactile stimulation first (both wrists simultaneously stimulated), and then maintained the attention on the selected body part (without stimulation). The same group also performed the SAO task first and then received the tactile stimulation. Conversely, the SAO-Group performed SAO without any stimulation, neither before nor after the SAO. In both the STE-Group and SAO-Group, it was possible to identify the SAO-related oscillatory activation that corresponded to a contralateral event-related desynchronization (ERD) stronger than the ipsilateral ERD. Discriminative information, represented as R-2, was found mainly on the somatosensory area of the cortex. In the STE-Group, the average classification accuracy of SAO was 83.6%, and it was comparable with tactile BCI based on selective sensation (paired-t test, P > 0.05). In the SAO-Group the average online performancewas 75.7%. For this group, after frequency band selection the offline performance reached 82.5% on average, with >= 80% for 12 subjects and >= 95% for four subjects. Complementary to tactile sensation, the SAO does not require sensory stimulation, with the advantage of being completely independent from the stimulus
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
