1,720,985 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Usability of a Hybrid System Combining P300-Based Brain-Computer Interface and Commercial Assistive Technologies to Enhance Communication in People With Multiple Sclerosis

    Full text link
    Brain-computer interface (BCI) can provide people with motor disabilities with an alternative channel to access assistive technology (AT) software for communication and environmental interaction. Multiple sclerosis (MS) is a chronic disease of the central nervous system that mostly starts in young adulthood and often leads to a long-term disability, possibly exacerbated by the presence of fatigue. Patients with MS have been rarely considered as potential BCI end-users. In this pilot study, we evaluated the usability of a hybrid BCI (h-BCI) system that enables both a P300-based BCI and conventional input devices (i.e., muscular dependent) to access mainstream applications through the widely used AT software for communication “Grid 3.” The evaluation was performed according to the principles of the user-centered design (UCD) with the aim of providing patients with MS with an alternative control channel (i.e., BCI), potentially less sensitive to fatigue. A total of 13 patients with MS were enrolled. In session I, participants were presented with a widely validated P300-based BCI (P3-speller); in session II, they had to operate Grid 3 to access three mainstream applications with (1) an AT conventional input device and (2) the h-BCI. Eight patients completed the protocol. Five out of eight patients with MS were successfully able to access the Grid 3 via the BCI, with a mean online accuracy of 83.3% (± 14.6). Effectiveness (online accuracy), satisfaction, and workload were comparable between the conventional AT inputs and the BCI channel in controlling the Grid 3. As expected, the efficiency (time for correct selection) resulted to be significantly lower for the BCI with respect to the AT conventional channels (Z = 0.2, p < 0.05). Although cautious due to the limited sample size, these preliminary findings indicated that the BCI control channel did not have a detrimental effect with respect to conventional AT channels on the ability to operate an AT software (Grid 3). Therefore, we inferred that the usability of the two access modalities was comparable. The integration of BCI with commercial AT input devices to access a widely used AT software represents an important step toward the introduction of BCIs into the AT centers’ daily practice

    P300-based brain-computer interface for environmental control: An asynchronous approach

    No full text
    Brain-computer interface (BCI) systems allow people with severe motor disabilities to communicate and interact with the external world. The P300 potential is one of the most used control signals for EEG-based BCIs. Classic P300-based BCIs work in a synchronous mode; the synchronous control assumes that the user is constantly attending to the stimulation, and the number of stimulation sequences is fixed a priori. This issue is an obstacle for the use of these systems in everyday life; users will be engaged in a continuous control state, their distractions will cause misclassification and the speed of selection will not take into account users' current psychophysical condition. An efficient BCI system should be able to understand the user's intentions from the ongoing EEG instead. Also, it has to refrain from making a selection when the user is engaged in a different activity and it should increase or decrease its speed of selection depending on the current user's state. We addressed these issues by introducing an asynchronous BCI and tested its capabilities for effective environmental monitoring, involving 11 volunteers in three recording sessions. Results show that this BCI system can increase the bit rate during control periods while the system is proved to be very efficient in avoiding false negatives when the users are engaged in other tasks

    Self-calibration algorithm in an asynchronous P300-based brain-computer interface

    No full text
    Objective. Reliability is a desirable characteristic of brain-computer interface (BCI) systems when they are intended to be used under non-experimental operating conditions. In addition, their overall usability is influenced by the complex and frequent procedures that are required for configuration and calibration. Earlier studies examined the issue of asynchronous control in P300-based BCIs, introducing dynamic stopping and automatic control suspension features. This report proposes and evaluates an algorithm for the automatic recalibration of the classifier's parameters using unsupervised data. Approach. Ten healthy subjects participated in five P300-based BCI sessions throughout a single day. First, we examined whether continuous adaptation of control parameters improved the accuracy of the asynchronous system over time. Then, we assessed the performance of the self-calibration algorithm with respect to the no-recalibration and supervised calibration conditions with regard to system accuracy and communication efficiency. Main results. Offline tests demonstrated that continuous adaptation of the control parameters significantly increased the communication efficiency of asynchronous P300-based BCIs. The self-calibration algorithm correctly assigned labels to unsupervised data with 95% accuracy, effecting communication efficiency that was comparable with that of supervised repeated calibration. Significance. Although additional online tests that involve end-users under non-experimental conditions are needed, these preliminary results are encouraging, from which we conclude that the self-calibration algorithm is a promising solution to improve P300-based BCI usability and reliability

    Influence of P300 latency jitter on event related potential-based brain-computer interface performance

    No full text
    Objective. Several ERP-based brain-computer interfaces (BCIs) that can be controlled even without eye movements (covert attention) have been recently proposed. However, when compared to similar systems based on overt attention, they displayed significantly lower accuracy. In the current interpretation, this is ascribed to the absence of the contribution of short-latency visual evoked potentials (VEPs) in the tasks performed in the covert attention modality. This study aims to investigate if this decrement (i) is fully explained by the lack of VEP contribution to the classification accuracy; (ii) correlates with lower temporal stability of the single-trial P300 potentials elicited in the covert attention modality. Approach. We evaluated the latency jitter of P300 evoked potentials in three BCI interfaces exploiting either overt or covert attention modalities in 20 healthy subjects. The effect of attention modality on the P300 jitter, and the relative contribution of VEPs and P300 jitter to the classification accuracy have been analyzed. Main results. The P300 jitter is higher when the BCI is controlled in covert attention. Classification accuracy negatively correlates with jitter. Even disregarding short-latency VEPs, overt-attention BCI yields better accuracy than covert. When the latency jitter is compensated offline, the difference between accuracies is not significant. Significance. The lower temporal stability of the P300 evoked potential generated during the tasks performed in covert attention modality should be regarded as the main contributing explanation of lower accuracy of covert-attention ERP-based BCIs

    Toward domotic appliances control through a self-paced P300-based BCI

    Full text link
    During recent years there has been a growing interest in Brain Computer Interface (BCI) systems as an alternative means of interaction with the external world for people with severe motor disabilities. The use of the P300 event-related potentials as control feature allows users to choose between various options (letters or icons) requiring a very short calibration phase. The aim of this work is to improve performances and flexibility of P300 based BCIs. An efficient BCI system should be able to understand user's intentions from the ongoing EEG, abstaining from doing a selection when the user is engaged in a different activity, and changing its speed of selection depending on current user's attention level. Our self-paced system addresses all these issues representing an important step beyond the classical synchronous P300 BCI that forces the user in a continuous control task. Experimentation has been performed on 10 healthy volunteers acting on a BCI-controlled domestic environment in order to demonstrate the potential usability of BCI systems in everyday life. Results show that the self-paced BCI increases information transfer rate with respect to the synchronous one, being very robust, at the same time, in avoiding false negatives when the user is not engaged in a control task
    corecore