297 research outputs found
Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries
Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy
Sudden cardiac death in forensic medicine – Swiss recommendations for a multidisciplinary approach
Sudden cardiac death (SCD) is by definition unexpected and cardiac in nature. The investigation is almost invariably performed by a forensic pathologist. Under these circumstances the role of the forensic pathologist is twofold: (1.) to determine rapidly and efficiently the cause and manner of death and (2.) to initiate a multidisciplinary process in order to prevent further deaths in existing family members. If the death is determined to be due to "natural" causes the district attorney in charge often refuses further examinations. However, additional examinations, i.e. extensive histopathological investigations and/or molecular genetic analyses, are necessary in many cases to clarify the cause of death. The Swiss Society of Legal Medicine created a multidisciplinary working group together with clinical and molecular geneticists and cardiologists in the hope of harmonising the approach to investigate SCD. The aim of this paper is to close the gap between the Swiss recommendations for routine forensic post-mortem cardiac examination and clinical recommendations for genetic testing of inherited cardiac diseases; this is in order to optimise the diagnostic procedures and preventive measures for living family members. The key points of the recommendations are (1.) the forensic autopsy procedure for all SCD victims under 40 years of age, (2.) the collection and storage of adequate samples for genetic testing, (3.) communication with the families, and (4.) a multidisciplinary approach including cardiogenetic counselling
Pace Mapping for the Identification of Focal Atrial Tachycardia Origin: A Novel Technique to Map and Ablate Difficult-to-Induce and Nonsustained Focal Atrial Tachycardia
Background - Focal atrial tachycardia (FAT) is extremely difficult to map and ablate when it is difficult to induce and nonsustained. The objective of this study is to evaluate the efficacy of pace mapping in identifying the FAT origin. Methods and Results - The study included 7 patients with drug-refractory FAT who experienced daily multiple episodes before ablation and presented with difficult-to-induce and nonsustained FAT and a distinct P wave morphology. Pace mapping was systematically performed in the areas of interest using 3-dimensional mapping to match the P wave morphology and paced intracardiac activation sequence recorded from multiple catheters. The anatomic origins of FAT were the right pulmonary vein (PV) in 3 patients, mitral annulus, crista terminalis, tricuspid annulus, and right-sided PV via a posterior conduction of previous PV isolation. In all patients, pace mapping obtained best-matched P wave morphology in â¥11/12 leads of surface ECG at the successful ablation site, and paced intracardiac activation sequence was identical to that of induced FAT. Focal ablation was delivered in 4 patients, including non-PV FAT in 3 and FAT in 1, via posterior gap along the previous right-sided PV isolation, and circumferential right-sided PV isolation was performed in the other 3 patients. No FAT was induced at the end of the procedure. All patients were free of arrhythmias without antiarrhythmic drugs during the 8.4±5.6-month follow-up. Conclusions - The combination of paced P wave morphology and intracardiac activation sequence can be used for the identification of FAT origin in patients with difficult-to-induce and nonsustained FAT
First clinical experience using a novel high-resolution electroanatomical mapping system for left atrial ablation procedures
Background: The Rhythmia mapping system was recently launched and allows for rapid ultra-high-resolution electroanatomical mapping. We evaluated the feasibility, acute efficacy and safety of this novel system for ablation of atrial fibrillation (AF) and left atrial (LA) tachycardia (AT). Methods and results: A total of 35 consecutive patients (age 64.3 ± 8.6 years, LA diameter 44.4 ± 5.8 mm) underwent catheter ablation for AF and/or AT. All procedures were performed using Rhythmia in conjunction with the Orion mini-basket catheter. Pulmonary vein isolation (PVI) and linear lesions were performed applying radiofrequency (RF) energy. PVI was confirmed by presence of entrance and exit block using the mini-basket catheter. In addition, pacing maneuvers assessed bidirectional conduction block across linear lesions. Procedure duration was 110.3 ± 33 min, fast acquisition mapping (FAM) time was 19 ± 9 min. A mean number of 10165 ± 5904 mapping points were acquired during the initial map and 6379 ± 3191 for a remap. A total number of 31 ± 15 RF applications were delivered within 45 ± 22 min. Total fluoroscopy time was 21 ± 5, 5 ± 2 min were used for FAM. We observed a significant learning curve for mapping duration (p = 0.01). Complications included pericardial tamponade (n = 1), transient air embolism in the right coronary artery (n = 1), and mild groin hematoma (n = 2). Conclusions: The present study is the largest to describe experience of LA ablation procedures using Rhythmia. PVI was achieved in all patients. Applying this ultra high-resolution electroanatomical mapping system under routine conditions leads to a high level of confidence. More data will be mandatory before final conclusions can be drawn
Direct Comparison of Point-by-Point and Rapid Ultra-High-Resolution Electroanatomical Mapping in Patients Scheduled for Ablation of Atrial Fibrillation
Introduction: Three-dimensional electroanatomical mapping (EAM) is an established tool facilitating catheter ablation. In this context, the novel Rhythmia system sets a new bar in fast high-resolution mapping. The aim of this study was to directly compare point-by-point versus rapid ultra-high-resolution EAM in patients scheduled for ablation of atrial fibrillation (AF) with focus on procedural data, acute success, and midterm clinical outcome. Methods and Results: A total number of 74 consecutive patients (48/74 male) with symptomatic AF were scheduled to undergo pulmonary vein isolation (PVI) using either Carto or Rhythmia. The Carto-guided procedures were performed using point-by-point acquisition according to our routine approach, whereas for Rhythmia, fast anatomical mapping was utilized. Comparing Rhythmia- versus Carto-guided ablation approaches, we observed a significantly longer total mapping time (P = 0.001), longer total fluoroscopy time (P = 0.001), more delivered RF-applications (P = 0.019), and longer total RF-duration (P = 0.002). There was no difference regarding total ablation time (P = 0.707), total procedure duration (P = 0.99), and acute procedural success. During follow-up, 84.8% of patients remained free from any AF/AT-recurrence using Carto versus 88.2% when using Rhythmia (P = 0.53). From KaplanâMeier analysis, the event rate estimations were 15% versus 13.5%, respectively. Conclusion: The present study reports our first clinical experience using Rhythmia in direct comparison with the established Carto system for AF ablation. Our data clearly demonstrate that Rhythmia was proved to be effective and well applicable but more data will be mandatory before final conclusions can be drawn
CardioMEA: comprehensive data analysis platform for studying cardiac diseases and drug responses
Introduction In recent years, high-density microelectrode arrays (HD-MEAs) have emerged as a valuable tool in preclinical research for characterizing the electrophysiology of human induced pluripotent stem-cell-derived cardiomyocytes (iPSC-CMs). HD-MEAs enable the capturing of both extracellular and intracellular signals on a large scale, while minimizing potential damage to the cell. However, despite technological advancements of HD-MEAs, there is a lack of effective data-analysis platforms that are capable of processing and analyzing the data, particularly in the context of cardiac arrhythmias and drug testing. Methods To address this need, we introduce CardioMEA, a comprehensive data-analysis platform designed specifically for HD-MEA data that have been obtained from iPSCCMs. CardioMEA features scalable data processing pipelines and an interactive web-based dashboard for advanced visualization and analysis. In addition to its core functionalities, CardioMEA incorporates modules designed to discern crucial electrophysiological features between diseased and healthy iPSC-CMs. Notably, CardioMEA has the unique capability to analyze both extracellular and intracellular signals, thereby facilitating customized analyses for specific research tasks. Results and discussion We demonstrate the practical application of CardioMEA by analyzing electrophysiological signals from iPSC-CM cultures exposed to seven antiarrhythmic drugs. CardioMEA holds great potential as an intuitive, userfriendly platform for studying cardiac diseases and assessing drug effects
What’s New in Arrhythmogenic Cardiomyopathies
Arrhythmogenic Cardiomyopathy (ACM) is a hereditary cardiomyopathy often presenting with sudden cardiac death (SCD) in young athletic individuals [...
Electroanatomical voltage mapping and what to consider abnormal in non-ischaemic cardiomyopathy: when one size does not fit all
High interobserver variability in the assessment of epsilon waves: Implications for diagnosis of arrhythmogenic right ventricular cardiomyopathy/dysplasia
Revision of the Task Force diagnostic criteria (TFC) for arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) has increased their sensitivity for diagnosis of early and familial forms of the disease. Epsilon wave (EW) is a major diagnostic criterion in the context of ARVC/D, which, however, remains not quantifiable and therefore may leave room for substantial subjective interpretation
- …
