1,721,576 research outputs found
Context Matters? An Experimental Analysis of Willingness to Pay for (Environmental) Public Goods
Heparin-induced thrombocy-topenia and COVID-19
Heparin-induced thrombocytopenia (HIT) has not been included as a possible cause of thrombocytopenia in Coronavirus Disease 2019 (COVID-19) patients. We report a case of HIT in a patient with COVID-19 treated with heparin. A 78-year-old man was admitted to our hospital for acute respiratory failure and acute renal failure due to SARS-CoV-2 infection; in intensive care unit, one 5000IU heparin dose (day 0, platelet count 305000/μL). On day 2, haemoglobin started to decrease and heparin was stopped. On day 10, platelet count was 153000/μL and 5000IU calcium heparin subcutaneously twice daily was started. The platelet further decreased, reaching 49000/μL on day 17, and the patient was investigated for suspected HIT: an IgG specific chemiluminescence test for heparin-PF4 antibodies was positive and a femoral DVT was found at ultrasound. Argatroban was started, platelet count increased without any bleeding and thrombosis complication. Our experience shows that HIT may develop in heparin treated COVID-19 patients and should be included among the possible cause of thrombocytopenia in such patients. © the Author(s), 2021
Relevance of immobility as a risk factor for symptomatic proximal and isolated distal deep vein thrombosis in acutely ill medical inpatients
Immobility is a well-recognized risk factor for deep vein thrombosis (DVT) in surgical patients, whereas the level of DVT risk conferred by immobility is less defined in patients on medical wards. The aim of this study was to establish whether immobility and its duration are associated with the risk of DVT in acutely ill medical inpatients. We conducted a cohort study in acutely ill medical inpatients. Patients underwent whole leg ultrasound for suspected lower extremity DVT and were divided into two groups according to presence or absence of immobility, defined as total bed rest or sedentary without bathroom privileges. The endpoint was the detection of proximal DVT or isolated distal DVT (IDDVT). Among the 252 acutely ill medical inpatients with immobility (age 82.6 ± 10.3 years, female 63.9%), ultrasound showed 36 (14.3%) proximal DVTs and 39 (15.5%) IDDVTs, while there were 11 (4.4%) proximal DVTs and 26 (10.5%) IDDVTs among the 248 inpatients without immobility (age 73.6 ± 14.2 years, female 54.8%). The risk of proximal DVT was higher in immobile than in mobile patients (OR 3.59, 95% CI: 1.78–7.23, p = 0.0001), whereas the risk of IDDVT was similar between the two groups (OR 1.56, 95% CI: 0.92–2.66, p = 0.111). During the first 3 days of hospitalization, the frequency of all DVTs was similar in patients with and without immobility, but it was 0.26 ± 0.03 vs 0.18 ± 0.03, respectively, after 4 days. In conclusion, immobility for more than 3 days is a risk factor for proximal DVT in acutely ill medical inpatients. © The Author(s) 2021
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
A high precision power supply meter
This paper describes an efficient implementation of a power supply meter. The implementation is based on the Fourier Series decomposition algorithm, using CORDIC algorithm for complex mathematical computations. It is able to calculate RMS and peak values, phase shift, power factor, and complex, active, and reactive power for two periodic waveforms up to the 25th harmonic.
Several implementation alternatives are compared pointing out the advantages and the disadvantages of each one. Then the circuit structure at block level is described with emphasis on the advantages resulted from the use of CORDIC algorithm, followed by some considerations over precision issues
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Algorithm validation and hardware design interactive approach
In this paper we will describe a modality to speed up the design of the VLSI digital (mainly DSP) circuits and to reduce the design errors by increasing the interaction between the ad-hoc software program developed to validate the algorithm and the VHDL description and simulation. A real case of a digital power analyzer will be used for exemplificatio
- …
