86,594 research outputs found

    Diagnostic Performance and Confidence of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Cystic and Cysticlike Liver Lesions

    No full text
    OBJECTIVE. The aims of this study were to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) in the characterization of atypical cystic and cysticlike focal liver lesions in comparison with conventional US and to determine whether the use of CEUS can reduce the need for further diagnostic workup. SUBJECTS AND METHODS. In a 3-year period 48 patients with 50 atypical cystic and cysticlike lesions found at conventional US underwent CEUS. Diagnostic confirmation was obtained in cytohistopathologic examinations, with other imaging modalities, and in follow-up. Overall, there were 24 cystic lesions and 26 cysticlike solid lesions, specifically 32 benign and 18 malignant lesions. The conventional US and CEUS images and cine loops were reviewed by two blinded readers independently. Sensitivity, specificity, area under the ROC curve (Az), and interobserver agreement were calculated. RESULTS. Diagnostic performance improved after review of CEUS examinations by both readers (conventional US Az = 0.781 vs 0.972; CEUS Az = 0.734 vs 0.957). Interreader agreement increased, although slightly (conventional US weighted = 0.894; CEUS weighted = 0.953). In terms of differential diagnosis, the occurrence of correctly characterized lesions increased after CEUS for both readers (reader 1, 62% to 98%; reader 2, 56% to 96%). CONCLUSION. The development of low-acoustic-power CEUS has made it possible to identify several imaging features of cystic and cysticlike focal liver lesions that, in association with history and clinical findings, may help to correctly characterize them. Our data indicate the usefulness of CEUS in the evaluation of patients with these lesions

    Free-hand ultrasound strain elastography in evaluation of soft tissue tumors

    No full text
    Objective: The purpose of this study is to evaluate elastography in a wide spectrum of soft tissue superficial lesions by correlating the elastographic characteristics of these lesions with the elastographic score (ES) system established by Asteria. Methods: Forty patients with different superficial lesions of the soft tissues were studied, including lipomas, schwannomas, neuromas, epidermal inclusion cysts, "in transit" melanoma metastasis, arterio-venous malformation, and giant-cell tumor. An ultrasound examination was performed combined with color-Doppler and elastographic module. The B-mode criteria were echogenicity, margins, and structural homogeneity of the lesion. The color-Doppler criterion was irregular and mainly intra-nodular vascularization. ES 1-4 was attributed, in relation with the increasing tissue stiffness, according to the classification of Asteria adapted for soft tissues. Subsequently, we added to each single B-mode and color-Doppler criterion the ES 3 and 4, thus crossing two parameters of malignancy. All the presumptive diagnoses formulated were confirmed with the clinical data or with the histopathological result. Results: The hypoechoic appearance had the best diagnostic performance. Sensitivity was 87%, specificity 71%, positive predictive value (PPV) 80%, negative predictive value (NPV) 80%, and diagnostic accuracy 80%. There was a good correlation with the clinical and biopsy data, the irregularity of margins the worst performance, the inhomogeneity an intermediate. Color-Doppler had sensitivity 74%, specificity 82%, PPV 85%, NPV 70% and diagnostic accuracy 77.5%. Elastography had sensitivity 87%, specificity 94%, PPV 95%, NPV 84%, and diagnostic accuracy 90%. The combination hypoechoic appearance + ES3/ES4 showed sensitivity 83%, specificity 100%, PPV 100%, NPV 81%,and diagnostic accuracy of 90%. The combination of irregularity of margins + ES3/ES4 showed sensitivity 43%, specificity 100%, PPV 100%, NPV 59%, and diagnostic accuracy of 67.5%. The combination of inhomogeneity of the lesion + ES3/ES4 showed sensitivity 65%, specificity 94%, PPV 94%, NPV 68%, and diagnostic accuracy of 78%. The combination of the color-Doppler with the ES3/ES4 showed sensitivity 69.5%, specificity 100%, PPV 100%, NPV 71%, and diagnostic accuracy of 82.5%.In the combined evaluation, there was a significant increase in specificity, allowing healthy subjects to be categorized as correctly negative, with a reduction in false positives which also translates into an increase in PPV. Conclusions: Elastography alone is not sufficient for a correct diagnostic classification and must be considered as an additional parameter in the study of soft-tissue lesions. Although there was a good agreement between B-mode malignancy criteria and ES3/ES4, there is no significant improvement in sensitivity. Ultrasound assessment, especially of superficial lesions, cannot be separated from an integrated approach that foresees the additional and routine use of the elastographic examination

    The Tail and the String Sign: New Sonographic Features of Subcutaneous Melanoma Metastasis

    No full text
    No highly specific sonographic imaging findings to evaluate melanoma spread along the lymphatic vessels have ever been described. Between January 2009 and December 2012, a consecutive group of 531 melanoma patients at their initial stage or during follow-up for nodal or extra-nodal superficial metastasis were evaluated retrospectively to assess the presence of two sonographic findings demonstrating superficial lymphatic metastasis: a “tail” sign (a thin hypoechoic prolongation from one or both poles of a superficial metastasis) and a “string” sign (multiple in-transit lesions connected to each other in a rosary image). The total number of superficial metastatic lesions was 222. The tail sign was seen in 13 of the 222 lesions (5.9%). The string sign was detected in four patients (4.5%). These signs showed a low sensitivity with a very high specificity (100%). Tail and string signs may represent an additional finding of high specificity to be employed in the differential diagnosis of melanoma patients

    Added value of contrast-enhanced ultrasound (CEUS) with Sonovue® in the diagnosis of inferior epigastric artery pseudoaneurysm: report of a case and review of literature

    No full text
    The anatomical position of the inferior epigastric artery (IEA), within the rectus sheath, subjects patients to possible IEA injury during abdominal wall surgical and interventional procedures. Pseudoaneurysm arising from IEA is very uncommon with only 16 cases reported in the literature. We present a case of an IEA false aneurysm resulting from therapeutic paracentesis for ascites in a 71-year-old patient who came to our department for abdominal pain and signs of anemization. To our knowledge, no published reports are currently available describing an IAE pseudoaneurysm successfully diagnosed with contrast-enhanced ultrasound

    8-Chloro-cAMP enhances the growth inhibitory effect of cytotoxic drugs in human colon cancer cells

    No full text
    8-Cl-cAMP is a novel agent able to inhibit the growth of a wide variety of cancer cell types in vitro and in vivo by interfering with the protein kinase A type I (PKAI), a protein directly involved in mitogenic signalling and neoplastic transformation. In a recent phase I study conducted in cancer patients we have demonstrated that 8-Cl-cAMP, at doses devoid of toxicity, may achieve plasma concentrations in a range previously shown effective for cancer cell growth inhibition. In the present study we have investigated the effect of 8-Cl-cAMP in association with cytotoxic drugs acting by different mechanisms of action on the growth of LS174T and GEO human colon cancer cells. We here demonstrate that 8-Cl-cAMP administered after the cytotoxic drugs does not interfere with their growth inhibitory effect but rather is additive with most of them. Moreover, a synergistic effect was observed when 8-Cl-cAMP was administered after cisplatin or paclitaxel. The sequence of treatment seems to be important since pretreatment with 8-Cl-cAMP interferes with the effect of the cytoxic drugs. These results demonstrate that 8-Cl-cAMP is not only able to induce cell growth inhibition when used alone but also exhibit the capacity to enhance the efficacy of different cytotoxic drugs

    Morphological and dynamic evaluation of complex cystic focal liver lesions by contrast-enhanced ultrasound: current state of the art

    No full text
    Complex cystic and cystic-like focal liver lesions (FLLs) encompass a spectrum of disorders ranging from non-neoplastic conditions to benign and malignant tumors. In this prospective, the possibility of non-invasive differentiation of these lesions is extremely important, because the clinical implications and therapeutic strategies vary considerably. Because of its advantageous cost/benefit ratio, widespread availability and easy execution, ultrasound (US) is the first-line imaging modality in most countries for the initial liver survey and represents the imaging technique that usually detects a complex liver cyst. However, US showed poor efficacy in the differential diagnosis of complex cystic FLLs. Thus, for years, computed tomography (CT) and magnetic resonance (MR) imaging have been used for further assessment of these lesions. Recently, the development of low mechanical index real-time contrast-enhanced ultrasound (CEUS) technique performed with the second generation of US contrast agents has led to an accurate depiction of macrovasculature and microvasculature. The technique yields information about contrast enhancement of the liver and FLLs almost as CT and MRI do, but in real time and without the use of ionizing radiation. To date, there is only a small amount of evidence about the role of CEUS in the less common setting of complex liver cysts. The aim of this review is to offer an up-to-date overview on the state of the art of CEUS in the study of the most common complex cystic focal liver lesions. To our knowledge, there are no literature comprehensive reviews on this topic
    corecore