1,720,959 research outputs found

    Iterative micro-tomography of biopsy samples from truncated projections with quantitative gray values

    No full text
    AbstractThree-dimensional reconstruction from truncated two-dimensional projections cannot be solved analytically without prior knowledge of the sample or access to the non-truncated projections. To suppress reconstruction artifacts in region of interest (ROI) or local tomography, an iterative algorithm has been devised based on back-projection and re-projection, assuming an approximately cylindrical shape of the entire sample of general homogeneity, which is especially applicable for micro-tomography of biopsy samples from biological tissue. Tomographic reconstruction is iteratively refined by minimizing the mismatch between an empty ROI and the reconstruction from the difference between measured sinogram and forward projected ROI reconstruction. By numerical simulation and experimental demonstration, it is shown that the algorithm is not only able to reconstruct quantitative gray values, but also to reduce artifacts of peripheral glow, and may lead to increased image sharpness. The method is particularly suitable for examination of biopsy/autopsy-samples of soft tissue by micro/nano-computed tomography.Bundesministerium für Bildung und Forschunghttp://dx.doi.org/10.13039/50110000234

    Holographic imaging with a hard x-ray nanoprobe : Ptychographic versus conventional phase retrieval

    No full text
    We have performed near-field x-ray imaging with simultaneous object and probe reconstruction. By an advanced ptychographic algorithm based on longitudinal and lateral translations, full-field images of nanoscale objects are reconstructed with quantitative contrast values, along with the extended wavefronts used to illuminate the objects. The imaging scheme makes idealizing assumptions on the probe obsolete, and efficiently disentangles phase shifts related to the object from the imperfections in the illumination. We validate this approach by comparison to the conventional reconstruction scheme without simultaneous probe retrieval, based on the contrast transfer function algorithm. To this end, a set of semiconductor nanowires with controlled chemical composition (InP core, insulating SiO2 layer, and indium tin oxide cover) is imaged using the quasi-point source illumination realized by the hard x-ray nanofocus (26 nm x 39 nm spot size) of the ID16A Nano-Imaging beamline at the European Synchrotron Radiation Facility

    Validity of the empty-beam correction in near-field imaging

    No full text
    Extended wavefronts are used for coherent full field imaging of objects based on solving the inverse Fresnel diffraction problem. To this end, the conventional data correction step is given by division of the recorded object image by the intensity pattern of the empty beam. This division of intensities in the detection plane is a rather crude approximation for the separation of the complex valued object and probing fields. Here we present a quantitative error estimate, along with its mathematical proof, and confirm the prediction with numerical simulations. Finally the problem is illustrated with experimental results

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore