1,720,983 research outputs found
Quality of Life in Patients With Cancer Under Prolonged Anticoagulation for High-Risk Deep Vein Thrombosis: a Long-Term Follow-Up
Current guidelines recommend to prolong anticoagulant treatment in patients with cancer with venous thromboembolism (VTE); only few studies evaluated other parameters than cancer itself for selecting patients at higher risk of recurrent VTE. Long-term management of VTE is thus challenged by several controversies mainly for patients compliance. We here report results of a long-term follow-up in patients with deep vein thrombosis under anticoagulant treatment with low-molecular-weight heparin (LMWH) for residual vein thrombosis (RVT) detected at compression ultrasonography (CUS), 6 months after standard anticoagulant treatment. Patients with RVT were deemed at high risk of recurrences and included in the current observational study. They continued LMWH (reduced at 75% standard dose) for further additional 2 years after enrolment or until death. Patients were followed up every 3 months or earlier, if needed. Among ancillary study end points, there was the assessment of patients' quality of life during daily treatment with subcutaneous injections. Quality of life was determined by the EORTC-C30 questionnaire, administered by a skilled psychologist at enrolment and every 6 months follow-up visits. Overall, 128 patients were evaluated during follow-up. Mean global EORTC-C30 score at enrollment and at 6, 12 and 24 months follow-up were 52.1, 51.4, 50.8 and 50.1, respectively. There were no statistically significant differences between scores at enrolment and at the last available follow-up (P = .1). Long-term treatment with LMWH resulted, effective and safe, it was globally well tolerated and exempt of negative impact on quality of life of the enrolled patients. Reported results support long-term anticoagulant treatment with LMWH in cancer patients at risk of recurrent VTE
Lonoctocog alfa (rVIII-SingleChain) for the treatment of haemophilia A.
The administration of factor VIII (FVIII) concentrates on-demand or on long-term prophylaxis is the effective and safe standard of care of patients with hemophilia A (HA). Development of neutralizing antibodies against exogenous FVIII and the short half-life of the current available products remain major challenges. There is currently a great interest towards newer FVIII products with the goal of reducing the inhibitor risk and increasing the half-life. Area covered: In this review, the authors describe the efficacy and safety of rVIII-SingleChain (Lonoctocog alfa), the first and only single chain recombinant FVIII (rFVIII) molecule developed for the prevention and treatment of bleeding episodes in HA patients. The pre-clinical and clinical studies of rVIII-SingleChain as well as the results of the AFFINITY trial program in previously treated patients both adults and pediatric are presented and discussed. Expert opinion: The results from PTP studies document the efficacy and safety profile of the rVIII-SingleChain. However, even if rFVIII-SingleChain presents advantageous pharmacokinetic features compared to conventional rFVIII, it should not be considered as an EHL-FVIII while its immunogenicity is currently being studied in PUPs. The slightly better PK profile of rFVIII-SingleChain could however allow a small number of selected patients to be treated with a less intensive regimen
Emotions and Opinions of Adult Patients with Haemophilia During the COVID-19 (Coronavirus Disease 2019) Pandemic Caused by SARS-CoV-2: A Monocentric Survey
Acquired Hemophilia A Associated with Venous Thrombosis and Very High Inhibitor Titer: A Challenging Scenario
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
