1,721,009 research outputs found

    Left ventricular pseudoaneurysm following aortic valve prosthesis endocarditis

    No full text
    A 63-year-old man underwent aortic valve replacement and an early reoperation for recurrent endocarditis. Sixteen months later he presented with persistent fever and a 64-slice computed tomography (CT) scan revealed a subannular left ventricular pseudoaneurysm. He underwent successful left ventricular outflow tract reconstruction and aortic valve prosthesis, partial root and ascending aorta replacement. Copyright © Italian Federation of Cardiology

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Bicuspidy does not affect reoperation risk following aortic valve reimplantation

    No full text
    Aortic valve reimplantation has been shown to be a safe procedure. However, evidences of durability in bicuspid aortic valves (BAVs) are limited in the literature. Between 2002 and 2011, 132 patients (mean age 61 ± 12 years) underwent aortic valve reimplantation. In 24 patients (18%), aortic valve was bicuspid. Mean follow-up was 50 ± 26 months (range 1-102 months) and was 99% complete. In-hospital mortality was 0.8% (1 patient). Survival at 1 and 5 years was 99 and 94%, respectively. Overall freedom from aortic valve reoperation at 1 and 5 years was 96 and 90%, respectively, without significant difference between patients with bicuspid and tricuspid aortic valve. Freedom from aortic valve regurgitation >2+/4+, excluding patients reoperated, was at 1 and 5 years of 100 and 99%, respectively. Patients with valve cusp repair showed a higher rate of aortic valve reoperation; however, only postoperative aortic regurgitation >2+/4+ was significant risk factor for redo procedure at multivariate analysis. Aortic valve reimplantation in BAV without cusp repair provides excellent mid-term results. Further observations and longer follow-up are necessary to determine if BAV sparing, even in the presence of cusps alterations, could allow satisfying durability. © 2012 The Author

    Aortic valve replacement for paraprosthetic leak after transcatheter implantation

    No full text
    Conversion to surgical aortic valve replacement (AVR) has been described as a complication following transcatheter aortic valve implantation. This complication occurs in up to 8% of cases and, to the best of our knowledge, preoperative data and surgical outcomes of such patients have not been properly evaluated. Mild paraprosthetic regurgitation is commonly observed after transcatheter aortic valve implantation and usually leads to a benign clinical course. Unequal distribution of valve calcifications is described as a potential mechanism. We report a case of a perioperative paraprosthetic regurgitation that underwent successful urgent surgical AVR and review the incidence and results of paraprosthetic leaks following transcatheter implantation. © 2011 Wiley Periodicals, Inc

    Preserving the left subclavian artery patency in challenging proximal neck during thoracic endovascular aortic repair

    No full text
    Coverage of the left subclavian artery in thoracic endovascular aortic repair is still a controversial procedure. We report a case of 30-year-old patient with a chronic rupture of the aortic isthmus and short proximal lending zone (10 mm) treated by thoracic endovascular aortic repair using a balloon catheter inflated at the origin of the left subclavian artery (and protruding in the aortic arch) to both preserve the arterial branch patency and fully exploit the proximal neck

    Training in Coronary Artery Bypass Surgery: Tips and Tricks of the Trade

    No full text
    Coronary artery bypass is often the first procedure cardiac surgeons are confronted with during their residencies. This article discusses the surgical steps and the potential difficulties encountered during this procedure and how they can be solved. The “point of view” of an experienced surgeon is provided to the trainees and to the readers

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Postsurgical aortic false aneurysm: Pathogenesis, clinical presentation and surgical strategy

    No full text
    Postsurgical aortic false aneurysm occurs in less than 0.5% of all cardiac surgical cases and its management is a challenge in terms of preoperative evaluation and surgical approach. Although infections are well recognized as risk factors, technical aspects of a previous operation may have a role in pseudoaneurysm formation. The risk factors and clinical presentation of pseudoaneurysms and the surgical strategy are revisited in this article. © 2013 Italian Federation of Cardiology
    corecore