1,720,993 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
On‐chip purification of tetracycline from food matrices
Antibiotics are widespread both to treat human and animal diseases and to improve growth in food animals. However, their overuse in food-producing animals has led to critical issues for human health, such as the direct toxicity and the development of antibiotic-resistant bacterial strains. Therefore, the identification of traces of antibiotic in food before entering the market has became extremely important and brought out the need for novel bioanalytical methods and protocols. To meet this need, here, a microfluidic system was set up for the purification of tetracycline (TC) from raw milk, honey, and eggs. The system is based on the use of magnetic beads exposing copper ions, which are loaded in a microfluidic chamber and actuated by a ready-made device. Tetracycline is captured by copper ions present on the microbeads, purified from the unwanted raw material present in the initial sample and recovered by a suitable elution solution. Different elution solutions were tested and results were evaluated by X-ray photoelectron spectroscopy (XPS) and visible spectrometry. The microfluidic system was successfully employed for the purification of TC from raw milk, honey, and eggs after an initial dilution in buffer. The overall protocol was, therefore, demonstrated to efficiently purify tetracycline, laying the bases for a future implementation of in-field on-chip tests
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Cell transfer of information via miR-loaded exosomes: a biophysical approach
A new communication route among cells was reported in recent years, via extracellular vesicles and their cargo. Exosomes in particular are attracting increasing interest as privileged mediators of this cell communication route. The exosome-mediated transfer of nucleic acids, especially of microRNAs, is particularly promising for their use both as biomarkers of pathologies and as a therapeutic tool. Here, a simplified model of interaction among cells, microRNAs and vesicles is studied using a biophysical approach. A synthetic and fluorescent microRNA (i.e. miR-1246 conjugated with TAMRA) was selected to model cell communication, monitoring its internalization in cells. The fluorescent miR-1246, either naked or included in synthetic or natural vesicles, was incubated with human breast adenocarcinoma cells (MCF7) for different times. A comparison between this human microRNA and its DNA copy or an exogenous microRNA (from Caenorhabditis elegans) allowed assessment of the specificity of the information transfer through microRNAs, and especially associated with exosomes. The uptake of naked miR-1246 was indeed higher both in terms of number of targeted cells and intensity of fluorescence signal with respect to the other nucleic acids tested. The same occurred with miR-1246 loaded exosomes, evidencing a specific uptake only partially due to the lipidic components and present only when the human microRNA was loaded in exosomes, which were themselves derived from the same MCF7 cells
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Innovative silicon microgrippers for biomedical applications: Design, mechanical simulation and evaluation of protein fouling
The demand of miniaturized, accurate and robust micro-tools for minimally invasive surgery or in general for micro-manipulation, has grown tremendously in recent years. To meet this need, a new-concept comb-driven microgripper was designed and fabricated. Two microgripper prototypes differing for both the number of links and the number of conjugate surface flexure hinges are presented. Their design takes advantage of an innovative concept based on the pseudo-rigid body model, while the study of microgripper mechanical potentialities in different configurations is supported by finite elements' simulations. These microgrippers, realized by the deep reactive-ion etching technology, are intended as micro-tools for tissue or cell manipulation and for minimally invasive surgery; therefore, their biocompatibility in terms of protein fouling was assessed. Serum albumin dissolved in phosphate buffer was selected to mimic the physiological environment and its adsorption on microgrippers was measured. The presented microgrippers demonstrated having great potential as biomedical tools, showing a modest propensity to adsorb proteins, independently from the protein concentration and time of incubation
- …
