1,720,962 research outputs found

    The Prediction of Higher Heating Value, Lower Heating Value and Ash Content of Rice Husk Using FT-NIR Spectroscopy

    No full text
    Rice husk is the significant waste residue to be used as renewable energy. The growth of the use on rice husk for generating electricity lead to the verification of its properties. This research aimed to predict higher heating value (HHV), lower heating value (LHV), and ash content (A) of rice husk using Fourier Transform near infrared (FT-NIR) spectroscopy. Rice husk samples used in this experiment were collected from variable areas in Thailand in order to improve the model and get the robust model. The models were built using partial least squares (PLS) regression and validated by unknown sample collected from different area to calibration set. The prediction of HHV, LHV and A were represented the root mean square error of cross validation (RMSECV) of 199 J/g, 199 J/g, and 0.859%wb, respectively. The calibration model can predict the unknown sample successfully with the relative standard error of prediction (RSEP) of 1.104 %, 1.159 %, and, 5.975 %, which implied good performance of NIR model for future prediction. The results suggested that HHV, LHV, and A models should be able to assess the properties of rice husk samples and showed that NIR was reliable and suitable method for combustion system to screening material

    Precision test for spectral characteristic of NIR spectroscopy and bomb calorimeter for measuring higher heating value of Leucaena Leucocephala

    No full text
    The higher heating value (HHV) plays a significant role in determining of the energy potential of biomass. The method to receive this value using a bomb calorimeter takes a long time approximately of 15 minutes. The implementation of near infrared spectroscopy (NIR) technique by generating a prediction model can be replaced the former method in order to reduce time into 2 minutes. Therefore, the precision of both techniques have to be concerned in order to get the reliable values. The repeatability and reproducibility processes were carried out to evaluate the precision of both methods. It was found that the percentage difference of standard deviation (SD) from the mean of repeatability for the NIR was less than 5 % and for reproducibility was slightly over 5 % (but not over than 10%). The SD of repeatability and reproducibility of the bomb calorimeter were 54.6 J/g (0.3 % difference of average HHV value) and 81.3 J/g (0.5 % difference of average HHV value) respectively. The average HHV from the bomb calorimeter was 18,166.77±236.29 J/g. Both techniques showed very low percentage difference of the SD from the mean that revealed very high reliability and precision of measurements

    Gross calorific and ash content assessment of recycled sawdust from mushroom cultivation using near infrared spectroscopy

    No full text
    The aim of this study was to use the near infrared spectroscopy for predicting the gross calorific value (GCV) and ash content (AC) of recycled sawdust from mushroom cultivation. The wavenumber was in range of 12500-4000 cm-1 with the diffuse reflection mode was used. The NIR models was established using partial least square regression (PLSR) and was validated via using full cross validation. GCV model provided the coefficient of determination (R2), root mean square error of cross validation (RMSECV), ratio of prediction to deviation (RPD), and bias of 0.90, 445 J/g, 3.19 and 4 J/g, respectively. The AC model gave the R2, RMSECV, RPD and bias of 0.83, 1.7000 %wt, 2.44 and 0.0059 %wt, respectively. For prediction of unknow samples, GCV model provided the standard error of prediction (SEP) and bias of 670 J/g and -654 J/g, respectively. The AC model gave the SEP and bias of 1.84 %wt and 0.912 %wt, respectively. The result represented that the GCV and AC model probably used as the rapid method and non-destructive method

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore