1,720,958 research outputs found

    Intraoperative neuromonitoring versus visual nerve identification for prevention of recurrent laryngeal nerve injury in adults undergoing thyroid surgery

    Full text link
    Injuries to the recurrent inferior laryngeal nerve (RILN) remain one of the major post-operative complications after thyroid and parathyroid surgery. Damage to this nerve can result in a temporary or permanent palsy, which is associated with vocal cord paresis or paralysis. Visual identification of the RILN is a common procedure to prevent nerve injury during thyroid and parathyroid surgery. Recently, intraoperative neuromonitoring (IONM) has been introduced in order to facilitate the localisation of the nerves and to prevent their injury during surgery. IONM permits nerve identification using an electrode, where, in order to measure the nerve response, the electric field is converted to an acoustic signal. OBJECTIVES: To assess the effects of IONM versus visual nerve identification for the prevention of RILN injury in adults undergoing thyroid surgery. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, ICTRP Search Portal and ClinicalTrials.gov. The date of the last search of all databases was 21 August 2018. We did not apply any language restrictions. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing IONM nerve identification plus visual nerve identification versus visual nerve identification alone for prevention of RILN injury in adults undergoing thyroid surgery DATA COLLECTION AND ANALYSIS: Two review authors independently screened titles and abstracts for relevance. One review author carried out screening for inclusion, data extraction and 'Risk of bias' assessment and a second review author checked them. For dichotomous outcomes, we calculated risk ratios (RRs) with 95% confidence intervals (CIs). For continuous outcomes, we calculated mean differences (MDs) with 95% CIs. We assessed trials for certainty of the evidence using the GRADE instrument. MAIN RESULTS: Five RCTs with 1558 participants (781 participants were randomly assigned to IONM and 777 to visual nerve identification only) met the inclusion criteria; two trials were performed in Poland and one trial each was performed in China, Korea and Turkey. Inclusion and exclusion criteria differed among trials: previous thyroid or parathyroid surgery was an exclusion criterion in three trials. In contrast, this was a specific inclusion criterion in another trial. Three trials had central neck compartment dissection or lateral neck dissection and Graves' disease as exclusion criteria. The mean duration of follow-up ranged from 6 to 12 months. The mean age of participants ranged between 41.7 years and 51.9 years.There was no firm evidence of an advantage or disadvantage comparing IONM with visual nerve identification only for permanent RILN palsy (RR 0.77, 95% CI 0.33 to 1.77; P = 0.54; 4 trials; 2895 nerves at risk; very low-certainty evidence) or transient RILN palsy (RR 0.62, 95% CI 0.35 to 1.08; P = 0.09; 4 trials; 2895 nerves at risk; very low-certainty evidence). None of the trials reported health-related quality of life. Transient hypoparathyroidism as an adverse event was not substantially different between intervention and comparator groups (RR 1.25; 95% CI 0.45 to 3.47; P = 0.66; 2 trials; 286 participants; very low-certainty evidence). Operative time was comparable between IONM and visual nerve monitoring alone (MD 5.5 minutes, 95% CI -0.7 to 11.8; P = 0.08; 3 trials; 1251 participants; very low-certainty evidence). Three of five included trials provided data on all-cause mortality: no deaths were reported. None of the trials reported socioeconomic effects. The evidence reported in this review was mostly of very low certainty, particularly because of risk of bias, a high degree of imprecision due to wide confidence intervals and substantial between-study heterogeneity. AUTHORS' CONCLUSIONS: Results from this systematic review and meta-analysis indicate that there is currently no conclusive evidence for the superiority or inferiority of IONM over visual nerve identification only on any of the outcomes measured. Well-designed, executed, analysed and reported RCTs with a larger number of participants and longer follow-up, employing the latest IONM technology and applying new surgical techniques are needed

    A Review of the Literature on Videoscopic and Robotic Inguinal–Iliac–Obturator Lymphadenectomy in Patients with Cutaneous Melanoma

    No full text
    Inguinal–iliac–obturator lymph node dissection is essential in the treatment of patients with cutaneous melanoma exhibiting the clinical or radiological involvement of pelvic lymph nodes. The open procedure is associated with elevated mortality rates. Numerous minimally invasive approaches have been suggested to mitigate the impact of this surgery on the patient’s quality of life. The preliminary findings of robotic-assisted dissection have been documented in the literature. They demonstrate a decrease in potential issues linked to robotic-assisted treatments as compared to open or video laparoscopic methods. No implications have been reported for long-term oncological outcomes. The present study compares the outcomes in 64 patients with robotic procedures, 187 with videoscopic procedures, and 83 with open pelvic lymph node dissection (PLND). However, the quality of evidence is too low to draw any valid conclusions. The available literature shows that a robotic procedure is feasible and has similar complication rates and oncological outcomes to other methods. The reason for the shorter operative time is not clear, but is associated with lower hospital costs. It is probable that, from a surgeon’s point of view, robotic techniques offer several advantages over videoendoscopic techniques, such as three-dimensional imaging, ergonomic control, and tools that mimic human hand movements. Randomized controlled trials are necessary to validate the benefits of robotic inguinal–iliac–obturator lymph node dissection (RIIOL) compared to videoscopic and open procedures, but the recruitment rate is very low because of the restricted indications for lymph node dissection against the background of the continuously evolving system of therapy

    Sutureless FOCUS harmonic scalpel versus clamp-and-tie techniques for thyroidectomy: A meta-analysis of 43 randomized controlled trials

    No full text
    One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves’ injury. The “clamp and tie” technique was first introduced in the 19th century. Since then, a lot of other techniques have been adopted to facilitate the safe ligation and sectioning of thyroidal vessels; however, one of the most relevant advances is the introduction of energy-based devices (EBDs), which occurred three decades ago. Purpose: The aim of this systematic review and meta-analysis is to evaluate the safety and effectiveness of sutureless FOCUS harmonic scalpel (second generation EBDs) versus conventional clamps-and-tie technique) in total thyroidectomy. Results: This systematic review and meta-analysis represent the largest comparison in literature between the thyroidectomy procedure with the second-generation Advanced Harmonic Scalpel Ultrasonic Focus (UAS FOCUS) versus the conventional Clamp-and-Tie (CT) technique: as a matter of fact, it includes 43 randomized controlled trials (RCTs) and a total of 10.361 patients. The incidence of transient recurrent laryngeal nerve was statistically lower in patients undergoing UAS (3.99%) rather than CT (5.23%) (RR 0.79, 95% CI 0.63 to 0.99). The incidence of transient hypocalcemia was 11.3% in patients who underwent thyroidectomy with UAS FOCUS and 15.4% in those who underwent thyroidectomy with CT. Conclusion: Sutureless EBD is associated with a lower risk of damage to the laryngeal nerves and parathyroid glands. The rate of hypocalcemia and nerve paresis is indeed lower due to less thermic damage. Sutureless EBD can also diminish the rate of postoperative bleeding and cervical hematoma, a rare but potentially fatal complication

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    A review of the literature on videoscopic and robotic inguinal-iliac-obturator lymphadenectomy in patients with cutaneous melanoma

    No full text
    Abstract: Inguinal–iliac–obturator lymph node dissection is essential in the treatment of patients with cutaneous melanoma exhibiting the clinical or radiological involvement of pelvic lymph nodes. The open procedure is associated with elevated mortality rates. Numerous minimally inva-sive approaches have been suggested to mitigate the impact of this surgery on the patient’s quali-ty of life. The preliminary findings of robotic-assisted dissection have been documented in the lit-erature. They demonstrate a decrease in potential issues linked to robotic-assisted treatments as compared to open or video laparoscopic methods. No implications have been reported for long-term oncological outcomes. The present study compares the outcomes in 64 patients with robotic procedures, 187 with videoscopic procedures, and 83 with open pelvic lymph node dissec-tion (PLND). However, the quality of evidence is too low to draw any valid conclusions. The available literature shows that a robotic procedure is feasible and has similar complication rates and oncological outcomes to other methods. The reason for the shorter operative time is not clear, but is associated with lower hospital costs. It is probable that, from a surgeon’s point of view, robotic techniques offer several advantages over videoendoscopic techniques, such as three-dimensional imaging, ergonomic control, and tools that mimic human hand movements. Randomized controlled trials are necessary to validate the benefits of robotic inguinal–iliac–obturator lymph node dissection (RIIOL) compared to videoscopic and open procedures, but the recruitment rate is very low because of the restricted indications for lymph node dissection against the background of the continuously evolving system of therapy

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods
    corecore