1,721,020 research outputs found
Prosthodontic planning in patients with temporomandibular disorders and/or bruxism: A systematic review
Statement of problem The presence of temporomandibular disorders (TMDs) and/or bruxism signs and symptoms may present multifaceted concerns for the prosthodontist. Purpose The purpose of this systematic review was to evaluate the relationship between prosthetic rehabilitation and TMDs and bruxism. Material and methods Three research questions were identified based on different clinical scenarios. Should prosthodontics be used to treat TMD and/or bruxism? Can prosthodontics cause TMDs and/or bruxism? How can prosthodontics be performed (for prosthetic reasons) in patients with TMDs and/or bruxism? A systematic search in the PubMed database was performed to identify all randomized clinical trials (RCTs) comparing the effectiveness of prosthodontics with that of other treatments in the management of TMDs and/or bruxism (question 1); clinical trials reporting the onset of TMDs and/or bruxism after the execution of prosthetic treatments in healthy individuals (question 2); and RCTs comparing the effectiveness of different prosthodontics strategies in the management of the prosthetic needs in patients with TMDs and/or bruxism (question 3). Results No clinical trials of the reviewed topics were found, and a comprehensive review relying on the best available evidence was provided. Bruxism is not linearly related to TMDs, and both of these conditions are multifaceted. Based on the diminished causal role of dental occlusion, prosthetic rehabilitation cannot be recommended as a treatment for the 2 conditions. In theory, they may increase the demand for adaptation beyond the stomatognathic system's tolerability. No evidence-based guidelines were available for the best strategy for managing prosthetic needs in patients with TMDs and/or bruxism. Conclusions This systematic review of publications revealed an absence of RCTs on the various topics concerning the relationship between TMD and bruxism and prosthodontics. Based on the best available evidence, prosthetic changes in dental occlusion are not yet acceptable as strategies for solving TMD symptoms or helping an individual stop bruxism. Clinicians should take care when performing irreversible occlusal changes in healthy individuals and in patients with TMD and/or bruxism
Does increasing vertical dimension of occlusion in centric relation affect muscular activity? An electromyographic study
Objective: In many esthetic treatments, clinicians may consider the option to modify the maxillo mandibular position. A raise of the vertical dimension of occlusion (VDO) may help restore esthetics, increase the space for dental materials, and reduce the invasiveness of dental procedures. Traditionally, VDO increases are done by using the centric relation (CR) position. Despite a long history of use, the neuromuscular effects of different maxillo mandibular relations are not fully studied. The aim of this study was to investigate the effect of alterations of maxillo-mandibular relation from maximal intercuspal position (MIP) to a raised VDO CR position on jaw-elevator muscle activity. Materials and Methods: Fifteen healthy individuals were asked to carry out maximal voluntary clenching (MVC) in MIP and in CR on individual splints. Electromyographic (EMG) activity of the masseter and anterior temporalis muscles was assessed in μV as the root mean square of the amplitude. Specific indexes and ratios were also computed. Data analyzed in MIP and CR were compared by paired student's t-tests. Results: MVC levels were not negatively affected by a VDO increase in CR position. On the contrary masseter muscles showed a statistically significant increase (p < 0.005). No significant effect on the anterior temporalis was observed. Conclusion: These results suggest that no immediate negative effect on maximum voluntary clenching was induced by a VDO increase in CR position. A slight increase observed in EMG clenching levels could be explained by the increase in VDO when clenching on the splint. Clinical Implications: The results of this study support the use of CR position as a pragmatic reference position due to the absence of relevant or negative changes in neuromuscular function
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Vickers micro-hardness of new restorative CAD/CAM dental materials: Evaluation and comparison after exposure to acidic drink
CAD/CAM (computer-aided design/computer-aided manufacturing) for indirect restorative materials has been recently introduced in dentistry. The purpose of this study was to evaluate the change of the surface micro-hardness of different restorative CAD/CAM materials after exposure to a carbonated acidic drink (Coca-Cola, Coca-Cola Company, Milan, Italy). One hundred and eighty specimens of identical size (2 mm thickness) were obtained by sectioning each tested CAD/CAM block of four materials: a hybrid ceramic (CERASMARTTM, GC Corporation, Tokyo, Japan), a resin nano ceramic (LavaTM Ultimate, 3M, Monrovia, CA, USA), a nanohybrid composite (Grandio blocs, VOCO GmbH, Cuxhaven, Germany), and a zirconia-reinforced lithium silicate glass ceramic (VITA SUPRINITY® PC; VITA Zahnfabrik, Bad Sackingen, Germany). Forty-five specimens of each material were tested. Micro-hardness was measured at baseline, after 7 days and after 28 days. The data were analyzed. The micro-hardness of each material varied significantly after immersion in Coca-Cola. The nanohybrid composite had a high initial micro-hardness and the greatest percentage loss after acid exposure. The hybrid ceramic and the resin nano ceramic had similar percentage losses of micro-hardness values even if the second material had higher initial values. The zirconia-reinforced lithium silicate glass ceramic had the highest baseline values and the lowest percentage loss of micro-hardness. The different CAD/CAM materials presented different micro-hardness values before and after acid exposure
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
