1,720,983 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.

    No full text
    INTRODUCTION: The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in patients with difficult or small veins, such as children. This study was aimed to evaluate whether a transillumination device can advantageously replace the use of the tourniquet during the procedure for collection of blood specimens for RHT and thereby eliminating the discomfort and risk of spurious results caused by excessive or prolonged venous stasis. METHODS: Two hundred and fifty volunteers were divided into five groups (G1, G2, G3, G4 and G5) to compare the results of RHT between blood sample collected with transilluminator device (left arm) and with tourniquet application (right arm) for 30 s(G1), 60 s(G2), 90 s(G3), 120 s(G4) and 180 s(G5). RESULTS: No significant increases were observed in any of the haematological parameters tested in G1 when compared with blood collected by the transilluminator device. From G2 to G5, significant increases were observed for the platelet count, red blood cell count, haemoglobin, haematocrit, white blood cell count, neutrophils, monocytes and eosinophils. From G3-G5, further increases were observed for lymphocytes. Clinically significant variations were, however, observed for basophils in G2; red blood cell count, haemoglobin, haematocrit and basophils in G3 and eosinophils in G3 only. CONCLUSION: As such, considering that inappropriate use of the tourniquet is commonplace, we conclude that transillumination devices can represent a suitable tool to eliminate the venous stasis and to improve the quality of phlebotomy procedures

    Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test?

    No full text
    OBJECTIVE: Evaluate whether four different brands/types of heparin coated syringes can represent a source of variability in blood gas analysis (BGA).DESIGN AND METHODS: Blood was collected from one hundred volunteers into different syringes: Syringe I (lithium heparin and calcium balanced); Syringe II: in-house prepared (sodium heparin); Syringe III: (spray-dried calcium-balanced lithium heparin); Syringe IV (lyophilized electrolyte-balanced lithium heparin).RESULTS: Significant differences were as follows: a) Syringe I vs II: pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), base excess (BE), total hemoglobin (tHb), sodium (Na(+)), potassium (K(+)), calcium (Ca(2+)), glucose (Glu), lactate (Lac), O(2) Hb and p 50; b) Syringe I vs III: pH, pO(2), cHCO(3)(-), ctCO(2), BE, Na(+), Glu, Lac and p 50; c) Syringe I vs IV: pH, pO(2), sO(2), pCO(2)(t), BE, Na(+), K(+), Ca(2+), Glu, Lac and O(2) Hb; d) Syringe II vs III: pH, pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), ctO(2), tHb, Na(+), K(+), Ca(2+), Lac and p 50; e) Syringe II vs IV: pH, pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), BE, tHb, Na(+), K(+), Ca(2+), Lac, O(2) Hb and p 50; f) Syringe III vs IV: pH, pO(2), sO(2), cHCO(3)(-), ctCO(2), ctO(2), BE, Na(+), K(+), Ca(2+), O(2) Hb and p 50.CONCLUSION: The different manufacturers of syringes can represent new source of variability on BGA

    Impact of the phlebotomy training based on CLSI/NCCLS H03-A6-procedures for the collection of diagnostic blood specimens by venipuncture.

    Full text link
    Introduction: The activities involving phlebotomy, a critical task for obtaining diagnostic blood samples, are poorly studied as regards the major sources of errors and the procedures related to laboratory quality control. The aim of this study was to verify the compliance with CLSI documents of clinical laboratories from South America and to assess whether teaching phlebotomists to follow the exact procedure for blood collection by venipuncture from CLSI/NCCLS H03-A6 - Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture might improve the quality of the process. Materials and methods: A survey was sent by mail to 3674 laboratories from South America to verify the use of CLSI documents. Thirty skilled phlebotomists were trained with the CLSI H03-A6 document to perform venipuncture procedures for a period of 20 consecutive working days. The overall performances of the phlebotomists were further compared before and after the training program. Results: 2622 from 2781 laboratories that did answer our survey used CLSI documents to standardize their procedures and process. The phlebotomists' training for 20 days before our evaluation completely eliminated non-conformity procedures for: i) incorrect friction of the forearm, during the cleaning of the venipuncture site to ease vein location; ii) incorrect sequence of vacuum tubes collection; and iii) inadequate mixing of the blood in primary vacuum tubes containing anticoagulants or clot activators. Unfortunately the CLSI H03-A6 document does not caution against both unsuitable tourniquet application time (i.e., for more than one minute) and inappropriate request to clench the fist repeatedly. These inadequate procedures were observed for all phlebotomists. Conclusion: We showed that strict observance of the CLSI H03-A6 document can remarkably improve quality, although the various steps for collecting diagnostic blood specimens are not a gold standard, since they may still permit errors. Tourniquet application time and forearm clench should be verified by all quality laboratory managers in the services. Moreover, the procedure for collecting blood specimens should be revised to eliminate this source of laboratory variability and safeguard the quality

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing.

    No full text
    Sometimes in-vitro diagnostic devices (e.g. blood collection tubes) are not validated before use or when the producer's brand is changed. The aim of this study was to validate five brands of sodium citrate vacuum tubes. Blood specimens from 50 volunteers were collected in five different tube brands (I: Venosafe, II: VACUETTE, III: BD Vacutainer, IV: LABOR IMPORT and V: S-Monovette). Routine coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen (FIB)] were performed on ACL TOP instrument using HemosIL reagents. The significance of the differences between samples was assessed by paired Student's t-test, set at P < 0.005. Significant differences were observed for: PT when comparing I vs. II, I vs. III, I vs. V, II vs. III, II vs. IV, II vs. V, III vs. IV, III vs. V and IV vs. V; aPTT when comparing I vs. II, I vs. III, I vs. IV, II vs. IV, III vs. IV and IV vs. V. No differences were observed among brands for FIB determination. We suggest that every laboratory management should both standardize the procedures and frequently evaluate the quality of in-vitro diagnostic devices

    Preanalytical management: serum vacuum tubes validation for routine clinical chemistry.

    Full text link
    INTRODUCTION: The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing.MATERIALS AND METHODS: Blood specimens from 100 volunteers in five different serum vacuum tubes (Tube I: VACUETTE, Tube II: LABOR IMPORT, Tube III: S-Monovette, Tube IV: SST and Tube V: SST II) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas 6000 module. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P &lt; 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation.RESULTS AND CONCLUSIONS: Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices

    The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure.

    Full text link
    Introduction: The phlebotomists’ procedures are a still source of laboratory variability. The aim of this study was to verify the efficacy of minor modification in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document is able to reduce the tourniquet application time. Materials and methods: Thirty phlebotomists were invited to participate. Each phlebotomist was trained individually to perform the new venipuncture procedure that shortens the time of tourniquet release and removal. The phlebotomy training program was delivered over 8h. After training, all phlebotomists were monitored for 20 working days, to guarantee the adoption of the correct new procedures for collection of diagnostic blood specimens. After this time frame the phlebotomists were evaluated to verify whether the new procedure for blood collection derived from CLSI H03-A6 document was effective to improve the quality process by decrease in tourniquet application time. We compared the tourniquet application time and qualitative difference of phlebotomy procedures between laboratories before and after phlebotomy training. Results: The overall mean ± SD tourniquet application time before and after this intervention were 118 ± 1 s and 30 ± 1 s respectively. Minor modifications in procedure for blood collection were able to reduce significantly the tourniquet application time (-88 s, P < 0.001). Conclusions: The minor modifications in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document were able to reduce the tourniquet application time. Now the proposed new procedure for collection of diagnostic blood specimens by venipuncture could be considered usefulness and should be put into practice by all quality laboratory managers and/or phlebotomy coordinators to avoid preanalytical errors regard venous stasis and guarantee patient safety
    corecore