1,720,994 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Nuclear material detection with fast neutrons using the associated particle technique
Cette thèse étudie la détection de matière nucléaire avec la technique de la particule associée pour l’inspection de bagages abandonnés ou de conteneurs maritimes dans le domaine de la sécurité. Le principe consiste à mesurer, avec des scintillateurs plastique, les coïncidences entre particules de fissions induites par des neutrons de 14 MeV produits par un générateur basé sur la réaction 2H(3H,n)4He et équipé d’un détecteur alpha à localisation pour déterminer le temps d’émission et la direction du neutron opposé. La détection d’au moins trois particules de fission en coïncidence avec la particule qui permet de discriminer les matières nucléaires des matériaux bénins. Le système d’acquisition et les outils de simulation ont été qualifiés en passif avec des sources radioactives puis en actif avec le générateur et diverses cibles, validant les estimations de performances de systèmesd’inspection de bagages abandonnés ou de conteneurs maritimes réalisées par simulation numérique avec le code MCNP-PoliMi. Il est ainsi possible de détecter en quelques minutes, quelques kg d’uranium au centre d’un container rempli d’une matrice fer mêmesi l’échantillon est masqué par du plomb, à l’aide du signal des neutrons prompts de fission. La détection est plus difficile dans les matrices organiques en raison de la diffusion des neutrons interrogateurs et de fission sur les noyaux d’hydrogène. Par ailleurs, l’utilisation de scintillateurs plastiques à la place des compteurs gazeux à 3He a été évaluée pour caractériser le plutonium dans les colis de déchets radioactifs par mesure passive des coïncidences. La détection des neutrons de fission est beaucoup plus rapide,ce qui permet de minimiser le bruit accidentel dû aux réactions (,n). Les scintillateurs sont cependant plus sensibles aux rayonnements gamma et à la diaphonie entre détecteurs voisins, ce qui nécessite d’exploiter les coïncidences de multiplicité 3 avec un traitement des données spécifique pour limiter la diaphonie.This thesis investigates the detection of Special Nuclear Materials (SNM) by neutroninterrogation with the Associated Particle Technique (APT). 14 MeV neutrons areproduced from the 3H(2H,n)α fusion reaction in a sealed tube neutron generatorembedding a position-sensitive alpha detector. The alpha detector determines thedirection of the nearly opposite neutron and its time of flight. The detection of at leastthree prompt fission particles in coincidence with the tagged neutron signs the presenceof SNM. The acquisition system and simulation tools have been qualified in passive modewith radioactive sources and active mode with the generator and various targets,validating the simulation of inspection systems with MCNP-PoliMi. Calculations showthat the detection of a few kilograms of shielded SNM with the ATP is possible in ironcargo container, with the prompt fission neutrons signal. Detection is more difficult inorganic matrices due to tagged- and prompt fission neutrons scattering on hydrogennuclei. Furthermore, the use of plastic scintillators instead of 3He counters was studied tocharacterize the plutonium in the radioactive waste by passive coincidences measurement.Measurements at fast time scales of fast-neutrons instead of the long time scales ofthermal-neutrons reduce random coincidences that can occur with high (,n) reactionrate. The scintillators are however sensitive to gamma rays and cross-talk betweenadjacent detectors. Therefore, we used data-analysis algorithms to minimize cross-talkcontribution to measured three-fold coincidences
Identification of materials by an advanceded neutronic method.
Le système EURITRACK, basé sur la technique de la particule associée, vise à détecter des explosifs et des drogues dans les conteneurs maritimes avec des neutrons de 14 MeV produits par la réaction D(T,)n. La particule alpha et le neutron sont émis environ à 180° l'un de l'autre. Les réactions induites par le neutron produisent des rayonnements gamma qui sont détectés en coïncidence avec la particule alpha pour déterminer la direction et le temps de vol neutronique, et ainsi remonter à l'origine des rayonnements gamma dans le conteneur. La composition chimique est obtenue par déconvolution du spectre gamma en signatures élémentaires (C, O, N, Fe,…). Les rapports des nombres de coups du carbone, de l'oxygène et de l'azote sont convertis en proportions chimiques, afin de distinguer les matières organiques bénignes et illicites, via des facteurs calculés par simulation Monte Carlo et validés expérimentalement. Ils prennent en compte la modération neutronique et l'atténuation photonique dans les marchandises transportées. L'application à la caractérisation élémentaire des déchets radioactifs est aussi étudiée par simulation, avec des écrans et collimateurs pour limiter le bruit dû à l'émission radiologique des colis.The EURITRACK inspection system, based on the associated particle technique, aims at detecting explosives and narcotics in cargo containers with 14 MeV neutrons produced by the D(T,)n reaction. Alpha particle and neutron are emitted almost back to back. Reactions induced by fast neutrons produce gamma rays which are detected in coincidence with the alpha particle to determine the neutron direction. Neutron time-of-flight allows to determine gamma-ray origin inside the container. Information concerning material composition is obtained by unfolding the gamma spectrum into elemental signatures using a database of elemental spectra (C, O, N, Fe…). Carbon, oxygen, and nitrogen count ratios are converted into chemical proportions to distinguish illicit and benign organic materials. Conversion factors based on Monte Carlo simulations have been calculated and validated experimentally, taking into account neutron slowing down and photon attenuation in cargo materials. Application to the elemental characterisation of radioactive wastes is also studied by numerical simulation, with shields and collimators to limit the background due to waste radiations
Optimization of active neutron interrogation measurement by coupling with a method for correcting matrix effects
La masse fissile dans les fûts de déchets radioactifs remplis de résidus métalliques compactés (coques et embouts des combustibles usés) produits à l'usine de retraitement de La Hague est mesurée par interrogation neutronique active, sut l'atelier de compactage de coques et embouts (ACC). Dans le futur, des déchets anciens de cette nature mélangés à des résines échangeuses d'ions seront traités dans cette installation. Ces résines ont pour effet d'augmenter la propriété de modération des neutrons dans la matrice du fût, en comparaison des déchets mesurés actuellement. Dans ce contexte, une méthode de correction des effets de matrice basée sur l'utilisation de la mesure associée d'un moniteur de fût (compteur proportionnel à 3He) a été étudiée. La faisabilité de la méthode a dans un premier temps été étudiée sur la maquette R&D PROMETHEE 6, permettant de mettre en évidence d'une part une bonne corrélation entre le signal du moniteur et les effets de matrice et d'autre part une capacité du code de transport de particule MCNP a reproduire les performances expérimentales de la méthode. Par la suite, les performances finales de l'implantation de cette méthode sur le poste industriel 0-2 en entrée d'ACC ont été évaluées par simulation numérique. Les résultats des calculs concluent à une estimation de la masse fissile résiduelle avec une erreur d'environ un facteur 2, alors que celle-ci pourrait atteindre 2 décades sans la méthode de correction. Par ailleurs, l'analyse des résultats expérimentaux sur la mesure des fûts de la production courante en présence d'un moniteur de fût, établit une corrélation satisfaisante entre des propriétés physiques connues de la matrice pour ce type de déchets (modération et absorption) et le signal du moniteur, démontrant ainsi la fiabilité de l'approche proposée. En conséquence, cette méthode de correction sera implantée sur le poste industriel peut être préconisée pour d'autres dispositifs d'interrogation neutronique active.The fissile mass in radioactive waste drums filled with compacted metallic residues (spent fuel hulls and nozzles) produced at AREVA La Hague reprocessing plant is measured by neutron interrogation with the Differential Die-away measurement Technique, on the waste compaction facility (ACC). In the future, old hulls and nozzles mixed with ion-exchange resins will be measured. The ion-exchange resins increase neutron moderation in the matrix, compared to the waste measured in the current process. In this context, a matrix effect correction method based on a drum monitor (3He proportional counter) has been studied. The feasibility of the method was first performed with the R&D measurement cell PROMETHEE 6, showing a good correlation between the monitor signal and the matrix effect correction, and the capability of MCNP simulations to reproduce experiments and to estimate the performances of the proposed correction. Therefore, the industrial implementation of the method and the assessment of its final performances have been studied by numerical simulation. Calculations demonstrate that the method allows keeping the highest error on the measured fissile mass below roughly a factor of 2, while the matrix effect without correction ranges on 2 orders of magnitude. In addition, the analysis of experimental data from the current process shows a good correlation between known physical properties of the matrix (moderation and absorption) and the monitor signal, demonstrating the reliability of the proposed approach. According to these satisfactory results, this correction method will be implemented on the industrial station. More generally, this method could be applied to similar waste measurement systems
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
