1,720,962 research outputs found
Review of the current status of tooth whitening with the walking bleach technique
Internal bleaching procedures such as the walking bleach technique can be used for whitening of discoloured root-filled teeth. The walking bleach technique is performed by application of a paste consisting of sodium perborate- (tetrahydrate) and distilled water (3% H2O2), respectively, in the pulp chamber. Following a critical review of the scientific literature, heating of the mixture is contra-indicated as the risk of external cervical resorption and the formation of chemical radicals is increased by application of heat. An intracoronal dressing using 30% H2O2 should not be used in order to reduce the risk of inducing cervical resorption. This review provides advice based on the current literature and discusses how the walking bleach technique can lead to successful whitening of non-vital root-filled teeth without the risks of side-effects
Comparison of root canal preparation using RaCe and ProTaper rotary Ni‐Ti instruments
Aim To compare various parameters of root canal preparation using RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (Ni-Ti) instruments. Methodology Fifty extracted mandibular molars with mesial root canal curvatures between 20degrees and 40degrees were embedded in a muffle system. All root canals were prepared to size 30 using RaCe or ProTaper rotary instruments in low-torque motors with torque control and constant speed of 300 r.p.m. (ProTaper with ATR Tecnika, Advanced Technology Research, Pistoia, Italy; RaCe with EndoStepper, S.E.T., Olching, Germany). In both groups irrigation was performed with 2 mL NaOCl (3%) after each instrument size. Calcinase-Slide (lege artis, Dettenhausen, Germany) was used as a chelating agent with each instrument. The following parameters were evaluated: straightening of curved root canals, postoperative root canal cross-sections, safety issues and working time. Cleanliness of the root canal walls was investigated under the SEM using 5-score indices for debris and smear layer. Statistical analysis was performed using the following tests: Wilcoxon's test for straightening and working time was used (P < 0.05); Fisher's exact test for comparison of cross-sections and root canal cleanliness (P < 0.05). Results Both Ni-Ti systems maintained curvature well; the mean degree of straightening was less than 1degrees for both systems. Following preparation with RaCe, 49% of the root canals had a round or oval diameter and 50% an irregular diameter, ProTaper preparations resulted in a round or oval diameter in 50% of the cases. For debris, RaCe and ProTaper achieved 47 and 49% scores of 1 and 2, respectively; there was no significant difference. For smear layer, RaCe and ProTaper achieved 51 and 33% scores 1 and 2, respectively; no statistically significant differences were apparent for the coronal and middle sections of the root canals, but RaCe performed significantly better in the apical region (Fisher's exact test, P = 0.0392). Two roots lost working length with RaCe instruments, whilst ProTaper preparation resulted in two roots loosing working length and one fractured instrument. Mean working time was shorter for ProTaper (90.9 s) than for RaCe (137.6 s); the difference was significant (Wilcoxon's test, P = 0.011). Conclusions Both systems respected original root canal curvature well and were safe to use. Cleanliness was not satisfactory for both systems
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Enamel fluoride uptake of a novel water-based fluoride varnish
Aim of the in situ-study was to evaluate fluoride retention in sound and demineralised enamel after application of a novel water-based fluoride (0.12 % F) varnish Mirafluorid (Hager Et Werken, Germany) compared to the resin-based varnish (2.26 % F) Duraphat (Colgate, USA). Each five enamel specimens were prepared from 60 bovine incisors. In 150 of these specimens, incipient lesions were produced with acidic hydroxyethyl cellulose (pH 4.8; 72 h), 150 specimens were not demineralised. The samples were equally (n = 100) allotted to three groups (A: Mirafluord, B: Duraphat, and C: control). Each 80 specimens (40 demineralised and 40 sound) were varnished with either Mirafluorid or Duraphat or remained unfluoridated (controls). The other specimens were used for measuring base-tine fluoride content of the respective tooth. Each six specimens (three demineralised and three sound) were fixed in intraoral appliances worn for 5 days by 10 volunteers in three series (A-C). During the experiment, the samples were brushed twice daily with fluoridated toothpaste. KOH-soluble and structurally bound fluoride (0-30 and 31-60 mu m depth) was determined immediately, 1, 3 and 5 days after fluoridation. Fluoride uptake was calculated as compared to base-line content and statistically analysed. Immediately after fluoridation, uptake of KOH-soluble and structurally bound fluoride was similar for Mirafluorid and Duraphat in both demineralised and sound enamel. However, at day 1, 3 and 5 statistically significantly higher amounts of KOH-soluble and structurally bound fluoride were found in the samples treated with Duraphat. For Mirafluorid only the uptake for KOH-soluble fluoride and structurally bound fluoride in the first enamel layer (0-30 mu m) of the demineralised samples was significantly higher compared to the controls (C). It is concluded that the novel fluoride varnish Mirafluorid deposits less KOH-soluble and structurally bound fluoride on both demineralised and sound enamel compared to Duraphat under in situ-conditions. (c) 2004 Elsevier Ltd. All rights reserved
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
