1,720,968 research outputs found

    Efficacy and one-year outcomes of Luminor® paclitaxel-coated drug-eluting balloon in the treatment of popliteal artery atherosclerosis lesions

    No full text
    Purpose: Reporting outcomes with a new generation paclitaxel eluting balloon (Luminor®; iVascular, Vascular, S.L.U., Barcelona, Spain) in the popliteal district. Endovascular treatment of popliteal artery atherosclerotic disease is still debated without definitive evidences. Methods: From January to June 2019, patients’ data presenting popliteal artery atherosclerotic diseases and treated with the Luminor® (iVascular) drug eluting balloon (DEB) were prospectively collected. Critical limb ischemia (CLI) or severe claudication associated with popliteal artery stenosis >50% were the inclusion criteria. Measured outcomes were technical success, early and late results; including mortality, morbidity, symptoms recurrence, amputation, ankle-brachial index (ABI), survival, primary patency, secondary patency, freedom from restenosis. Median follow-up was 22.43 ± 4 (mean:21.58; IQR:20-24) months. Results: Of the 33 included patients, 28 (85%) were diagnosed with CLI, with a mean preoperative run-off score of 5.39 (r:0-10; SD:3) and a chronic popliteal occlusion in 21 (64%). Technical success was achieved in all cases. Perioperative mortality was observed in 1 (3%) patient and perioperative complications in 2 (6%). During the follow-up were reported 2 symptoms recurrence; a significant ABI increase (0.57; IQR:0.41-0.47 vs. 0.69; IQR:0.50-0.67; P < 0.01); 1 (3%) major and 2 (6%) minor amputations. Estimated 24 months survival, primary patency, secondary patency, and freedom from restenosis were 97%, 96.9%, 100%, and 93.8% respectively. Conclusions: In this prospective study, the use of the Luminor® (iVascular) was safe and effective in addressing atherosclerotic popliteal artery lesions. Larger studies with longer term-outcomes are required to assess the durability of this device in the popliteal artery

    Endovascular Treatment of Spontaneous Internal Carotid Artery Dissection with Proximal Embolic Protection Device

    No full text
    Background: The aim of this study was to report the feasibility and outcomes with the endovascular treatment of spontaneous internal carotid artery dissections (ICADs) using a proximal embolic protection device (EPD). Methods: This is a retrospective analysis of patients treated for spontaneous symptomatic ICAD using a proximal EPD from January 2017 to December 2018. Indication for treatment was the presence of neurologic symptoms. Early outcomes measured included technical success, perioperative mortality, and major cardiovascular or cerebrovascular complications. Late outcomes were recurrent neurologic symptoms, patency, and reinterventions. Results: A total of 4 male patients with ICAD were included. A preoperative cerebral computed tomography positive for cerebral ischemic events was reported in all cases. In 3 patients, the neurologic symptoms consisted of a transient ischemic attack; the remaining patient presented an amaurosis fugax and aphasia. In 2 patients, ICAD was associated with a carotid significant stenosis. In all patients, the reported approach was feasible with no complications and complete anatomic dissection resolution. At a mean follow-up of 18 months, all stents are patent and no restenosis recurrence or complications were registered. Conclusions: The use of proximal EPDs allowed the treatment of ICAD under flow arrest, minimizing the risk of stroke during the endovascular maneuvers. Larger series are required to validate this treatment strategy

    TEVAR and periscope graft technique to treatment of huge aneurysm of aortic isthmus: Case report

    Full text link
    Introduction: Thoracic endovascular aortic repair (TEVAR) has revolutionized the treatment of thoracic aortic aneurysms. Innovative techniques as chimney and periscope grafts can improve the outcomes of procedure. Herein, we report a case in emergency of huge Thoracic aortic aneurism. Presentation of case: An 86-year-old male with hypertension, diabetes mellitus, was referred to our hospital for chest pain. CT-angiography showed a huge aneurysm of aortic isthmus with signs of rupture. The patient was considered unfit for open surgery and an endovascular approach was chosen. This patient underwent endovascular repair with TEVAR, using the periscope graft technique to preserve patency in left subclavian artery (LSA). Discussion: Symptomatic ischemia from LSA coverage has been reported to occur in only a modest 6–10% of patients and is often sacrificed with impunity given coverage rates between 10 and 50%. In this case reported the lack of revascularization of LSA increased the risk of neurological manifestations or stroke. Periscope technique is feasible and safe to maintain perfusion to the subclavian artery, with a 93% primary patency at 2 years. Conclusions: Our experience using TEVAR with periscope graft technique as solution to address thoracic aneurysm of aortic isthmus was feasible and safe

    Outcome Analysis of Speed Gate Cannulation during Standard Infrarenal Endovascular Aneurysm Repair

    Full text link
    Background: Endovascular aortic repair (EVAR) is generally performed with bi/trimodular stent-grafts requiring retrograde contralateral gate cannulation (CGC). In the case of tricky CGC, an increased EVAR procedural time and radiation exposure have been reported. Herein, we compare the outcomes of conventional CGC and CGC using the speed gate cannulation (SGC) technique in standard EVAR for a propensity-matched cohort. Methods: A total of 371 patients were retrospectively analyzed. Inclusion criteria were fulfilled in 172 patients who underwent propensity score matching. Primary outcomes included operative time, CGC time, mean contrast medium, fluoroscopy time, and CGC fluoroscopy time. Results: After matching, 78 patients were included in each group (SGC vs. standard). Primary outcomes registered a significant reduction in CGC time (4 [1-6] vs. 8 [6-14] min; p = 0.001) and fluoroscopy time (12 [9-16] vs. 17 [12-25] min). Conclusions: In this preliminary experiment, the use of SGC was feasible with no significant registered postoperative complications. A significant reduction in contrast medium usage, radiation exposure, and CGC time was observed with the use of SGC. SGC is a simple adjunctive technique, and its use should be considered in standard EVAR, especially in emergency scenarios, where time is of the essence

    Mechanical rotational thrombectomy in long femoropopliteal artery and stent occlusion in COVID-19 patient: Case report

    Full text link
    Introduction: Coronavirus disease-19 (COVID-19) has been increasingly associated with thromboembolic complications. COVID-19 infection has a thrombogenic potential for stents. Herein, we report a case of stent thrombosis in diabetic obese patient COVID-19 positive where was previously released a Multilayer Flow Modulator stent (MFM) for large popliteal aneurysm. Case report: A 78-year-old male was referred to our hospital for fever and acute pain in the left leg. At history, the same patient had endovascular procedure for a large symptomatic popliteal aneurysm, treated through release of three MFM. The pulmonary CT scan showed COVID-19 infection with confirm of rhino-laryngeal swab. Duplex ultrasound and CT-angiography showed complete thrombosis of stents. The treatment consisted of mechanical thrombectomy using an 8Fr catheter Rotarex plus release of Vibahn stent-graft. Discussion: COVID-19 patients can present arterial occlusion. In literature are not reported cases about thrombosis peripheral stent. Minimally invasive approaches in redo-procedure reduce risk of infection. Rotarex device was used in revascularization of acute and subacute iliac and femoropopliteal arteries. The goal is to have a debulking, to avoid an incomplete deployment of stent-graft. In our precedent experience, MFM and stent-graft to treatment of popliteal aneurism were safe. It is important to monitor these patients for early identification of failure and rapprochement. In this case, the COVID-19 infection was determinant in promoting thrombosis. Conclusions: COVID-19 increases risk of thrombosis stent. In our experience debulking through Rotarex and stenting, were decisive factors for revascularization and limb salvage

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair

    No full text
    Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath and J-tip wire with pigtail catheter are retracted until the CLG opening level, maintaining the stiff "buddy" wire in position to support the 12 fr sheath, maintaining its distal opening close to the contralateral gate opening to achieve easy cannulation. Results: Retrospective analysis of video archive from July 2016 to February 2018 evidenced 55 recorded EVAR cases. All CLG cannulations were obtained with Standard J-tip or Terumo Glidewire wires and with Pig-Tail or Berenstein catheters. Technical success was 100 %. Mean fluoroscopy time to accomplish CLG cannulation was 37.6 33 (range 1-105) seconds. The aortic carrefour angulation on coronal axis strongly correlates with cannulation time p = <.001, with longer cannulation time for higher carrefour angulations on coronal axis (Pearson correlation coefficient 0.47). Conclusions: The use of 12 fr sheath with parallel wire introduction technique, appears to be a safe and reliable tool to facilitate CLG cannulation during EVAR procedures

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore