1,720,995 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve
Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation site morphology, size and dynamics, only
about 15 per cent of cases are suitable for current devices. In order to increase the number of patients who could benefit from minimally invasive procedures, a new valved stent graft for percutaneous implantation has been designed recently. In
this study, patient-specific computational analyses have been applied to investigate the suitability of new device designs, using real data from 62 patients who had undergone surgical pulmonary valve replacement. Magnetic resonance images of these patients before surgery were elaborated using imaging post-processing software to reconstruct the three-dimensional volume of each patient’s implantation site. Three stent designs were created and tested in these patient outflow tracts using finite-element simulations: stent graft SG1 resembles the first device tested in animals; stent graft SG2 is a custom device tailored for a specific patient morphology; and stent graft
SG3 represents a hypothetical larger device. The three devices showed an implantation success rate of 37 per cent, 42 per cent and 63 per cent, respectively. Using patientspecific simulations, we have shown that a percutaneous approach with these new
devices may be possible for many patients who are currently referred for surgery.
Furthermore, when the new devices become available, the methodologies described may help clinicians in the decision-making process, by enabling virtual implantation prior to
the actual procedure
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation
Percutaneous replacement of the pulmonary valve is a recently developed interventional technique which involves the implantation of a valved stent in the pulmonary trunk.
It relies upon careful consideration of patient anatomy for both stent design and detailed procedure planning. Medical imaging data in the form of two-dimensional scans and threedimensional
interactive graphics offer only limited support for these tasks. The paper reports the results of an experimental investigation on the use of arterial models built by rapid prototyping techniques. An analysis of clinical needs has helped to specify proper requirements for such model properties as cost, strength, accuracy, elastic compliance, and optical transparency.
Two different process chains, based on the fused deposition modelling technique and on the vacuum casting of thermoset resins in rubber moulds, have been tested for prototype fabrication. The use of anatomical models has allowed the cardiologist’s confidence in patient selection, prosthesis fabrication, and final implantation to be significantly improved
Patient Specific Finite Element Analysis Results in More Accurate Prediction of Stent Fractures: Application to Percutaneous Pulmonary Valve Implantation.
Stent fracture is a recognised complication following device implantation. Magnetic resonance data from a patient who underwent percutaneous pulmonary valve implantation (PPVI) and had subsequent stent fractures was used to create a finite element (FE) model of the patient's implantation site. Simulated expansion of the PPVI stent into this right ventricular outflow tract (RVOT) geometry was compared with free expansions of the PPVI stent up to a uniformly deployed configuration (conventional method employed in bench testing protocols), using FE analysis. PPVI biplane fluoroscopy images from the same patient were used to reconstruct the 3D shape and deformation of the stent in-situ and verify the FE geometrical results. Asymmetries were measured in all 3 orthogonal directions, in early systole and diastole. Although a simplified FE modelling of stent/implantation site interaction was adopted, this analysis gave useful information about the influence of the RVOT on the final geometry and mechanical performance of the stent. When deployed into the RVOT, the FE stent showed a non-uniform shape, similar to the geometry seen in the "real" fluoroscopy reconstructed stent, where the most expanded cells corresponded to the fracture locations. This asymmetrical geometry, when compared to the free-expanded stent, resulted in higher stresses in the portion of the stent where fractures occurred. Furthermore, fatigue fractures that were not predicted in the free-deployed stents, developed in the asymmetrically expanded device. In conclusion, the interaction between the PPVI device and the patient's RVOT is likely to be the crucial factor involved with this undesired event. Copyright 2009 Elsevier Ltd. All rights reserved
- …
