1,721,052 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Time-efficient methods for non-invasive brain blood flow imaging using arterial spin labelling MRI
Accurate knowledge of brain tissue perfusion and clear visualisation of cerebral arteries are of great interest for the diagnosis and research of a range of diseases and conditions such as stroke, dementia, Moyamoya, and cancer, as well as in drug development. 15O-H20 PET imaging is considered the gold standard for measuring cerebral blood flow (CBF), while contrast-enhanced x-ray digital subtraction angiography is the gold standard for visualising cerebral arteries. However, both methods use ionising radiation and injectable contrast agents so carry some risks to the patient and are not appropriate for longitudinal monitoring or research.
There is growing interest in arterial spin labelling (ASL) magnetic resonance imaging (MRI), which uses magnetically labelled blood as an endogenous and freely diffusible tracer and can be flexibly used to visualise the arterial tree as well as to measure CBF. However, ASL is an intrinsically low SNR technique, requiring signal averaging and long scan times.
The main aim of this thesis is to improve the time-efficiency of ASL MRI perfusion and angiographic scans, increasing the accuracy and SNR of CBF measurements and vessel depiction in clinically relevant scan times.
First, a statistical framework was developed and validated for optimising multi- delay ASL perfusion protocol timings to improve the accuracy of CBF and arterial transit time measurements. This flexible framework can be targeted to improve the accuracy of specific parameters and provides a more informed method for designing ASL protocols.
Next, this framework was used to optimise and objectively compare a range of existing pseudo-continuous ASL (PCASL) perfusion protocol designs, including time- encoded preparations, from the literature and to explore novel protocol designs. These comparisons allowed the advantages and disadvantages of each approach to be explored, and recommendations about the best ASL experimental designs to be made.
Finally, the benefits of time-encoded PCASL preparations for ASL angiography were investigated. Angiography visualises the pass-through of labelled blood, in contrast to perfusion imaging which relies on the accumulation of labelled blood in tissue, and so the short label durations used in time-encoded PCASL have a greatly reduced impact on the magnitude of the ASL signal. A variable flip-angle approach was also used to remove signal discontinuities and demonstrate a significant SNR improvement over conventional PCASL angiography.</p
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Optimisation of vessel-selective magnetic resonance perfusion imaging and angiography
The diagnosis and treatment of cerebrovascular disease, such as stroke and vascular lesions in the brain, requires knowledge of the status of brain tissue and cerebral arteries. Perfusion imaging and angiography offer information on blood flow to the tissue and through the brain-feeding arteries. A variety of imaging modalities exist to assess brain haemodynamics, including measures of cerebral blood flow and other parameters, however many of these are invasive and/or involve the use of contrast agents toxic to certain patient populations.
One non-invasive magnetic resonance imaging alternative for perfusion imaging and angiography, which also provides vessel specific blood flow information, is vessel-encoded pseudocontinuous arterial spin labelling (VEPCASL). VEPCASL uses the blood as an endogenous tracer and can magnetically label the blood from different arteries of interest. The combination of VEPCASL with different imaging strategies can provide a map of the vascular perfusion territories in the brain, or dynamic information on blood flow through the cerebral arteries.
The work in this thesis seeks to optimise and develop the encoding process of VEPCASL and accompanying angiographic readouts. Firstly, a rapid and automated method for calculating a minimal number of signal-to-noise ratio (SNR) efficient encodings, for any number and arrangement of vessels, was developed. Its use resulted in improved SNR in perfusion territories fed by more complicated vessel arrangements in the labelling plane. The labelling efficiency of VEPCASL, and its non-vessel-selective equivalent, PCASL, is affected by the presence of magnetic field inhomogeneities in the labelling plane. Consequently, a correction for phase offsets was introduced into the calculation of the optimised encodings. These encodings enabled the recovery of SNR in perfusion territories for PCASL and VEPCASL when phase offsets were present at the labelled arteries.
As current VEPCASL angiography methods are relatively slow to acquire, an accelerated readout was developed to acquire two-dimensional vessel-selective dynamic angiograms in approximately one minute. A radial k-space trajectory was found to offer the best vessel definition and SNR. Three-dimensional (3D) angiograms provide the most detailed view of the cerebral vasculature for use in diagnosis and treatment of cerebrovascular disease. A 3D radial readout was optimised to acquire vessel-selective dynamic angiograms. These angiograms offer information on the structure of the vascular tree and how it is fed by the major arteries in the neck.
The techniques developed here aim to increase the clinical viability and applicability of VEPCASL perfusion imaging and angiography. It is hoped that the techniques herein could be used in patient populations to add to and improve the diagnostic information available.</p
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
