170,307 research outputs found
Linking entanglement detection and state tomography via quantum 2-designs
We present an experimentally feasible and efficient method for detecting entangled states with measurements that extend naturally to a tomographically complete set. Our detection criterion for bipartite systems with equal dimensions is based on measurements from subsets of a quantum 2-design, e.g. mutually unbiased bases or symmetric informationally complete states, and has several advantages over standard entanglement witnesses. First, as more detectors in the measurement are applied, there is a higher chance of witnessing a larger set of entangled states, in such a way that the measurement setting converges to a complete setup for quantum state tomography. Secondly, our method is twice as effective as standard witnesses in the sense that both upper and lower bounds can be derived. Thirdly, the scheme can be readily applied to measurement-device-independent scenarios
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Mitomycin C in highly myopic eyes - Author reply
Ophthalmology. 2005 Feb;112(2):208-18; discussion 219.
Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes.
Gambato C, Ghirlando A, Moretto E, Busato F, Midena E.
SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy.
Abstract
PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes.
DESIGN: Prospective, double-masked, randomized clinical trial.
PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia.
METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months).
MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH.
RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively).
CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK.
Comment in
Ophthalmology. 2006 Feb;113(2):357; author reply 357-8
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Detecting entanglement can be more effective with inequivalent mutually unbiased bases
Mutually unbiased bases (MUBs) provide a standard tool in the verification of quantum states, especially when harnessing a complete set for optimal quantum state tomography. In this work, we investigate the detection of entanglement via inequivalent sets of MUBs, with a particular focus on unextendible MUBs. These are bases for which an additional unbiased basis cannot be constructed and, consequently, are unsuitable for quantum state verification. Here, we show that unextendible MUBs, as well as other inequivalent sets in higher dimensions, can be more effective in the verification of entanglement. Furthermore, we provide an efficient and systematic method to search for inequivalent MUBs and show that such sets occur regularly within the Heisenberg-Weyl MUBs, as the dimension increases. Our findings are particularly useful for experimentalists since they demonstrate that a clever selection of MUBs allows for entanglement detection with fewer measurements
A Multi-Language Comparison of Influences on Author Verification using Character N-Grams
We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc
A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C
Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (> 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
How many mutually unbiased bases are needed to detect bound entangled states?
From a practical perspective it is advantageous to develop methods that verify entanglement in quantum states with as few measurements as possible. In this paper we investigate the minimal number of mutually unbiased bases (MUBs) needed to detect bound entanglement in bipartite (d×d)-dimensional states, i.e. entangled states that are positive under partial transposition. In particular, we show that a class of entanglement witnesses (EWs) composed of MUBs can detect bound entanglement if the number of measurements is greater than d/2+1. This is a substantial improvement over other detection methods, requiring significantly fewer resources than either full quantum state tomography or measuring a complete set of d+1 MUBs. Our approach is based on a partial characterisation of the (non-)decomposability of EWs. We show that non-decomposability is a universal property of MUBs, which holds regardless of the choice of complementary observables, and we find that both the number of measurements and the structure of the witness play an important role in the detection of bound entanglement
Toxic equivalency factors (TEFs) after acute oral exposure of azaspiracid 1, 122 and 123 in mice
Azaspiracids (AZAs) are marine algal toxins that can be accumulated by edible shellfish to cause a foodborne gastrointestinal poisoning in humans. In the European Union, only AZA1, 122 and 123 are currently regulated and their concentration in shellfish is determined through their toxic equivalency factors (TEFs) derived from the intraperitoneal lethal potency in mice. Nevertheless, considering the potential human exposure by oral route, AZAs TEFs should be calculated by comparative oral toxicity data. Thus, the acute oral toxicity of AZA1, 122 and 123 was investigated in female CD-1 mice treated with different doses (AZA1: 135\u20131100 \u3bcg/kg; AZA2 and AZA3: 300\u20131100 \u3bcg/kg) and sacrificed after 24 h or 14 days. TEFs derived from the median lethal doses (LD50) were 1.0, 0.7 and 0.5, respectively for AZA1, 122 and 123. In fact, after 24 h from gavage administration, LD50s were 443 \u3bcg/kg (AZA1; 95% CL: 350 12561 \u3bcg/kg), 626 \u3bcg/kg (AZA2; 95% CL: 430 12911 \u3bcg/kg) and 875 \u3bcg/kg (AZA3; 95% CL: 757 121010 \u3bcg/kg). Mice dead more than 5 h after the treatment or those sacrificed after 24 h (doses: 65175 \u3bcg AZA1/kg, 65500 \u3bcg AZA2/kg and 65600 \u3bcg AZA3/kg) showed enlarged pale liver, while increased serum markers of liver alteration were recorded even at the lowest doses. Blood chemistry revealed significantly increased serum levels of K+ ions ( 65500 mg/kg), whereas light microscopy showed tissue changes in the gastrointestinal tract, liver and spleen. No lethality, macroscopic, tissue or haematological changes were recorded two weeks post exposure, indicating reversible toxic effects. LC\u2013MS/MS analysis of the main organs showed a dose-dependency in gastrointestinal absorption of these toxins: at 24 h, the highest levels were detected in the stomach and, in descending order, in the intestinal content, liver, small intestine, kidneys, lungs, large intestine, heart as well as detectable traces in the brain. After 14 days, AZA1 and AZA2 were still detectable in almost all the organs and intestinal content.Peer reviewed: YesNRC publication: Ye
A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration
Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
- …
