1,720,989 research outputs found

    Adoption of Splenic Enhancement to Time and Trigger the Late Hepatic Arterial Phase During MDCT of the Liver: Proof of Concept and Clinical Feasibility

    No full text
    OBJECTIVE The purpose of this study was to prospectively investigate the clinical feasibility of adopting splenic enhancement for timing and triggering the acquisition of late hepatic arterial phase images during multiphasic liver MDCT for assessment of hypervascular tumors. SUBJECTS AND METHODS Forty-eight patients (33 men, 15 women; median age, 59 years; chronic liver disease, 23 patients; portal venous hypertension, 17 patients) with a total of 81 hypervascular liver tumors underwent liver MDCT by random assignment to one of two scanning protocols. Scanning delay for the late hepatic arterial phase was determined by assessment of time-to-peak splenic enhancement (splenic-triggering protocol) or aortic enhancement (aortic-triggering protocol). Acquisition timing, vascular attenuation, liver attenuation and homogeneity, signal-to-noise ratio, tumor-to-liver contrast, and tumor-to-liver contrast-to-noise ratio were compared. Two blinded independent observers used Likert scales to score timing adequacy (3-point scale), diagnostic confidence (5-point scale), and per lesion conspicuity (4-point scale) for hypervascular tumor detection. RESULTS The splenic- and aortic-triggering protocols had significant differences in mean late hepatic arterial phase imaging timing (splenic, 36 ± 6 seconds; aortic, 32 ± 3 seconds; p = 0.010). Images obtained with the splenic-triggering protocol had significantly better observer-based judgment of adequacy (splenic, 2.04; aortic, 1.58; p = 0.002). Mean attenuation and signal-to-noise ratios from liver and portal vein were significantly higher with the splenic- than with the aortic-triggering protocol (p < 0.0001). The splenic-triggering protocol was associated with significant improvement in homogeneity of liver attenuation (p < 0.0001). Although the splenic-triggering protocol was associated with significantly higher lesion conspicuity than was the aortic-triggering protocol (p = 0.022), there was no significant difference in tumor detection rate. CONCLUSION Our results provide a clinical foundation for and proof of principle that the adoption of splenic enhancement renders an optimal temporal window for late hepatic arterial phase imaging during MDCT of the liver for assessment of hypervascular tumors

    Negative biopsy of focal hepatic lesions: Decision tree model for patient management

    No full text
    OBJECTIVE. The purpose of this study was to investigate patient- and procedure-related variables affecting the false-negative rate of ultrasound (US)-guided liver biopsy and to develop a standardized patient-tailored predictive model for the management of negative biopsy results. MATERIALS AND METHODS. We retrospectively included 389 patients (mean age ± SD, 62 ± 12 years old) who had undergone US-guided liver biopsy of 405 liver lesions between January 1, 2013, and June 30, 2015. We collected multiple patient- and procedure-related variables. By comparing pathology reports of biopsy and the reference standard (further histology or imaging follow-up), we were able to categorize the biopsy results as true-positive, true-negative, and false-negative. Diagnostic accuracy and diagnostic yield were measured. Univariate and multivariate analyses were performed to identify variables predicting false-negative results. A standardized patient-tailored predictive model of false-negative results based on a decision tree was fitted. RESULTS. Diagnostic accuracy and diagnostic yield were 93.8% (380/405) and 89.4% (362/405), respectively. The false-negative rate was 6.5% (25/387). Predictive variables of false-negative results at univariate analysis included body mass index, lesion size, sample acquisition techniques, and immediate specimen adequacy. The only independent predictors at multivariate analysis were patient age and Charlson comorbidity index. By combining lesion size and location with patient age and history of malignancy, we developed a decision tree model that predicts false-negative results with high confidence (up to 100%). CONCLUSION. False-negative results are not negligible at US-guided liver biopsy. The combination of selected lesion- and patient-specific variables may help predict when aggressive management is warranted in patients with likely false-negative results

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used

    Effect of a Noise-Optimized Second-Generation Monoenergetic Algorithm on Image Noise and Conspicuity of Hypervascular Liver Tumors: An In Vitro and In Vivo Study

    No full text
    The purpose of this study is to investigate whether the reduction in noise using a second-generation monoenergetic algorithm can improve the conspicuity of hypervascular liver tumors on dual-energy CT (DECT) images of the liver
    corecore