1,720,956 research outputs found

    Hearing threshold estimation by auditory steady state responses (ASSR) in children

    No full text
    Hearing threshold identification in very young children is always problematic and challenging. Electrophysiological testing such as auditory brainstem responses (ABR) is still considered the most reliable technique for defining the hearing threshold. However, over recent years there has been increasing evidence to support the role of auditory steady-state response (ASSR). Retrospective study. Forty-two children, age range 3-189 months, were evaluated for a total of 83 ears. All patients were affected by sensorineural hearing loss (thresholds >= 40 dB HL according to a click-ABR assessment). All patients underwent ABRs, ASSR and pure tone audiometry (PTA), with the latter performed according to the child's mental and physical development. Subjects were divided into two groups: A and B. The latter performed all hearing investigations at the same time as they were older than subjects in group A, and it was then possible to achieve electrophysiological and PTA tests in close temporal sequence. There was no significant difference between the threshold levels identified at the frequencies tested (0.25, 0.5, 1, 2 and 4 kHz), by PTA, ABR and ASSR between the two groups (Mann Whitney U test, p < 0.05). Moreover, for group A, there was no significant difference between the ASSR and ABR thresholds when the children were very young and the PTA thresholds subsequently identified at a later stage. Our results show that ASSR can be considered an effective procedure and a reliable test, particularly when predicting hearing threshold in very young children at lower frequencies (including 0.5 kHz)

    Neonatal newborn hearing screening: four years' experience at Ferrara University Hospital (CHEAP project): part 1.

    No full text
    The Child Hearing Early Assessment Programme (CHEAP) regional project, was a combined departmental approach (Audiology, Neonatology) of the University Hospital of Ferrara, aimed at identifying neonatal hearing impairment and defining early intervention strategies. Aims of this project have been: (i) construction of a neonatal screening programme using evoked otoacoustic emission and auditory brainstem responses; (ii) the calculation of a precise estimate of cost-benefits for every child tested; (iii) the development of an information flow instrument (database) for the storage of data and the statistical analysis of the results. The present report refers only to the results of the project related to the otoacoustic emission data from well-babies and intensive care unit residents. In the period January 2000-December 2004, 4269 full-term newborns and 654 Neonatal Intensive Care Unit babies were tested at the Neonatology Department. The cost of the Universal Neonatal Hearing Screening was estimated at Euro 9.20 per child, considering the use of the ILO-292 apparatus, and Euro 8.28 per child in the case of an automatic screener. In this screening model, the initial hardware costs can be re-iterated into budget in a period of two years, if 1000 children per year are tested

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Hearing Loss in Children: Clinical-Epidemiological Data from Two Different Provinces of the Same Region

    Full text link
    Background: In many countries, neonatal hearing screening programs (NHS) have been available for many years; however, because of the presence of hearing loss at late onset, early hearing detection programs (EHDP) have been implemented. The aim of this study was to evaluate all cases of infantile hearing loss under the care of two different provinces of a regional health service since the introduction of NHS. Methods: Clinical data (the presence of audiological risk factors, age at which children are placed under the care of health service, entity of hearing loss, treatment, and exposure to bilingualism) were retrospectively collected during the period from 1 January 2012 to 31 December 2018, starting from the IT management system used in all of the regional neuropsychiatric services. Results: In total, 124 children were included—116 cases failed the screening, 1 case had an untraceable result, and 7 cases (5.6%) had hearing screening that passed. Most of the children were placed under the care of a neuropsychiatric infantile and adolescence (NPIA) service within the first year of life. The main differences across the two provinces concerned the percentages of audiological risk factors and the number of unilateral hearing loss cases. Conclusion: In order to plan and manage hearing rehabilitation programs for children in the best way, it is very important to know the local clinical-epidemiological features of the population

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore