1,720,960 research outputs found

    Transcatheter cerebral embolic protection in open heart surgery: our initial experience in Ancona, Italy

    No full text
    BACKGROUND: Neurological events after cardiac surgery or transcatheter aortic valve implantation (TAVI) have a dramatic effect on patients' prognosis. Recent development of transcatheter cerebral protection systems aims to reduce their incidence, even if their use is currently limited to TAVI. Here we report our initial experience with transcatheter cerebral protection devices used in patients at high brain embolic risk undergoing cardiac surgery. METHODS: Between December 2018 and March 2020, at the Cardiac Surgery Unit of Lancisi Cardiovascular Center in Ancona, Italy, 9 patients (mean age 77 years; median EuroSCORE II: 2.2%) underwent cardiac surgery using a transcatheter cerebral protection system (Sentinel, Claret Medical, Santa Rosa, CA, USA). In all cases, a preoperative computed tomography scan highlighted the presence of severely calcified ascending aorta. RESULTS: The brain protection system was successfully implanted in all patients. Total time for device implantation and removal was less than 10 min in all cases. Four patients underwent aortic valve replacement, 2 mitral surgery, whereas 3 received combined valve surgery. Calcified debris were found within filters in 100% of patients. Postoperatively, there were neither neurological events nor major complications. CONCLUSIONS: In our experience, transferring transcatheter brain protection techniques and technologies to cardiac surgery allowed us (with excellent results) to avoid palliative percutaneous or medical management in patients with severe aortic calcifications. Waiting for more solid evidence, we believe that our example supports the concept of hybrid surgery as a therapeutic approach capable of extending traditional surgical indications with improved patients' outcomes

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    One-year outcomes of surgical aortic valve replacement: A single, high-volume center experience

    No full text
    Background. The introduction of transcatheter aortic valve replacement (AVR) mandates attention to outcomes after surgical AVR (SAVR). The aim of this study was to assess 1-year outcomes in a contemporary large cohort of patients undergoing AVR. Methods. Data from 520 patients who underwent isolated SAVR between October 2016 and April 2019 were prospectively collected. Results. The mean age of the study population was 72.8 ± 10.1 years and the average EuroSCORE II was 1.8 ± 1.5%. SAVR was performed using minimally invasive approaches (MI-AVR) in 306 patients (58.9%). However, the rate of MI-AVR considerably increased over the observational period from 47.9% to 86.7% (p<0.001). MI-AVR patients received rapid deployment valves in 40% of cases, minimally invasive extracorporeal circulation system in 34.4% and ultra fast track anesthetic management with table extubation in 38.2%. Overall 30-day mortality was 0.4% (n=2). The rates of postoperative stroke and atrioventricular block requiring pacemaker implantation were 0.6% (n=3) and 3.8% (n=20), respectively. At 1 year, the estimated survival, stroke and rehospitalization rates were 97.3%, 1% and 4.5%, respectively. Overall, the estimated incidence of the composite endpoint - death, stroke and rehospitalization - was 7%. Conclusions. Contemporary SAVR in a high-volume center yields excellent clinical outcomes with very low mortality and morbidity. In this setting, the extensive use of minimally invasive approaches combined with the modern techniques and technologies demonstrated to improve clinical outcomes and increase patient and family satisfaction

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore