1,720,970 research outputs found
Use of wearable systems for the detection of chest-abdominal wall movement aimed at respiratory monitoring in sport: a scoping review on available data
There is a significant request for wearable systems for vital signs and athletic performance monitoring during sport practice, both in professional and non-professional fields. Respiratory rate is a rather neglected parameter in this field, but several studies show that it is a strong marker of physical exertion. The aim of the present scoping review is to evaluate the number and kind of existing studies on wearable technologies for the analysis of the chest wall movement for respiratory monitoring in sport and fitness. The review included studies investigating the use of contact-based wearable techniques for the detection of chest wall movement for respiratory monitoring during professional or amateur sport, during fitness and physical activity. The search was conducted on PubMed/Medline, Scopus and Google Scholar electronic databases using keywords. Data extracted were entered into a Microsoft Excel spreadsheet by the leading author and then double-checked by the second author. A total of 25 descriptive studies met the inclusion criteria. Few studies on small number of athletes were found, technologies were often evaluated without a reference system, data on participants are sometimes missing. To date, we are not able to draw conclusions on which is the best and most reliable device to use during sport practice
Validation and assessment of a posture measurement system with magneto-inertial measurement units
Inappropriate posture and the presence of spinal disorders require specific monitoring systems. In clinical settings, posture evaluation is commonly performed with visual observation, electrogoniometers or motion capture systems (MoCaps). Developing a measurement system that can be easily used also in non-structured environments would be highly beneficial for accurate posture monitoring. This work proposes a system based on three magneto-inertial measurement units (MIMU), placed on the backs of seventeen volunteers on the T3, T12 and S1 vertebrae. The reference system used for validation is a stereophotogrammetric motion capture system. The volunteers performed forward bending and sit-to-stand tests. The measured variables for identifying the posture were the kyphosis and the lordosis angles, as well as the range of movement (ROM) of the body segments. The comparison between MIMU and MoCap provided a maximum RMSE of 5.6° for the kyphosis and the lordosis angles. The average lumbo-pelvic contribution during forward bending (41.8 ± 8.6%) and the average lumbar ROM during sit-to-stand (31.8 ± 9.8° for sitting down, 29.6 ± 7.6° for standing up) obtained with the MIMU system agree with the literature. In conclusion, the MIMU system, which is wearable, inexpensive and easy to set up in non-structured environments, has been demonstrated to be effective in posture evaluation
Optoelectronic plethysmography to evaluate the effect of posture on breathing kinematics in spinal cord injury: a cross sectional study
BACKGROUND: Spinal cord injured patients often suffer from respiratory muscles impairment. Spirometry studies showed that in supine position vital capacity increases in such patients since diaphragm increases its inspiratory excursion. To our opinion, however, respiratory kinematics in spinal cord injured patients is disadvantaged in supine position. AIM: To evaluate the effect of posture (sitting and supine) on respiratory kinematics in chronic spinal cord injured patients using optoelectronic plethysmography. DESIGN: Cross-sectional study. SETTING: Outpatients referring to the Movement Analysis Laboratory of a Physical and Rehabilitation Medicine Unit. POPULATION: Twenty chronic spinal cord injured patients (9 tetraplegics, with lesional level ranging from C3 to C7 and 11 paraplegics with lesional level ranging from T1 to T8) and twenty healthy subjects matched for gender, age and smoking habits. METHODS: All subjects underwent optoelectronic evaluation in sitting and supine position during quiet breathing and hyperventilation. Additional trials were performed to derive respiratory functional parameters (vital capacity and forced expiratory volume in the first second) in sitting and in supine position. Compartmental volumes and respiratory functional parameters were analyzed by means of analysis of variance. Post-hoc comparisons by means of t-tests were performed to analyze differences within and between study groups (spinal cord injured patients and healthy subjects, paraplegics and tetraplegics). Phase angle analysis and Konno and Mead diagrams were performed to evaluate if thoracic and abdominal compartments were moving in synchrony during breathing and the results were compared by paired t-tests. RESULTS: Supine position increases vital capacity and forced expiratory volume in the first second. This could be due to the more favorable length of the diaphragm in supine than in sitting position. However in such posture the phase shift between thorax and abdomen during breathing increases. CONCLUSION: Optoelectronic plethysmography measurements showed that even if in supine position there is an improvement in respiratory functional parameters, the respiratory kinematics of the chest wall is disadvantaged. CLINICAL REHABILITATION IMPACT: Our study suggests that the use of abdominal binders could reproduce in sitting position the positive effect of supine position on diaphragm, that could work at a more favorable point of its length tension curve
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
