1,721,102 research outputs found
Switchable LED-based laparoscopic multispectral system for rapid high-resolution perfusion imaging
SIGNIFICANCE: Multispectral imaging (MSI) is an approach for real-time, quantitative, and non-invasive tissue perfusion measurements. Current laparoscopic systems based on mosaic sensors or filter wheels lack high spatial resolution or acceptable frame rates.AIM: To develop a laparoscopic system for MSI-based color video and tissue perfusion imaging during gastrointestinal surgery without compromising spatial or temporal resolution.APPROACH: The system was built with 14 switchable light-emitting diodes in the visible and near-infrared spectral range, a 4K image sensor, and a 10 mm laparoscope. Illumination patterns were created for tissue oxygenation and hemoglobin content monitoring. The system was calibrated to a clinically approved laparoscopic hyperspectral system using linear regression models and evaluated in an occlusion study with 36 volunteers.RESULTS: The root mean squared errors between the MSI and reference system were 0.073 for hemoglobin content, 0.039 for oxygenation in deeper tissue layers, and 0.093 for superficial oxygenation. The spatial resolution at a working distance of 45 mm was 156 μm. The effective frame rate was 20 fps.CONCLUSIONS: High-resolution perfusion monitoring was successfully achieved. Hardware optimizations will increase the frame rate. Parameter optimizations through alternative illumination patterns, regression, or assumed tissue models are planned. Intraoperative measurements must confirm the suitability during surgery.</p
MR-guided focused ultrasound application for moving target tumor ablation in abdominal area:coil selection
Background: Magnetic Resonance Imaging (MRI)-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive thermal ablation method utilizing high-intensity focused ultrasound (HI-FU) energy for tissue ablation under MRI with real-time thermal mapping. Ablating to a dynamic target as in the liver is very challenging, requiring approval. A novel quality-assured liver tumor ablation system has been proposed for clinics. The paper reports the evaluation of conventional and new MR-receiving coils.Purpose: To evaluate the suitability of MR coils as part of the MRgFUS treatment system for liver, while simulating breathing motion in pre-clinical settings.Material and Methods: The novel software communicates with the MR scanner and the transducer. To monitor the temperature via proton resonance frequency (PRF) methodology echo planar imaging (EPI) sequence was used while the algorithms of static, static and dynamic tracking were tested with sonications of 100 W for 30 s on tissue-mimicking phantoms. Different coil sets were used to assess the performance of the system for fitness for dynamic thermometry. Finally, in vivo experiments were performed over a porcine model.Results: Single-loop four-channel Duoflex and Gem coils provided adequate signal-to-noise ratio and contrast with consistent thermal readings. Body array coils showed severe loss of signal in dynamic cases since the integration of tracking algorithm causes low efficiency.Conclusion: Body array coils are unsuitable for MRgFUS of the liver due to signal loss. The dedicated coil set with a single loop around the FUS transducer combined with four-channel arrays might be the best option for liver treatment using dynamic MRgFUS applications
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Image stitching for real-time laparoscopic hyperspectral imaging
Abstract Hyperspectral imaging (HSI) shows significant promise in the medical field for tissue detection and perfusion assessment. To extend its application to intraoperative diagnosis, laparoscopic cameras combining a high resolution color video and simultaneous HSI were developed. Spatial scanning in these cameras is performed through a push-broom motor driving a line-scan spectrograph. However, long acquisition times and the necessity of absolute immobility for patient and operator currently limit its usability in the operating room. To provide a hyperspectral acquisition alternative to the traditional push-broom motor approach, we have developed an HSI stitching pipeline that enables freehand line scanning. Our method utilizes the dual recording capability of the camera, which has both an RGB and an HSI sensor. It applies the transformations observed in the RGB video to the corresponding HSI data, then seamlessly merges this data to create a coherent panorama. This allows operators to visualize hyperspectral data as an incrementally expanding overlay on the color video by scanning the scene with the laparoscope. The pipeline evaluation confirms the generation of globally consistent and well-interpretable panoramas with a high level of detail. The registration error is not only comparable to the push-broom method but also corresponds to a real-world error of less than 0.4 mm in 95 % of the cases. Therefore, the proposed method enhances the practicability of intraoperative hyperspectral imaging by providing a dynamic, video-like experience of HSI visualizations
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
