1,721,010 research outputs found

    Exploring Temporal Patterns in Classifying Frustrated and Delighted Smiles

    Get PDF
    We create two experimental situations to elicit two affective states: frustration, and delight. In the first experiment, participants were asked to recall situations while expressing either delight or frustration, while the second experiment tried to elicit these states naturally through a frustrating experience and through a delightful video. There were two significant differences in the nature of the acted versus natural occurrences of expressions. First, the acted instances were much easier for the computer to classify. Second, in 90 percent of the acted cases, participants did not smile when frustrated, whereas in 90 percent of the natural cases, participants smiled during the frustrating interaction, despite self-reporting significant frustration with the experience. As a follow up study, we develop an automated system to distinguish between naturally occurring spontaneous smiles under frustrating and delightful stimuli by exploring their temporal patterns given video of both. We extracted local and global features related to human smile dynamics. Next, we evaluated and compared two variants of Support Vector Machine (SVM), Hidden Markov Models (HMM), and Hidden-state Conditional Random Fields (HCRF) for binary classification. While human classification of the smile videos under frustrating stimuli was below chance, an accuracy of 92 percent distinguishing smiles under frustrating and delighted stimuli was obtained using a dynamic SVM classifier.MIT Media Lab ConsortiumProcter & Gamble Compan

    Real-Time Inference of Mental States from Facial Expressions and Upper Body Gestures

    No full text
    We present a real-time system for detecting facial action units and inferring emotional states from head and shoulder gestures and facial expressions. The dynamic system uses three levels of inference on progressively longer time scales. Firstly, facial action units and head orientation are identified from 22 feature points and Gabor filters. Secondly, Hidden Markov Models are used to classify sequences of actions into head and shoulder gestures. Finally, a multi level Dynamic Bayesian Network is used to model the unfolding emotional state based on probabilities of different gestures. The most probable state over a given video clip is chosen as the label for that clip. The average F1 score for 12 action units (AUs 1, 2, 4, 6, 7, 10, 12, 15, 17, 18, 25, 26), labelled on a frame by frame basis, was 0.461. The average classification rate for five emotional states (anger, fear, joy, relief, sadness) was 0.440. Sadness had the greatest rate, 0.64, anger the smallest, 0.11.Thales Research and Technology (UK)Bradlow Foundation TrustProcter & Gamble Compan

    Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera

    No full text
    Remote measurement of the blood volume pulse via photoplethysmography (PPG) using digital cameras and ambient light has great potential for healthcare and affective computing. However, traditional RGB cameras have limited frequency resolution. We present results of PPG measurements from a novel five band camera and show that alternate frequency bands, in particular an orange band, allowed physiological measurements much more highly correlated with an FDA approved contact PPG sensor. In a study with participants (n = 10) at rest and under stress, correlations of over 0.92 (p <; 0.01) were obtained for heart rate, breathing rate, and heart rate variability measurements. In addition, the remotely measured heart rate variability spectrograms closely matched those from the contact approach. The best results were obtained using a combination of cyan, green, and orange (CGO) bands; incorporating red and blue channel observations did not improve performance. In short, RGB is not optimal for this problem: CGO is better. Incorporating alternative color channel sensors should not increase the cost of such cameras dramatically

    Biophone: Physiology monitoring from peripheral smartphone motions

    No full text
    The large-scale adoption of smartphones during recent years has created many opportunities to improve health monitoring and care delivery. In this work, we demonstrate that motion sensors available in off-the-shelf smartphones can capture physiological parameters of a person during stationary postures, even while being carried in a bag or a pocket. In particular, we develop methods to extract heart and breathing rates from accelerometer data and compare them with measurements obtained with FDA-cleared sensors. We evaluated their accuracy on 12 people across different still body postures (pre- and post- exercise) and were able to reach mean absolute errors of 1.16 beats per minute (STD: 3) and 0.26 breaths per minute (STD: 0.5) when considering different conditions. Furthermore, we evaluated the same methods during regular phone activities, such as when watching a video or listening to a conversation, yielding increased but still comparable error rates for some conditions.National Science Foundation (U.S.) (NSF CCF-1029585)Samsung (Firm)MIT Media Lab Consortiu

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Acume: A New Visualization Tool for Understanding Facial Expression and Gesture Data

    No full text
    Facial and head actions contain significant affective information. To date, these actions have mostly been studied in isolation because the space of naturalistic combinations is vast. Interactive visualization tools could enable new explorations of dynamically changing combinations of actions as people interact with natural stimuli. This paper describes a new open-source tool that enables navigation of and interaction with dynamic face and gesture data across large groups of people, making it easy to see when multiple facial actions co-occur, and how these patterns compare and cluster across groups of participants. We share two case studies that demonstrate how the tool allows researchers to quickly view an entire corpus of data for single or multiple participants, stimuli and actions. Acume yielded patterns of actions across participants and across stimuli, and helped give insight into how our automated facial analysis methods could be better designed. The results of these case studies are used to demonstrate the efficacy of the tool. The open-source code is designed to directly address the needs of the face and gesture research community, while also being extensible and flexible for accommodating other kinds of behavioral data. Source code, application and documentation are available at http://affect.media.mit.edu/acume.Procter & Gamble Compan

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Remote Detection of Photoplethysmographic Systolic and Diastolic Peaks Using a Digital Camera

    No full text
    We present a new method for measuring photoplethysmogram signals remotely using ambient light and a digital camera that allows for accurate recovery of the waveform morphology (from a distance of 3 m). In particular, we show that the peak-to-peak time between the systolic peak and diastolic peak/inflection can be automatically recovered using the second-order derivative of the remotely measured waveform. We compare measurements from the face with those captured using a contact fingertip sensor and show high agreement in peak and interval timings. Furthermore, we show that results can be significantly improved using orange, green, and cyan color channels compared to the tradition red, green, and blue channel combination. The absolute error in interbeat intervals was 26 ms and the absolute error in mean systolic-diastolic peak-to-peak times was 12 ms. The mean systolic-diastolic peak-to-peak times measured using the contact sensor and the camera were highly correlated, ρ = 0.94 (p <; 0.001). The results were obtained with a camera frame-rate of only 30 Hz. This technology has significant potential for advancing healthcare.MIT Media Member consortiumNihon Denki Kabushiki Kaisha (NEC fellowship
    corecore