1,720,960 research outputs found

    RE-PERG, a new paradigm for glaucoma diagnosis, in myopic eyes

    Full text link
    Purpose: To evaluate reliability of steady-state pattern electroretinogram (ssPERG) phase variability in re-test (procedure called RE-PERG) in the presence of myopia, which is known to affect ssPERG amplitude, in glaucomatous patients (GP), normal controls (NC), and myopic patients (MY).Methods: The procedure was performed on 50 GP, 35 NC, and 19 MY. All subjects were examined with RE-PERG, spectral-domain coherence tomography (SD-OCT), and standard automated perimetry (SAP). Standard deviation of phase (ssPERG SDph) and mean amplitude value (ssPERG Amp) of second harmonic (2ndH) were correlated, by means of one-way ANOVA and Pearson correlation, with mean deviation (MD) and pattern standard deviation (PSD) assessed by SAP and retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness assessed by SD-OCT. Receiving operating characteristics were calculated in cohort populations with and without myopia.Results: GP showed significant differences from the control group for MD, PSD, RNFL, GCC, ssPERG Amp, and ssPERG SDph; GP also showed significant differences from the MY group for all the parameters except for ssPERG Amp, which is reduced in both groups. In GP group, ssPERG Amp showed a specificity of 82.1% (95% confidence interval [CI]I: 66.5-92.5). In MY group, ssPERG Amp was reduced in 58% of the patients. As a consequence of this, in GP and MY groups, considered as a whole, total specificity dropped to 70.69% (95% CI: 57.3-81.9). In the GP group, ssPERG SDph showed a specificity of 84.6% (95% CI: 69.5-91.1). In both GP and MY groups, considered as a whole, ssPERG SDph total specificity increased from 84.6% to 93.1% (95% CI: 83.3-98.1).Conclusion: Intrinsic phase variability of ssPERG is not influenced by myopia, even in the presence of fundus alterations

    RE-PERG, a new procedure for electrophysiologic diagnosis of glaucoma that may improve PERG specificity

    Full text link
    Purpose: A significant variability of the second harmonic (2ndH) phase of steady-state pattern electroretinogram (SS-PERG) in intrasession retest has been recently described in glaucoma patients (GP), which has not been found in healthy subjects. To evaluate the reliability of phase variability in retest (a procedure called RE-PERG or REPERG) in the presence of cataract, which is known to affect standard PERG, we tested this procedure in GP, normal controls (NC), and cataract patients (CP). Methods: The procedure was performed on 50 GP, 35 NC, and 27 CP. All subjects were examined with RE-PERG and SS-PERG and also with spectral domain optical coherence tomography and standard automated perimetry. Standard deviation of phase and amplitude value of 2ndH were correlated by means of one-way analysis of variance and Pearson correlation, with the mean deviation and pattern standard deviation assessed by standard automated perimetry and retinal nerve fiber layer and the ganglion cell complex thickness assessed by spectral domain optical coherence tomography. Receiver operating characteristics were calculated in cohort populations with and without cataract. Results: Standard deviation of phase of 2ndH was significantly higher in GP with respect to NC (P<0.001) and CP (P<0.001), and it correlated with retinal nerve fiber layer (r=−0.5, P<0.001) and ganglion cell complex (r=−0.6, P<0.001) defects in GP. Receiver operating characteristic evaluation showed higher specificity of RE-PERG (86.4%; area under the curve 0.93) with respect to SS-PERG (54.5%; area under the curve 0.68) in CP. Conclusion: RE-PERG may improve the specificity of SS-PERG in clinical practice in the discrimination of GP

    Retrograde Optic Nerve Degeneration in Pituitary Adenoma: A Study with RE-PERG

    Full text link
    PURPOSE: RE-PERG is altered in presence of primary neuronal degeneration of retinal ganglion cells, both in glaucoma and other diseases. A previous study showed that in a model of retrograde degeneration (vascular dementia) RE-PERG was normal. In this study, we enrolled patients with pituitary adenoma (PA) to evaluate RE-PERG findings in another model of retrograde degeneration compared with healthy controls (HC). Based on the outcome of the present and our previous studies with RE-PERG, and reviewing the literature, we discuss the physiopathology of glaucoma. METHODS: Twelve PA patients and 14 age-matched HC were recruited. All participants performed visual field (VF) test, retinal nerve fiber layer (RNFL) and ganglion cells complex (GCC) thickness measurement by means of optical coherence tomography (OCT), visual evoked potentials (VEPs) and RE-PERG, a non-invasive, fast steady-state pattern electroretinogram (SS-PERG) sampled in five consecutive blocks of 130 events. RESULTS: VEPs amplitude was significantly lower in PA with respect to HC (6.8±0.6 vs 7.4±0.6 µV; p=0.045). VEPs latency was higher in PA (123.2±5.8 vs 103.6±4.1 msec; p<0.01). As for VF, mean defect (MD) and pattern standard deviation (PSD) were higher in PA (−6.6±2.6 vs −0.01±1.02 dB; p<0.01 and 8.5±3.1 vs 1.5±0.3; p<0.01, respectively). RNFL thickness was lower in PA (88±8.1 vs 97±9.3 µ; p=0.01). There was no statistically significant difference between PA and HC for RE-PERG. There was a significant correlation among MD, PSD, VEPs amplitude, PERG amplitude and RNFL thickness in the PA group, whereas no correlation was found with SDPh, which remains as normal as in the HC group. CONCLUSION: Our findings confirm that RE-PERG is not altered in retrograde degeneration. Based on the outcome of the present and our previous studies about RE-PERG and glaucoma, we assume that in glaucoma a double mechanism of retinal ganglion cells degeneration, both retrograde and primary, can coexist

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore