1,720,958 research outputs found
Extracorporeal membrane oxygenation for adult respiratory distress syndrome in trauma patients
BACKGROUND: Venovenous extracorporeal membrane oxygenation (vv-ECMO) is an established salvage therapy for severe respiratory failure, and may provide an alternative form of treatment for trauma-induced adult respiratory distress syndrome (ARDS) when conventional treatments have failed. The need for systemic anticoagulation is a relative contraindication for patients with bleeding risks, especially in multitraumatic injury.METHODS: We describe a case series of four trauma patients with ARDS who were managed with ECMO admitted to the neuro critical care unit at Addenbrooke's Hospital, Cambridge (UK), from January 2000 to January 2016. We performed a systematic review of the available literature to investigate the safety and efficacy of vv-ECMO in posttraumatic ARDS, focusing on the use of different anticoagulation strategies and risk of bleeding on patients with multiple injuries.RESULTS: Thirty-one patients were included. A heparin bolus was given in 16 cases. Eleven patients developed complications during treatment with ECMO with three cases of major bleeding. In all documented cases of bleeding a bolus and infusion of heparin was administered, aiming for an activated clotting time (ACT) target longer than 150 seconds. Two patients treated with heparin-free ECMO developed thromboembolic complications. Four patients died, and death was never directly or indirectly related to use of ECMO.CONCLUSION: vv-ECMO can be lifesaving in respiratory failure. Our experience and our literature review suggest that vv-ECMOshould be considered as a rescue treatment for the management of severe hypoxemic respiratory failure secondary to ARDS in trauma patients. For patients with a high risk of bleeding, the use of ECMO with no initial anticoagulation could be considered a valid option. For patients with a moderate risk of bleeding, use of a heparin infusion keeping an ACT target shorter than 150 seconds can be appropriate. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.
The role of noninvasive brain oximetry in adult critically ill patients without primary non-anoxic brain injury
A primary objective in intensive care and perioperative settings is to promote an adequate supply and delivery of oxygen to tissues and organs, particularly to the brain. Cerebral near infrared spectroscopy (NIRS) is a noninvasive, continuous monitoring technique, that can be used to assess cerebral oxygenation. Using NIRS to monitor cerebral oximetry is not new and has been in widespread use in neonates and cardiac surgery for decades. In addition, it has become common to see NIRS being used in adult and pediatric cardiac surgery, acute neurological diseases, neurosurgical procedures, vascular surgery, severe trauma and other acute medical diseases. Furthermore, recent evidence suggests a role for NIRS in the perioperative settings; detecting and preventing episodes of cerebral desaturation aiming to reduce the development of postoperative delirium. NIRS is not without its limitations; these include the risk of extra-cranial contamination, spatial limitations and skin blood flow/volume changes, as well being a measure of localized blood oxygenation underneath the sensor. However, NIRS is a noninvasive technique and can be used in those patients without indications or justification for invasive brain monitoring; non-neurosurgical procedures such as liver transplantation, major orthopedic surgery and critically illness where the brain is at risk. The aim of this manuscript was to discuss the physical principles of NIRS and to report the current evidence regarding its use in critically ill patients without primary non-anoxic brain injury.SCOPUS: re.jinfo:eu-repo/semantics/publishe
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
