51 research outputs found
Design of a monitoring network: from macro to micro design
The knowledge of water levels and discharges in urban drainage and stormwater management (UDSM) systems is of key importance to understand their functioning and processes, to evaluate their performance, and to provide data for modelling. In this chapter, devoted mainly to underground combined and separate sewer pipe systems, various methods and technologies are described and discussed. After an introduction to important aspects to deal with when measuring discharges in sewer systems, the following parts are presented successively: (i) measurement of water level with rulers, and pressure, ultrasonic and radar sensors, (ii) measurement of flow velocity with ultrasonic, Doppler, velocity profiler, free surface, and electromagnetic sensors, (iii) direct measurement of discharge with pre-calibrated devices, physical scale models, computational fluid dynamics modelling and use of pumping stations, and (iv) detection and/or measurement of infiltration into and exfiltration from sewers, with flow or pressure measurements, tracer experiments, distributed temperature sensing and geophysical methods.Sanitary Engineerin
Data validation and data quality assessment
Once data have been recorded, data validation procedures have to be conducted to assess the quality of the data, i.e. give a confidence grade. Furthermore, gaps may occur in time series and, depending on the purposes, these can be given values by application of e.g. interpolation. Since both aspects are strongly correlated, this chapter gives an overview on the main data validation and data curation/imputation methods. Instead of offering exhaustive details on existing methods, this chapter aims at providing concepts for most popular techniques, a discussion of their advantages and disadvantages in the light of different cases of application, and some thoughts on potential impacts of the choices that must be made. Despite involving mathematical methods, data validation remains a largely subjective process: every data user must be aware of those subjectivities.Sanitary Engineerin
Data archiving and meta-data – saving the data for the future use
This chapter covers the main aspects of data archiving, as the last phase of data handling in the process of Urban Drainage Metrology. Data archiving is the process of preparing and storing the data for future use, usually not by the ones who acquired the data. Data archive (also known as data repository) can be defined as storage of selected subset of raw, processed, validated and resampled data, with descriptions and other metadata, linked to simulation results, if there are any. Data archive should be equipped with tools for search and data extraction and also procedures for data management, in order to maintain the database for long period of time. It is recommended, mostly for security reasons, to separate the archive database from working database. This chapter will provide the reader with relevant information about the most important issues related to data archive design, archiving process and data characteristics regarding archiving. Also, the importance of good and comprehensive metadata is underlined throughout the chapter. The management of data archive is evaluated with special focus on predicting future resources needed to keep the archive updated, secure, available, and complied to legal aspects. At the end, the set of recommendations for creating and maintaining data archive in the scope of urban drainage are given.Editors: J.-L. Bertrand-Krajewski and F.H.L.R. Clemens-Meyer and M. Lepot;
Data files and programs at: data files at https://doi.org/10.2166/9781789060102 ;
Book available at: https://iwaponline.com/ebooks/book/835/Metrology-in-Urban-Drainage-and-Stormwate
Data collection in urban drainage and stormwater management systems – case studies
Data collection in urban drainage systems comes with many challenges. However, many examples already exist, containing numerous useful lessons learned. This chapter therefore contains several urban drainage and stormwater management metrology case studies, selected to cover a wide range of scopes, scales, objectives, climates, data validation methods, and data storage approaches. The case studies are initiated by academics as well as by institutions from the water industry.Sanitary Engineerin
General introduction and book layout
This introductory chapter indicates why well-defined, high-standard, and reliable monitoring is a key aspect in the necessary evolution of urban drainage and stormwater management and why it should become routine practice. It provides a framework, guidelines, and recommendations to define monitoring objectives and means. It also presents the structure and the chapters of the rest of the book.Sanitary Engineerin
Prikaz knjige ``Metrology in Urban Drainage and Stormwater Management: Plug and Pray'', IWA
Prikaz radne verzije knjige: Metrology in Urban Drainage and Stormwater Management: Plug and Pray. Editori: Jean-Luc BERTRAND-KRAJEWSKI, François Clemens and Mathieu Lepot. Izdavač: IWA PublishingKonfrencija Jahorina virtual 2021. Link na stranu organizatora sa svim prezentacijama: https://utvsi.com/jahorina-virtual-2021/ . Prezentacija: https://utvsi.com/wp-content/uploads/2021/05/PrikazKnjige-MetrologyInUD-Dusan-Prodanovic-min.pdf . Knjiga je dostupna na adresi: https://iwaponline.com/ebooks/book/835/Metrology-in-Urban-Drainage-and-Stormwate
Mesurage en continu des flux polluants en MES et DCO en réseau d'assainissement
Flowmeters are well known technologies and highly prevalent but not free of errors, the causes can be quite varied. These sensors installed in sewer systems can’t be in situ calibrate. A method of in situ verification of flow meters, used for pseudo-calibrations, is presented. Indeed, the injection of a tracer in a flow allows to calculate the flow and its uncertainty in a manner independent of probes in place. This methodology, in seven steps, provides results comparable to those provided by methods considered standards (tracer salts and electromagnetic flowmeter). The first applications in combined sewers were conducted for verification of flowmeters (along a main pipe of Greater Lyon) and for calibrations curves (the Syndicat Intercommunal Grand Sanitation Project). For qualitative measures of influents, many previous studies have shown good correlations between pollutant concentrations and the signals provided by turbidimeters and UV/visible spectrometers. A pilot and experimental samples taken during campaigns on the pretreated influent of the waste water treatment plant of Fontaines-sur-Saône, a bench was built to meet the following objectives: i) design and test a site measuring of a new generation, ii) seek regression models among different sensors (single and dual length(s)-wavelength(s) turbidimeters, conductivity meter, pH meter, UV/visible spectrometer, microwave sensors) and pollutant concentrations for samples of dry weather, wet weather and all, iii) characterize the performance of these models and iv) test the robustness of the proposed methods under atypical conditions but succeptibles to be encountered in sewers. The results confirm the good correlations between few parameters (turbidity, conductivity and UV/Vis fingerprint) and pollutant concentrations. No sensor is the most efficient for all pollutants. The majority of sensors deliver similar estimates to uncertainties but these estimates are little or no redundant with laboratory analysis. The design of the bench (and changes in wastewater matrices) and / or experimental conditions during the tests of robustness may be involved.Les débitmètres sont des technologies connues et fortement répandues mais pas exemptes d’erreurs, dont les causes peuvent être assez variées. Ces capteurs installés dans les systèmes d’assainissement ne sont de plus pas rigoureusement étalonnables in situ. Une méthode de vérification in situ des débitmètres, utilisable pour des pseudos étalonnages, est présentée. En effet, l’injection ponctuelle d’un traceur dans un écoulement permet de calculer le débit et son incertitude d’une manière indépendante des sondes en place. Cette méthodologie, en sept étapes, offre des résultats comparables à ceux fournis par des méthodes considérées comme des références (traçages aux sels et débitmètre électromagnétique). Des premiers essais en réseaux unitaires ont été réalisés pour la vérification de débitmètres (le long d’un collecteur du Grand Lyon) et pour le calage de courbes de tarages (sur le Syndicat Intercommunal d’Assainissement Grand Projet). Pour les mesures qualitatives des effluents, de nombreuses études antérieures ont montrées de bonnes corrélations entre les concentrations en polluants et les signaux fournis par des turbidimètres et des spectromètres UV/visible. Un pilote expérimental et des campagnes d’échantillonnages sur des effluents prétraités de la station d’épuration de Fontaines sur Saône ont été mis en place pour répondre aux objectifs suivants : i) concevoir et tester un site de mesure de nouvelle génération, ii) chercher des modèles de régressions entres différents capteurs (turbidimètres mono et bi-longueur(s) d’onde(s), conductimètre, pHmètre, spectromètre UV/visible, capteurs à micro-ondes) et les concentrations en polluants pour les échantillons de temps sec, de temps de pluie et la totalité, iii) caractériser la performance de ces modèles et iv) tester la robustesse des méthodes proposées sous des conditions atypiques mais susceptibles d’être rencontrées en réseau d’assainissement. Les résultats confirment les bonnes corrélations entre certains paramètres (turbidité, conductivité et spectre UV/visible) et les concentrations en polluants. Aucun capteur n’est le plus performant pour l’ensemble des polluants. La majorité des capteurs délivrent des estimations comparables aux incertitudes près mais ces estimations sont peu voire pas redondantes aux analyses effectuées sur les échantillons. La conception du banc (et les variations des matrices des eaux usées) et/ou les conditions expérimentales lors des tests de robustesse sont peut être en cause
On-line monitoring of polluant fluxes (TSS and COD) in sewers
Les débitmètres sont des technologies connues et fortement répandues mais pas exemptes d’erreurs, dont les causes peuvent être assez variées. Ces capteurs installés dans les systèmes d’assainissement ne sont de plus pas rigoureusement étalonnables in situ. Une méthode de vérification in situ des débitmètres, utilisable pour des pseudos étalonnages, est présentée. En effet, l’injection ponctuelle d’un traceur dans un écoulement permet de calculer le débit et son incertitude d’une manière indépendante des sondes en place. Cette méthodologie, en sept étapes, offre des résultats comparables à ceux fournis par des méthodes considérées comme des références (traçages aux sels et débitmètre électromagnétique). Des premiers essais en réseaux unitaires ont été réalisés pour la vérification de débitmètres (le long d’un collecteur du Grand Lyon) et pour le calage de courbes de tarages (sur le Syndicat Intercommunal d’Assainissement Grand Projet). Pour les mesures qualitatives des effluents, de nombreuses études antérieures ont montrées de bonnes corrélations entre les concentrations en polluants et les signaux fournis par des turbidimètres et des spectromètres UV/visible. Un pilote expérimental et des campagnes d’échantillonnages sur des effluents prétraités de la station d’épuration de Fontaines sur Saône ont été mis en place pour répondre aux objectifs suivants : i) concevoir et tester un site de mesure de nouvelle génération, ii) chercher des modèles de régressions entres différents capteurs (turbidimètres mono et bi-longueur(s) d’onde(s), conductimètre, pHmètre, spectromètre UV/visible, capteurs à micro-ondes) et les concentrations en polluants pour les échantillons de temps sec, de temps de pluie et la totalité, iii) caractériser la performance de ces modèles et iv) tester la robustesse des méthodes proposées sous des conditions atypiques mais susceptibles d’être rencontrées en réseau d’assainissement. Les résultats confirment les bonnes corrélations entre certains paramètres (turbidité, conductivité et spectre UV/visible) et les concentrations en polluants. Aucun capteur n’est le plus performant pour l’ensemble des polluants. La majorité des capteurs délivrent des estimations comparables aux incertitudes près mais ces estimations sont peu voire pas redondantes aux analyses effectuées sur les échantillons. La conception du banc (et les variations des matrices des eaux usées) et/ou les conditions expérimentales lors des tests de robustesse sont peut être en cause.Flowmeters are well known technologies and highly prevalent but not free of errors, the causes can be quite varied. These sensors installed in sewer systems can’t be in situ calibrate. A method of in situ verification of flow meters, used for pseudo-calibrations, is presented. Indeed, the injection of a tracer in a flow allows to calculate the flow and its uncertainty in a manner independent of probes in place. This methodology, in seven steps, provides results comparable to those provided by methods considered standards (tracer salts and electromagnetic flowmeter). The first applications in combined sewers were conducted for verification of flowmeters (along a main pipe of Greater Lyon) and for calibrations curves (the Syndicat Intercommunal Grand Sanitation Project). For qualitative measures of influents, many previous studies have shown good correlations between pollutant concentrations and the signals provided by turbidimeters and UV/visible spectrometers. A pilot and experimental samples taken during campaigns on the pretreated influent of the waste water treatment plant of Fontaines-sur-Saône, a bench was built to meet the following objectives: i) design and test a site measuring of a new generation, ii) seek regression models among different sensors (single and dual length(s)-wavelength(s) turbidimeters, conductivity meter, pH meter, UV/visible spectrometer, microwave sensors) and pollutant concentrations for samples of dry weather, wet weather and all, iii) characterize the performance of these models and iv) test the robustness of the proposed methods under atypical conditions but succeptibles to be encountered in sewers. The results confirm the good correlations between few parameters (turbidity, conductivity and UV/Vis fingerprint) and pollutant concentrations. No sensor is the most efficient for all pollutants. The majority of sensors deliver similar estimates to uncertainties but these estimates are little or no redundant with laboratory analysis. The design of the bench (and changes in wastewater matrices) and / or experimental conditions during the tests of robustness may be involved
Mesurage en continu des flux polluants en MES et DCO en réseau d'assainissement
Flowmeters are well known technologies and highly prevalent but not free of errors, the causes can be quite varied. These sensors installed in sewer systems can’t be in situ calibrate. A method of in situ verification of flow meters, used for pseudo-calibrations, is presented. Indeed, the injection of a tracer in a flow allows to calculate the flow and its uncertainty in a manner independent of probes in place. This methodology, in seven steps, provides results comparable to those provided by methods considered standards (tracer salts and electromagnetic flowmeter). The first applications in combined sewers were conducted for verification of flowmeters (along a main pipe of Greater Lyon) and for calibrations curves (the Syndicat Intercommunal Grand Sanitation Project). For qualitative measures of influents, many previous studies have shown good correlations between pollutant concentrations and the signals provided by turbidimeters and UV/visible spectrometers. A pilot and experimental samples taken during campaigns on the pretreated influent of the waste water treatment plant of Fontaines-sur-Saône, a bench was built to meet the following objectives: i) design and test a site measuring of a new generation, ii) seek regression models among different sensors (single and dual length(s)-wavelength(s) turbidimeters, conductivity meter, pH meter, UV/visible spectrometer, microwave sensors) and pollutant concentrations for samples of dry weather, wet weather and all, iii) characterize the performance of these models and iv) test the robustness of the proposed methods under atypical conditions but succeptibles to be encountered in sewers. The results confirm the good correlations between few parameters (turbidity, conductivity and UV/Vis fingerprint) and pollutant concentrations. No sensor is the most efficient for all pollutants. The majority of sensors deliver similar estimates to uncertainties but these estimates are little or no redundant with laboratory analysis. The design of the bench (and changes in wastewater matrices) and / or experimental conditions during the tests of robustness may be involved.Les débitmètres sont des technologies connues et fortement répandues mais pas exemptes d’erreurs, dont les causes peuvent être assez variées. Ces capteurs installés dans les systèmes d’assainissement ne sont de plus pas rigoureusement étalonnables in situ. Une méthode de vérification in situ des débitmètres, utilisable pour des pseudos étalonnages, est présentée. En effet, l’injection ponctuelle d’un traceur dans un écoulement permet de calculer le débit et son incertitude d’une manière indépendante des sondes en place. Cette méthodologie, en sept étapes, offre des résultats comparables à ceux fournis par des méthodes considérées comme des références (traçages aux sels et débitmètre électromagnétique). Des premiers essais en réseaux unitaires ont été réalisés pour la vérification de débitmètres (le long d’un collecteur du Grand Lyon) et pour le calage de courbes de tarages (sur le Syndicat Intercommunal d’Assainissement Grand Projet). Pour les mesures qualitatives des effluents, de nombreuses études antérieures ont montrées de bonnes corrélations entre les concentrations en polluants et les signaux fournis par des turbidimètres et des spectromètres UV/visible. Un pilote expérimental et des campagnes d’échantillonnages sur des effluents prétraités de la station d’épuration de Fontaines sur Saône ont été mis en place pour répondre aux objectifs suivants : i) concevoir et tester un site de mesure de nouvelle génération, ii) chercher des modèles de régressions entres différents capteurs (turbidimètres mono et bi-longueur(s) d’onde(s), conductimètre, pHmètre, spectromètre UV/visible, capteurs à micro-ondes) et les concentrations en polluants pour les échantillons de temps sec, de temps de pluie et la totalité, iii) caractériser la performance de ces modèles et iv) tester la robustesse des méthodes proposées sous des conditions atypiques mais susceptibles d’être rencontrées en réseau d’assainissement. Les résultats confirment les bonnes corrélations entre certains paramètres (turbidité, conductivité et spectre UV/visible) et les concentrations en polluants. Aucun capteur n’est le plus performant pour l’ensemble des polluants. La majorité des capteurs délivrent des estimations comparables aux incertitudes près mais ces estimations sont peu voire pas redondantes aux analyses effectuées sur les échantillons. La conception du banc (et les variations des matrices des eaux usées) et/ou les conditions expérimentales lors des tests de robustesse sont peut être en cause
Mesurage en continu des flux polluants en MES et DCO en réseau d'assainissement
Flowmeters are well known technologies and highly prevalent but not free of errors, the causes can be quite varied. These sensors installed in sewer systems can’t be in situ calibrate. A method of in situ verification of flow meters, used for pseudo-calibrations, is presented. Indeed, the injection of a tracer in a flow allows to calculate the flow and its uncertainty in a manner independent of probes in place. This methodology, in seven steps, provides results comparable to those provided by methods considered standards (tracer salts and electromagnetic flowmeter). The first applications in combined sewers were conducted for verification of flowmeters (along a main pipe of Greater Lyon) and for calibrations curves (the Syndicat Intercommunal Grand Sanitation Project). For qualitative measures of influents, many previous studies have shown good correlations between pollutant concentrations and the signals provided by turbidimeters and UV/visible spectrometers. A pilot and experimental samples taken during campaigns on the pretreated influent of the waste water treatment plant of Fontaines-sur-Saône, a bench was built to meet the following objectives: i) design and test a site measuring of a new generation, ii) seek regression models among different sensors (single and dual length(s)-wavelength(s) turbidimeters, conductivity meter, pH meter, UV/visible spectrometer, microwave sensors) and pollutant concentrations for samples of dry weather, wet weather and all, iii) characterize the performance of these models and iv) test the robustness of the proposed methods under atypical conditions but succeptibles to be encountered in sewers. The results confirm the good correlations between few parameters (turbidity, conductivity and UV/Vis fingerprint) and pollutant concentrations. No sensor is the most efficient for all pollutants. The majority of sensors deliver similar estimates to uncertainties but these estimates are little or no redundant with laboratory analysis. The design of the bench (and changes in wastewater matrices) and / or experimental conditions during the tests of robustness may be involved.Les débitmètres sont des technologies connues et fortement répandues mais pas exemptes d’erreurs, dont les causes peuvent être assez variées. Ces capteurs installés dans les systèmes d’assainissement ne sont de plus pas rigoureusement étalonnables in situ. Une méthode de vérification in situ des débitmètres, utilisable pour des pseudos étalonnages, est présentée. En effet, l’injection ponctuelle d’un traceur dans un écoulement permet de calculer le débit et son incertitude d’une manière indépendante des sondes en place. Cette méthodologie, en sept étapes, offre des résultats comparables à ceux fournis par des méthodes considérées comme des références (traçages aux sels et débitmètre électromagnétique). Des premiers essais en réseaux unitaires ont été réalisés pour la vérification de débitmètres (le long d’un collecteur du Grand Lyon) et pour le calage de courbes de tarages (sur le Syndicat Intercommunal d’Assainissement Grand Projet). Pour les mesures qualitatives des effluents, de nombreuses études antérieures ont montrées de bonnes corrélations entre les concentrations en polluants et les signaux fournis par des turbidimètres et des spectromètres UV/visible. Un pilote expérimental et des campagnes d’échantillonnages sur des effluents prétraités de la station d’épuration de Fontaines sur Saône ont été mis en place pour répondre aux objectifs suivants : i) concevoir et tester un site de mesure de nouvelle génération, ii) chercher des modèles de régressions entres différents capteurs (turbidimètres mono et bi-longueur(s) d’onde(s), conductimètre, pHmètre, spectromètre UV/visible, capteurs à micro-ondes) et les concentrations en polluants pour les échantillons de temps sec, de temps de pluie et la totalité, iii) caractériser la performance de ces modèles et iv) tester la robustesse des méthodes proposées sous des conditions atypiques mais susceptibles d’être rencontrées en réseau d’assainissement. Les résultats confirment les bonnes corrélations entre certains paramètres (turbidité, conductivité et spectre UV/visible) et les concentrations en polluants. Aucun capteur n’est le plus performant pour l’ensemble des polluants. La majorité des capteurs délivrent des estimations comparables aux incertitudes près mais ces estimations sont peu voire pas redondantes aux analyses effectuées sur les échantillons. La conception du banc (et les variations des matrices des eaux usées) et/ou les conditions expérimentales lors des tests de robustesse sont peut être en cause
- …