1,720,955 research outputs found
A study to determine the use of cross cylinder in conjunction with the cross grid at distance as an alternative method for the duochrome technique amongst University of Limpopo optometry students
Thesis (M. Optometry) -- University of Limpopo, 2019BACKGROUND The measurement of the refractive end point plays a major role in the assessment of the refractive status of the patient. Currently, there are very few techniques if not one that can measure the refractive end point of the patient. The current method which is the duochrome technique is based on chromatic aberration. Until now there is no test for refractive end point that is not based on chromatic aberration. Therefore, it was against this background that the current study was undertaken to investigate an alternative for the duochrome technique to measure the refractive end point.
AIM OF THE STUDY The aim of this study was to establish the use of cross grid in conjunction with Jackson crossed cylinders at distance as a monocular refractive end point technique.
METHODOLOGY A cross-sectional analytic and descriptive study design was used. Sixty-four subjects (31 males and 33 females) were included in this study. Their ages ranged from 18 to 37 years with a mean of 20.75 years (SD = ± 2.67 years). The participants were University of Limpopo Optometry students. Ethical approval to perform this study was obtained from the Turfloop Research Ethics Committee (TREC) of University of Limpopo. All participants were made aware of the purpose of the study, and signed consent was obtained from each participant. All investigations and measurements adhered to the tenets or principles, belief and requirements of the Declaration of Helsinki. Optometric procedures performed included visual acuity, subjective measurement of refractive error, monocular refractive end point using duochrome technique and monocular refractive end point measurement using gross grid in conjunction with the cross grid. Data analysis was done using the Statistical Package for Social Sciences (SPSS) Version 23. Paired sample t-test was performed on all the procedures.
RESULTS The uncorrected distance VA for the right eyes (OD) ranged from -0.30 LogMAR to 1.00 LogMAR with a mean of -0.25 LogMAR (SD = ±0.32). The nearest equivalent spherical powers (NSE = sphere +0.5 cylinder) for the right eye ranged from -4.25 to +4.25D (mean = -0.13, SD= ±1.09D) and from -4.50D to +1.00D (mean = +0.07 ±0.94D) for the left eye. After the removal of outliers, the refractive end point measurements with the duochrome technique for the right eyes ranged from -4.50D to 3.50D with a mean of -0.269, SD (±1.037) in bright illumination and from -4.50D to 4.50D with a mean of -1.914 (±1.101) in dim illumination. Subsequently, the NSE with the crossed cylinder in conjunction with the cross grid technique for the right eyes in bright illumination ranged from -4.75D to 4.75D with a mean of -0.481, SD (±1.037) and from -4.25D to 0.50D with a mean of -0.427 (±0.860) in dim illumination.
Sample Pearson correlation coefficients for end point with duochrome and crossed cylinder found that the highest correlation is between the duochrome in bright and cross grid in dim illumination (r = 0.701, p < 0.05), while duochrome in dim and cross grid in bright illumination had the lowest correlation (r = 0.659). The Bland–Altman plots showed that there was a good agreement between the duochrome methods and between the crossed cylinder method methods.
CONCLUSION the refractive end point measurements obtained from duochrome and cross grid are well correlated and comparable, suggesting that they could be used interchangeably in most clinical settings. However, caution is needed when using measurements obtained by cross grid method in dim illumination
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
The effect of prematurity on visual perceptual skills amongst School-age children in grade 4-6 at Pulamadibogo School in Mankweng, Limpopo Province
Thesis (MPH.) -- University of Limpopo, 2018Children born preterm and low birth weight may have long-term negative
consequences for visual function, compared with children born at full term. Visual
memory (sensory), perceptual skills and learning are of fundamental importance for
a range of functions and everyday activities, such as normal classroom learning,
school performance and social interactions and may contribute to academic
difficulties.The purpose of this study was to investigate the effect of gestational age and birth weight on visual perceptual skills.The study was approved by the University of Limpopo, Turfloop Research Ethics Committee. The Department of Education, Limpopo Province granted permission to conduct the study. Written informed consent was obtained from parents of the children and the study adhered to the tenets of the Helsinki Declaration
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
