1,720,959 research outputs found
Photoacoustic signal enhancement using a novel adaptive filtering algorithm
Photoacoustic (PA) signal experiences excessive background noise when generated using cost-effective, low-energy laser diodes. A denoising technique is essential in this case. Averaging is a common approach to increase the Signal-to-Noise Ratio (SNR) of PA signals. This technique requires numbers of data acquisition in hundreds and thousands and hence, demands more hardware and time consuming at the same time. Here, an adaptive method based on Adaptive Line Enhancers (ALE) algorithm to improve the SNR of PA signals has been presented. Our results validate the feasibility of the usage of an adaptive method and also indicate excellent improvement in terms of increasing the SNR of the PA signals. Additionally, this proposed algorithm requires way less number of acquisitions as compared to the conventional averaging techniques that leads to faster PA image processing
Photoacoustic Signal Enhancement: Towards Utilization of Low Energy Laser Diodes in Real-Time Photoacoustic Imaging
In practice, photoacoustic (PA) waves generated with cost-effective and low-energy laser diodes, are weak and almost buried in noise. Reconstruction of an artifact-free PA image from noisy measurements requires an effective denoising technique. Averaging is widely used to increase the signal-to-noise ratio (SNR) of PA signals; however, it is time consuming and in the case of very low SNR signals, hundreds to thousands of data acquisition epochs are needed. In this study, we explored the feasibility of using an adaptive and time-efficient filtering method to improve the SNR of PA signals. Our results show that the proposed method increases the SNR of PA signals more efficiently and with much fewer acquisitions, compared to common averaging techniques. Consequently, PA imaging is conducted considerably faster
A BCB Diaphragm Based Adhesive Wafer Bonded CMUT Probe for Biomedical Application
This dissertation presents the design methodology, fabrication procedure, and key experimental characterization results of a linear array of capacitive micromachined ultrasonic transducers (CMUT) for possible ophthalmic anterior segment imaging application. The design methodology involves analytical, 3-D electromechanical finite element analysis, and Verasonics Vantage 128 ultrasonic research platform based diagnostic imaging simulations to develop a technique that minimizes electrical charging and center frequency drift while improving the transduction efficiency. In the design, Bisbenzocyclobutene (BCB), a low K polymer from Dow Chemical Company, has been innovatively used for the first time to fabricate the structural layer of the CMUT diaphragm, realize the interelectrode dielectric spacer, and to act as a low temperature adhesive bonding agent. Additionally, the top CMUT electrode has been placed at the bottom of the diaphragm to affect higher capacitance change that increases sensitivity and provides additional decoupling of the electrical charging effects. Several arrays with element count ranging from 8 to 128 elements and a center frequency range of 5 MHz to 40 MHz have been designed and fabricated. Due to an unforeseen adhesion issue during wirebonding, a 32 channel 40 MHz CMUT array has been packaged manually to validate the fabrication process and CMUT operation. Extensive SEM inspections of the CMUT cross-sections show good agreement with the design specifications. Static and dynamic measurements using a Polytec laser Doppler vibrometer, impedance measurement using an Agilent vector network analyzer, and LCR measurement results are in excellent agreement with analytical and FEA analysis using IntelliSuite. The frequency analysis exhibits high electromechanical coupling coefficient of 0.66 at a low bias voltage of 20 V and high uniformity. A successful measurement of the lower drift of the center frequency 0.32% and higher coupling coefficient verifies the hypothesis that the excellent electrical, structural, and processing characteristics of BCB is a viable option to mitigate the dielectric charging and improve the transduction efficiency of CMUTs
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Technical considerations in the Verasonics research ultrasound platform for developing a photoacoustic imaging system
Photoacoustic imaging (PAI) is an emerging functional and molecular imaging technology that has attracted much attention in the past decade. Recently, many researchers have used the vantage system from Verasonics for simultaneous ultrasound (US) and photoacoustic (PA) imaging. This was the motivation to write on the details of US/PA imaging system implementation and characterization using Verasonics platform. We have discussed the experimental considerations for linear array based PAI due to its popularity, simple setup, and high potential for clinical translatability. Specifically, we describe the strategies of US/PA imaging system setup, signal generation, amplification, data processing and study the system performance.ImPhys/Medical Imagin
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
