1,720,960 research outputs found

    Custom-made, root-analogue direct laser metal forming implant: a case report.

    No full text
    In the last few years, the application of digital technology in dentistry has become widespread with the introduction of cone beam computed tomography (CBCT) scan technology, and considerable progress has been made in the development of computer-aided design/ computer-aided manufacturing (CAD/CAM) techniques, including direct laser metal forming (DLMF). DLMF is a technology which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. At present, the combined use of CBCT 3D data and CAD/CAM technology makes it possible to manufacture custom-made, root-analogue implants (RAI) with sufficient precision. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CBCT images of a non-restorable right maxillary first premolar were acquired and transformed into a 3D model. From this model, a custom-made, root-analogue DLMF implant was fabricated. Immediately after tooth extraction, the RAI with a pre-operatively designed abutment was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the RAI showed a good functional and aesthetic integration. The introduction of DLMF technology signals the start of a new revolutionary era for implant dentistry as its immense potential for producing highly complex macro- and microstructures is receiving vast interest in different medical fields

    Custom-made laser sintered implant placed in atrophic alveolar ridge: A case report

    No full text
    OBJECTIVES. Modern computerized tomography (CT) acquisition and three dimensional image conversion, combined with the new Direct Laser Metal Forming (DLMF) process, allow the fabrication of custom-made, anatomically-shaped implants. This report demonstrates the successful clinical use of a custom-made, anatomically-shaped DLMF, placed in an extremely atrophic mandibular ridge, characterised by bucco-lingual thickness ATERIALS AND METHODS. CT images of the residual atrophic mandibular ridge were required and modified with specific software into a 3D model. From this model, a custom-made, anatomically-shaped one-piece dental implant was fabricated, with the DLMF technique. The implant RESULTS. After 30 months of functional loading, the implant was well integrated from the functional and aesthetic point of view. CONCLUSIONS. The possibility to fabricate custom-made implants opens new interesting horizons in the sental field

    Vertical ridge augmentation of the atrophic posterior mandible with custom-made, computer-aided design/computer-aided manufacturing porous hydroxyapatite scaffolds.

    No full text
    The present study describes a new protocol for the manufacturing of custom-made hydroxyapatite scaffolds using computer-aided design/computer-aided manufacturing (CAD/CAM), to augment posterior mandibular bone and minimize surgery when severe atrophy is present. Computed tomographic images of an atrophic posterior mandible were acquired and modified into a 3-dimensional (3D) reconstruction model. This model was transferred as a stereolithographic file to a CAD program, where virtual 3D reconstructions of the alveolar ridge were performed, drawing 2 anatomically shaped, custom-made scaffolds. Computer-aided-manufacturing software generated a set of tool-paths for manufacture on a computer-numerical-control milling machine into the exact shape of the 3D projects. Clinically sized, anatomically shaped scaffolds were generated from commercially available porous hydroxyapatite blocks. The custom-made scaffolds well matched the shape of the bone defects and could be easily implanted during surgery. This matching of the shape helped to reduce the time for the operation and contributed to the good healing of the defects. At the 6-month recall, a newly formed and well-integrated bone was observed, completely filling the mandibular posterior defects, and implants were placed, with good primary stability. At the 1-year follow-up examination, the implant-supported restorations showed a good functional and esthetic integration. Although this is an interim report, this study demonstrates that anatomically shaped custom-made scaffolds can be fabricated by combining computed tomographic scans and CAD/CAM techniques. Further studies are needed to confirm these results

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore