169,868 research outputs found
Tripeptide KdPT ameliorates intestinal inflammation in patients with mild to moderate active ulcerative colitis
Do We Need Activity Scores or Simply Clear Criteria for Intestinal Ultrasound in Ulcerative Colitis?
Ultrasonography in inflammatory bowel disease ??? So far we are?
Intestinal ultrasound (IUS) is a non-invasive and accurate tool to assess inflammatory bowel disease. The ECCO-ESGAR guideline recommends the use of IUS for the assessment of disease activity and complications in Crohn's disease (CD). In addition, an increasing body of evidence suggests the use of IUS as alternative to colonoscopy in monitoring CD and in assessing disease activity of ulcerative colitis. Early responsiveness of IUS findings by the first weeks of treatment and the advantage to perform the procedure in real time may dramatically change frequency of the assessment of treatment response in the future and speed up the clinical decision-making process. Development of validated and reproducible sonographic scores to measure disease activity and therapeutic response and spread of knowledge of IUS remain relevant issues for the future in which current researchers and the International Bowel Ultrasound (IBUS) Group are actively engaged
Stellungnahme der Ernährungskommission der Deutschen Gesellschaft für Kinder- und Jugendmedizin zur Vermarktung von Beikostprodukten zur Flaschenfütterung
Böhles HJ, Fusch C, Genzel-Boroviczény O, Henker J, Koletzko B , Kersting M, Lentze MJ, Maaser RG, Mihatsch W, Przyrembel H, Wabitsch
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
The failure of gastroenterologists to apply intestinal ultrasound in inflammatory bowel disease in the Asia-Pacific : a need for action
Intestinal ultrasound (IUS) is a cheap, non-invasive, risk-free procedure, which is significantly underutilized in the diagnosis and management of patients with inflammatory bowel disease (IBD) in the Asia-Pacific region. More cost-effective methods of monitoring disease activity are required in light of the increasing global burden of IBD (especially in Asia), the advent of personalized medicine and the rising cost of healthcare. IUS is a prime example of a technique that meets these needs. Its common clinical applications include assessing the activity and complications of IBD. In continental Europe, countries such as Germany and Italy use this imaging tool as the standard of care and have integrated it into management protocols. There are formal training programs in these countries to train gastroenterologists in IUS and it is used in an outpatient setting during patient consultations. Barriers to its use in the Asia-Pacific region include a lack of experience and research data, and there are few established centers with active training programs. These concerns can be addressed by investing more in IUS service provision, and by increasing allocation of resources towards local research and training. Increased uptake of IUS will ultimately benefit patients with IBD
Mitomycin C in highly myopic eyes - Author reply
Ophthalmology. 2005 Feb;112(2):208-18; discussion 219.
Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes.
Gambato C, Ghirlando A, Moretto E, Busato F, Midena E.
SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy.
Abstract
PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes.
DESIGN: Prospective, double-masked, randomized clinical trial.
PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia.
METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months).
MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH.
RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively).
CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK.
Comment in
Ophthalmology. 2006 Feb;113(2):357; author reply 357-8
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
A Multi-Language Comparison of Influences on Author Verification using Character N-Grams
We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc
A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C
Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (> 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
- …
