1,720,959 research outputs found

    Root Injury During Interradicular Insertion is the most Common Complication Associated with Orthodontic Miniscrews

    No full text
    Article Title and Bibliographic Information: Complications reported with the use of orthodontic miniscrews: A systematic review. Giudice AL, Rustico L, Longo M, Oteri G, Papadopoulos MA, Nucera R. Korean J Orthod 2021 May 25;51(3):199–216. doi: 10.4041/kjod.2021.51.3.199. PMID: 33984227. Source of Funding: There is no information about funding. Type of Study/Design: Systematic review

    Orthodontics: Bracket Materials, Adhesives Systems, and Their Bond Strength

    Get PDF
    Adhesive interfaces influence greatly clinical success of modern dentistry. Durability of the interface can be determined by using several in vitro testing methods. Shear bond strength tests are widely used in dentistry and they are well suitable for testing orthodontic materials bonded to teeth. The first study that analyzed shear bond strength of orthodontic appliances appeared in international literature in the late 1970s [1]. Nowadays, more than one thousand reports have been conducted in order to analyze various factors influencing shear bond strength of orthodontic brackets. Precise interpretation of the shear bond strength test results should, however, take into account other types of stress which are occurring at the interface during testing. Previous studies that evaluated bond strength analyzed different variables related to adhesive system (composite or resin-modified glass ionomer), bonding surface (enamel, ceramic, or metal), antibacterial agents (added to adhesive system), bracket material (steel, ceramic, or plastic), bracket type (conventional, self-ligating, or lingual), attachment base (with various mesh sizes and shapes), brace mesh or surface pretreatment (such as sandblasting) [2], bracket placement force, enamel conditioning (with etchants or lasers), enamel pretreatment (with protecting or bleaching agents), and enamel contaminants (such as blood or saliva). The effect of any of these factors may differ when rebonding orthodontic brackets [2–10]. Moreover, bonding studies have been applied to test not only orthodontic brackets but also other materials bonded to tooth structure during active or passive orthodontic treatment (such as customized CAD CAM bases, disinclusion buttons, and fiber reinforced composites bars and nets) [11]. During over 35 years of orthodontic bonding studies, a standardized technique has been reached, but many differences in methods among different studies still remain [12]. Due to increased ethical requirements, the human teeth used are usually wisdom teeth or first premolars (extracted for orthodontic reasons). Bovine teeth are collected in slaughterhouses in deciduous or permanent dentition. Tooth selection includes intact buccal enamel and no cracks due to extraction procedure. After extraction, teeth are stored in thymol, water, or artificial saliva, whereas formalin and alcohol are no more used in order to avoid adverse effects on bond strength measurement. Brackets or jigs are bonded to teeth with an adhesive system and subsequently, or after artificial ageing specimens, are placed in a testing machine with the adhesion surface parallel to shearing force. Predominantly, a shear force is applied with a steel tip with standardized crosshead speed until adhesive failure. Debonding force is recorded in newtons and then often converted into megapascals, which is the unit of stress at the interface. Special attention needs to be paid to ensure the geometry of the bonding site of the bracket allows calculation of stress. In the case of complex form of the bonding site, it is correct to report the bonding properties as debonding load. Moreover, enamel and appliance surfaces are analyzed under optic magnification and an Adhesive Remnant Index (ARI) is assigned to give information of the location of the adhesive failure [13]. ARI score is calculated evaluating the amount of adhesive left on tooth and appliance surfaces after debonding. ARI scale usually ranges from 0 to 3 (0: no resin remaining on tooth; 1: less than 50% resin remaining on tooth; 2: more than 50% resin remaining on tooth; 3: 100% resin remaining on tooth). As it is a standard procedure in biomedical research, statistical analyses are performed with a high enough number of test specimens (i.e., teeth). Descriptive statistics (mean, standard deviation, minimum, median, and maximum values) are calculated for the groups which are compared. The normality of the data can be calculated (e.g., using the Kolmogorov-Smirnov test). Parametric (e.g., ANOVA) or nonparametric (e.g., Kruskal-Wallis) tests are then applied and parametric (e.g., Tukey) or nonparametric (e.g., Mann–Whitney) post hoc tests are used to show differences among various groups. On the other hand, for ARI scores a Chi Squared test is often applied. Significance for all statistical tests is almost always predetermined at P < 0.05. In the literature, there are not clear guidelines about shear force limits, but in fact a good orthodontic biomaterial should allow good adhesion in order to sustain masticatory forces (with a minimum bond strength of 5–10 MPa) [14]. On the other hand, adhesion forces should not be too strong in order to avoid enamel loss after debonding (40–50 MPa) [15]. Therefore, the ideal orthodontic biomaterial should have bonding forces included in the interval of 5–50 MPa, even if these limits are mostly theoretical. When considering ARI index, even if methods of measurement could influence score assignment results [16], ARI score is nowadays widely used in bonding studies to assess and discuss adhesive left on tooth surface after debonding. Generally, a score of “0” is often related to lower shear bond strength values and is often related to contaminants over enamel that can reduce bond strength. On the other hand, an ARI score of “3” means less risk of enamel fracture after bracket debonding but polishing procedures are longer as more adhesive remains on tooth surface [9]. Therefore, an orthodontic biomaterial should aspire to a mixed adhesion modality (ARI “1” and “2”). In conclusion, bonding studies represent one of the first steps of materials testing and should be followed by in vivo clinical studies in order to confirm the in vitro results. Therefore, although some criticisms have been stated against bonding studies in orthodontics, bonding tests are still a valid instrument to test new brackets, adhesives, jigs, pad, and other biomaterials bonded to tooth surface. On the basis of these considerations, the present special issue has been proposed to explore new variables of bonding studies. These new topics have been about the Er:YAG laser-recycled ceramic orthodontic brackets, the transmission of curing light through treated dental tissues, the effect of removal of enamel on rebonding strength of resin composite, the bond strength of different bonding systems on enamel and restorative materials, and the bonding of metal attachments to sandblasted porcelain and zirconia. The Guest Editors do hope that the present special issue would be interesting for the readers of the journal and wish that the present work could encourage other researchers for future, original, interesting bond strength studies

    Effects of fluorosed enamel on orthodontic bracket bonding: An in vitro study

    No full text
    Objective: To investigate the effect of enamel deproteinization and air abrasion on shear bond strength (SBS), adhesive remnant index (ARI) scores, and surface topography when bonding orthodontic brackets to fluorosed enamel. Materials and methods: The sample included 90 fluorosed and 30 normal premolars divided into four groups: group I (fluorosed premolars subjected to air abrasion before acid etching), group II (fluorosed premolars subjected to deproteinization before acid etching), group III (fluorosed premolars; control for groups I and II), and group IV (normal premolars; control for group III). Bonding procedures included etching with 37% phosphoric acid, priming with TransbondTM XT primer (3M Unitek, Monrovia, CA, USA), and application of TransbondTM XT adhesive paste (composite; 3M Unitek, Monrovia, CA, USA). Air abrasion was done using 50 μm aluminum oxide particles under 0.28 MPa pressure for 5 s with the micro-etcher held at a distance of 10 mm. Deproteinization was done for 60 s with 5% sodium hypochlorite (NaOCl). Results: Fluorosed premolars subjected to deproteinization showed the lowest (median = 6.57 MPa) SBS among the four groups, followed by 8.14, 8.90, 8.14 MPa for groups I, III, and IV respectively. ARI scores were significantly different between the four groups (p = 0.006). Fluorosed enamel etched after air abrasion or deproteinization with NaOCl showed a predominance of type 4 etching pattern with some areas appearing unetched. Conclusions: Shear bond strength of all groups was within the 6–8 MPa acceptable range for orthodontic purposes. Fluorosed premolars subjected to deproteinization showed the lowest values. Further studies are recommended to scrutinize the deproteinization technique

    Imaging software programs for reliable mathematical measurements in orthodontics

    No full text
    Aim: To evaluate the reliability of linear and angular measurements taken using different software programs in orthodontics. Materials and Methods: A sample of four software programs from different manufacturers, namely MicroDicom viewer, Photoshop® CS3, AutoCAD®, and Image-Pro®, were used for measuring the geometric features of four types of miniscrews from different manufacturers. Each miniscrew type presented a group: Group I, Tomas® (Dentaurum, Ispringen, Germany); Group II, HUBIT® (HUBIT, Gyeonggi-do, Korea); Group III, AbsoAnchor® (Dentos, Daegu, Korea); and Group IV, Creative (Creative, Zhejiang, China). Measurements of apical face angle, thread angle, lead angle, flank, pitch depth, and width were taken on 45 × magnification scanning electron microscope images of the shafts of the miniscrews. One assessor measured the seven geometric features for the four types of miniscrews using the four software programs twice in two sessions separated by a three week interval. Results: Pairwise comparisons, for each of the four miniscrew groups, showed that the only common result observed was the significant difference (p < 0.001) between measurements of flank taken by the four software programs. When measurements of the four types of miniscrews were pooled into one group, a high degree of intra-rater reliability (ICC range from 0.9 to 1.0) for all the seven geometric features was found with all the four software programs. The paired t-test showed insignificant difference (at p ≤ 0.05) between the first and second measurements, except for a few measurements including pitch width measured by Image-Pro® (p = 0.012), MicroDicom (p = 0.023), and Photoshop® (p = 0.001). Conclusions: Results did not give absolute superiority to one software program over the others and suggested an assessor effect. Assessor estimates could have been affected, among other factors, by the design of the miniscrews and the technical features of the software programs

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Properties of CAD/CAM 3D Printing Dental Materials and Their Clinical Applications in Orthodontics: Where Are We Now?

    No full text
    In the last years, both medicine and dentistry have come across a revolution represented by the introduction of more and more digital technologies for both diagnostic and therapeutic purposes. Additive manufacturing is a relatively new technology consisting of a computer-aided design and computer-aided manufacturing (CAD/CAM) workflow, which allows the substitution of many materials with digital data. This process requires three fundamental steps represented by the digitalization of an item through a scanner, the editing of the data acquired using a software, and the manufacturing technology to transform the digital data into a final product, respectively. This narrative review aims to discuss the recent introduction in dentistry of the abovementioned digital workflow. The main advantages and disadvantages of the process will be discussed, along with a brief description of the possible applications on orthodontics

    Home Oral Care with Biomimetic Hydroxyapatite vs. Conventional Fluoridated Toothpaste for the Remineralization and Desensitizing of White Spot Lesions: Randomized Clinical Trial

    No full text
    Introduction: Biomimetic hydroxyapatite-based toothpastes have been investigated in recent years for their remineralizing activity on dental surfaces. The aim of the present study was to evaluate the efficacy of toothpaste containing biomimetic hydroxyapatite versus a 1450 pppm fluoride one in promoting the remineralization and desensitization of white spot lesions. Methods: 40 patients were randomly assigned to two different domiciliary oral hygiene treatments: toothpaste containing 1450 ppm of fluoride (control group) and toothpaste containing biomimetic hydroxyapatite (experimental group). Dental sensitivity/pain and dental erosion were assessed at baseline and after 15, 30, and 90 days using the following indexes: Schiff Air Index (SAI), Visual Analogue Scale (VAS), and Basic Erosive Wear Examination (BEWE). Results: Data were submitted for statistical analysis. SAI significantly decreased after 3 months (T3) of treatment only in the Trial group (p < 0.05). VAS values significantly decreased at T2 in the trial group (p < 0.05) with a further significant reduction at T3 (p < 0.05). BEWE scores did not significantly vary during the follow up neither in the trial nor in the control group. Conclusions: The hydroxyapatite-based toothpaste tested caused a reduction of hypersensitivity/pain values higher than conventional fluoride toothpaste

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore