1,721,012 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Neutron production from a mobile linear accelerator operating in electron mode for intraoperative radiation therapy
Intraoperative electron beam radiotherapy is increasingly performed using mobile linac delivering therapeutic radiation doses in unshielded operating rooms. While no special neutron-shielding problem should arise for operation at 10 MeV or less, it is not clear whether this holds true for operation at higher energies. This paper reports the measured neutron production from a Mobetron mobile electron linac, operated at 12 MeV, and compares the results with those from a conventional linac, also operated at 12 MeV in electron mode. Neutron leakage measurements were performed by means of passive bubble detectors in the scattering foil, patient and floor planes. Neutron dose equivalent rates per unit of electron dose delivered by the Mobetron at its normal treatment distance (50 cm SSD) were 0.33 microSv Gy(-1) at the accelerator head, 0.18 microSv Gy(-1) in the patient plane at 15 cm from the beam axis and 0.31 microSv Gy(-1) at the floor plane, on the beam axis and under the beam stopper. For a weekly workload of 250 Gy, the weekly neutron dose equivalents at 12 MeV for the Mobetron at a distance of 300 cm from the scattering foil were 14.3 and 1.7 microSv/week for floor below and adjoining areas on the same floor, respectively. Neutron dose equivalent rates generated from Mobetron are at least one order of magnitude lower than ones produced by a conventional linac operated at the same energy in electron mode. Mobetron can be used at 12 MeV in an unshielded operating room for a weekly workload of up to 250 Gy if the bremsstrahlung x-rays are shielded to negligible levels
Ultra-Hypofractionation for Whole-Breast Irradiation in Early Breast Cancer: Interim Analysis of a Prospective Study
We report on the early clinical outcomes of a prospective series of early breast cancer (EBC) patients treated with ultra-hypofractionated post-operative whole-breast irradiation (WBI) after breast-conserving surgery (BCS) and axillary management. Primary endpoints were patient's compliance and acute toxicity. Secondary endpoints included physician-rated cosmesis and ipsilateral breast tumour recurrence (IBTR). Acute toxicity was evaluated at the end of WBI, 3 weeks and 6 months thereafter, according to the Common Terminology Criteria for Adverse Events (v. 5.0). Patients were treated between September 2021 and May 2022. The treatment schedule for WBI consisted of either 26 Gy in 5 fractions over one week (standard approach) or 28.5 Gy in 5 fractions over 5 weeks (reserved to elders). Inverse planned intensity-modulated radiation therapy (IMRT) was used employing a static technique. A total of 70 patients were treated. Fifty-nine were treated with the 26 Gy/5 fr/1 w and 11 with the 28.5 Gy/5 fr/5 ws schedule. Median age was 67 and 70 in the two groups. Most of the patients had left-sided tumours (53.2%) in the 26 Gy/5 fr/1 w or right-sided lesions (63.6%) in the 28.5 Gy/5 fr/5 ws group. Most of the patients had a clinical T1N0 disease and a pathological pT1pN0(sn) after surgery. Ductal invasive carcinoma was the most frequent histology. Luminal A intrinsic subtyping was most frequent. Most of the patients underwent BCS and sentinel lymph node biopsy and adjuvant endocrine therapy. All patients completed the treatment program as planned. Maximum detected acute skin toxicities were grade 2 erythema (6.7%), grade 2 induration (4.4%), and grade 2 skin colour changes. No early IBTR was observed. Ultra-hypofractionated WBI provides favourable compliance and early clinical outcomes in EBC after BCS in a real-world setting
Application of failure mode and effect analysis (FMEA) to intracranial sterotactic radiosurgery by linear accelerator
Purpose: The aim of this study was to analyze the application of the failure modes and effects analysis (FMEA) to intracranial stereotactic radiation surgery (SRS) by linear accelerator in order to identify the potential failure modes in the process tree and adopt appropriate safety measures to prevent adverse events (AEs) and near-misses, thus improving the process quality. Methods and materials: A working group was set up to perform FMEA for intracranial SRS in the framework of a quality assurance program. FMEA was performed in 4 consecutive tasks: (1) creation of a visual map of the process; (2) identification of possible failure modes; (3) assignment of a risk probability number (RPN) to each failure mode based on tabulated scores of severity, frequency of occurrence and detectability; and (4) identification of preventive measures to minimize the risk of occurrence. Results: The whole SRS procedure was subdivided into 73 single steps; 116 total possible failure modes were identified and a score of severity, occurrence, and detectability was assigned to each. Based on these scores, RPN was calculated for each failure mode thus obtaining values from 1 to 180. In our analysis, 112/116 (96.6%) RPN values were b60, 2 (1.7%) between 60 and 125 (63, 70), and 2 (1.7%) N125 (135, 180). The 2 highest RPN scores were assigned to the risk of using the wrong collimator's size and incorrect coordinates on the laser target localizer frame. Conclusion: Failure modes and effects analysis is a simple and practical proactive tool for systematic analysis of risks in radiation therapy. In our experience of SRS, FMEA led to the adoption of major changes in various steps of the SRS procedure
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Acceptance test of a commerciallly available software for automatic image registration of computed tomography (CT), magnetic resonance imaging (MRI) and 99mTc-methoxyisobutylisonitrile (MIBI) single-photon emission computed tomography (SPECT) brain images.
This note describes a method to characterize the performances of image fusion software (Syntegra) with respect to accuracy and robustness. Computed tomography (CT), magnetic resonance imaging (MRI), and single-photon emission computed tomography (SPECT) studies were acquired from two phantoms and 10 patients. Image registration was performed independently by two couples composed of one radiotherapist and one physicist by means of superposition of anatomic landmarks. Each couple performed jointly and saved the registration. The two solutions were averaged to obtain the gold standard registration. A new set of estimators was defined to identify translation and rotation errors in the coordinate axes, independently from point position in image field of view (FOV). Algorithms evaluated were local correlation (LC) for CT-MRI, normalized mutual information (MI) for CT-MRI, and CT-SPECT registrations. To evaluate accuracy, estimator values were compared to limiting values for the algorithms employed, both in phantoms and in patients. To evaluate robustness, different alignments between images taken from a sample patient were produced and registration errors determined. LC algorithm resulted accurate in CT-MRI registrations in phantoms, but exceeded limiting values in 3 of 10 patients. MI algorithm resulted accurate in CT-MRI and CT-SPECT registrations in phantoms; limiting values were exceeded in one case in CT-MRI and never reached in CT-SPECT registrations. Thus, the evaluation of robustness was restricted to the algorithm of MI both for CT-MRI and CT-SPECT registrations. The algorithm of MI proved to be robust: limiting values were not exceeded with translation perturbations up to 2.5 cm, rotation perturbations up to 10 degrees and roto-translational perturbation up to 3 cm and 5 degrees
- …
