170,102 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    No full text
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Mitomycin C in highly myopic eyes - Author reply

    No full text
    Ophthalmology. 2005 Feb;112(2):208-18; discussion 219. Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes. Gambato C, Ghirlando A, Moretto E, Busato F, Midena E. SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy. Abstract PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes. DESIGN: Prospective, double-masked, randomized clinical trial. PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia. METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months). MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH. RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively). CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK. Comment in Ophthalmology. 2006 Feb;113(2):357; author reply 357-8

    Eyes wide shut - unusual two stage repair of pectus excavatum and annuloaortic ectasia in a 37 year old marfan patient: Case report

    No full text
    We report about a 37 year old male patient with a pectus excavatum. The patient was in NYHA functional class III. After performed computed tomography the symptoms were thought to be related to the severity of chest deformation. A Ravitch-procedure had been accomplished in a district hospital in 2009. The crack of a metal bar led to a reevaluation 2010, in which surprisingly the presence of an annuloaortic ectasia (root 73 × 74 mm) in direct neighborhood of the formerly implanted metal-bars was diagnosed. Echocardiography revealed a severe aortic valve regurgitation, the left ventricle was massively dilated presenting a reduced ejection fraction of 45%. A marfan syndrome was suspected and the patient underwent a valve sparing aortic root replacement (David procedure) in our institution with an uneventful postoperative course. A review of the literature in combination with discussion of our case suggests the application of stronger recommendations towards preoperative cardiovascular assessment in patients with pectus excavatum

    Dispelling the Myths Behind First-author Citation Counts

    No full text
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    A Multi-Language Comparison of Influences on Author Verification using Character N-Grams

    No full text
    We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc

    A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C

    No full text
    Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (&gt; 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic

    Neointimal inflammation and adventitial angiogenesis correlate with severity of cardiac allograft vasculopathy in pediatric recipients

    No full text
    Background: Chronic inflammation and angiogenesis have been implicated in the pathogenesis of both cardiac allograft vasculopathy (CAV) and age-related vasculopathy. Because concurrent atherosclerosis does not complicate assessment of CAV in children, we sought to characterize the spectrum of coronary lesions in this population and determine whether inflammatory. infiltrates and angiogenesis correlate with severity of CAV. Methods: In 18 pediatric heart specimens CAV was graded 1 to 4 (none to severe). Each case was assigned to either: Group 1, no inflammation; Group 11, perivascular inflammation; or Group 111, perivascular and neointimal inflammation. Inflammatory infiltrates were immunophenotyped using anti-CD3, antiCD20 and HAM 56. Angiogenesis was assessed by determining microvascular density (MVD) in 5 high-power fields (HPFs),per section. Results: CAV was evident in 94% of cases, and inflammation in 61%. Cases with neointimal inflammation had significantly more severe CAV compared with cases without inflammation (2.7 +/- 0.16 vs 1.9 +/- 0.2, p = 0.002). MVD was significantly higher in both inflammation groups (Groups 11 and III) compared with Group 1 (4.1 +/- 0.5 per HPF and 5.9 +/- 0.5 vs 3.1 +/- 0.7, p = 0.018 and p = 0.002) and correlated with the degree of CAV (p = 0.007). The perivascular infiltrates (Group II, n = 5) contained lymphocytes, macrophages and plasma cells, and 67% of neointimal infiltrates (Group 111, n = 6) also contained eosinophils. Conclusions: CAV in children is more common than previously reported. Our data indicate that CAV is often associated with inflammation and that adventitial angiogenesis correlated with the severity of CAV

    A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration

    No full text
    Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
    corecore