1,721,033 research outputs found
Discovery of a correlation between the frequency of the mHz quasi-periodic oscillations and the neutron-star temperature in the low-mass X-ray binary 4U 1636–53
We detected millihertz quasi-periodic oscillations (QPOs) in an XMM–Newton observation of the neutron-star low-mass X-ray binary 4U 1636-53. These QPOs have been interpreted as marginally stable burning on the neutron-star surface. At the beginning of the observation the QPO was at around 8 mHz, together with a possible second harmonic. About 12 ks into the observation a type I X-ray burst occurred and the QPO disappeared; the QPO reappeared ~25 ks after the burst and it was present until the end of the observation. We divided the observation into four segments to study the evolution of the spectral properties of the source during intervals with and without mHz QPO. We find that the temperature of the neutron-star surface increases from the QPO segment to the non-QPO segment, and vice versa. We also find a strong correlation between the frequency of the mHz QPO and the temperature of a blackbody component in the energy spectrum representing the temperature of neutron-star surface. Our results are consistent with previous results that the frequency of the mHz QPO depends on the variation of the heat flux from the neutron-star crust, and therefore supports the suggestion that the observed QPO frequency drifts could be caused by the cooling of deeper layers
Discovery of an accretion-rate Independent absolute RMS amplitude of millihertz quasi-periodic oscillations in 4U 1636-53
We investigate the frequency and amplitude of the millihertz quasi-periodic oscillations (mHz QPOs) in the neutron-star low-mass X-ray binary 4U 1636–53 using Rossi X-ray Timing Explorer observations. We find that no mHz QPOs appear when the source is in the hard spectral state. We also find that there is no significant correlation between the frequency and the fractional RMS amplitude of the mHz QPOs. Notwithstanding, for the first time, we find that the absolute rms amplitude of the mHz QPOs is insensitive to the parameter S a , which measures the position of the source in the color–color diagram and is usually assumed to be an increasing function of mass accretion rate. This finding indicates that the transition from marginally stable burning to stable burning or unstable burning could happen very rapidly since, before the transition, the mHz QPOs do not gradually decay as the rate further changes
Millihertz quasi-periodic oscillations in 4U 1636-53 associated with bursts with positive convexity only
We investigated the convexity of all type I X-ray bursts with millihertz quasi-periodic oscillations (mHz QPOs) in 4U 1636?53 using archival observations with the Rossi X-ray Timing Explorer. We found that, at a 3.5? confidence level, in all 39 cases in which the mHz QPOs disappeared at the time of an X-ray burst, the convexity of the burst is positive. The convexity measures the shape of the rising part of the burst light curve and, according to recent models, it is related to the ignition site of bursts on the neutron-star surface. This finding suggests that in 4U 1636-53 these 39 bursts and the marginally stable nuclear burning process responsible for the mHz QPOs take place at the neutron-star equator. This scenario could explain the inconsistency between the high accretion rate required for triggering mHz QPOs in theoretical models and the relatively low accretion rate derived from observations
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
