    Stabilizing bioimpedance-vector-analysis measures with a 10-minute cold shower after running exercise to enable assessment of body hydration

    No full text
    Purpose: The exercise-induced increase in skin and body temperature, cutaneous blood flow, and electrolyte accumulation on the skin affects the validity of bioimpedance analysis to assess postexercise changes in hydration. This study aimed to assess the influence of a 10-min cold (22°C) shower on the time course of impedance measurements after controlled exercise. Methods: In total, 10 male athletes (age 26.2 [4.1] y and body mass index 23.9 [1.7] kg/m2) were tested on 2 different days. During both trials, athletes ran for 30 min on a treadmill in a room at 23°C. In a randomized crossover trial, the participants underwent a 10-min cold shower on the trial occasion and did not shower in the control trial. Bioimpedance analysis variables were measured before running (ie, baseline [T0]), immediately after exercising (T1), and 20 (T2), 40 (T3), and 60 min (T4) after the exercise. The shower was performed after T1 in the shower trial. Results: Body weight decreased similarly in both trials (−0.4% [0.1%], P < .001; −0.4% [0.1%], P < .001). Resistance and vector length returned to baseline at T2 in the shower trial, whereas baseline values were achieved at T3 in the control trial (P > .05). In the control trial, reactance remained at a lower level for the entire testing period (38.1 [6.9] vs 37.3 [6.7], P < .001). Forehead skin temperature returned to baseline values at T2 with shower, whereas it was still high at T4 without shower (P < .001). Conclusions: The present data show that a 10-min cold shower enables the stabilization of bioimpedance analysis measurements within 20 min after exercise, which might facilitate the assessment of hydration change after exercise

    Bioelectrical Impedance Vector Analysis for Assessment of Hydration in Physiological States and Clinical Conditions

    No full text
    Although the importance of assessing hydration is well recognized, traditional laboratory methods and clinical impressions are impractical or lack sensitivity to be useful in physiological and clinical conditions. Alternate approaches using bioelectrical impedance measurements to estimate fluid volumes utilize regression equations and depend on physical models unproven in physiological systems; they result in large errors in the prediction of fluid volumes notably in individuals with altered hydration. Bioelectrical impedance vector analysis (BIVA) overcomes these limitations because it only uses determinations of resistance (R) and reactance (Xc) normalized for height and yields a vector of specific magnitude (length) and direction (phase angle). This vector, for either an individual or a group, is evaluated on the bivariate R–Xc graph, which is a probability distribution derived from a reference population of healthy, matched controls. Comparison of an individual or group vector to the mean vector of the reference population provides reliable and accurate classification and ranking of hydration that is independent of body weight. Applications of BIVA in healthy adults include assessment of over-hydration in pregnancy and weight loss in obesity. BIVA also has broad uses in the evaluation and management of clinical groups including the characterization of patterns of hydration change during hemodialysis (HD) and peritoneal dialysis and use of this information to prescribe dialytic therapy; identification of under-hydration in critically ill patients and guidance for administration of fluid therapy; assessment and monitoring of tissue hydration status in congestive heart failure; and identification of regional edema in patients after vascular surgery. Because of its practicality and reliability, BIVA can be used in observational and longitudinal studies of hydration in patient care and management and in field conditions

    Prediction of somatotype from bioimpedance analysis in elite youth soccer players

    Full text link
    The accurate body composition assessment comprises several variables, causing it to be a time consuming evaluation as well as requiring different and sometimes costly measurement instruments. The aim of this study was to develop new equations for the somatotype prediction, reducing the number of normal measurements required by the Heath and Carter approach. A group of 173 male soccer players (age, 13.6 ± 2.2 years, mean ± standard deviation; body mass index, BMI, 19.9 ± 2.5 kg/m2), members of the academy of a professional Italian soccer team participating in the first division (Serie A), participated in this study. Bioelectrical impedance analysis (BIA) was performed using the single frequency of 50 kHz and fat-free mass (FFM) was calculated using a BIA specific, impedance based equation. Somatotype components were estimated according to the Heath-Carter method. The participants were randomly split into development (n = 117) and validation groups (n = 56). New anthropometric and BIA based models were developed (endomorphy = −1.953 − 0.011 × stature2/resistance + 0.135 × BMI + 0.232 × triceps skinfold, R2 = 0.86, SEE = 0.28; mesomorphy = 6.848 + 0.138 × phase angle + 0.232 × contracted arm circumference + 0.166 × calf circumference − 0.093 × stature, R2 = 0.87, SEE = 0.40; ectomorphy = −5.592 − 38.237 × FFM/stature + 0.123 × stature, R2 = 0.86, SEE = 0.37). Cross validation revealed R2 of 0.84, 0.80, and 0.87 for endomorphy, mesomorphy, and ectomorphy, respectively. The new proposed equations allow for the integration of the somatotype assessment into BIA, reducing the number of collected measurements, the instruments used, and the time normally required to obtain a complete body composition analysis

    Fat-free Mass Bioelectrical Impedance Analysis Predictive Equation for Athletes using a 4-Compartment Model

    No full text
    Bioelectrical impedance analysis equations for fat-free mass prediction in healthy populations exist, nevertheless none accounts for the inter-athlete differences of the chemical composition of the fat-free mass. We aimed to develop a bioimpedance-based model for fat-free mass prediction based on the four-compartment model in a sample of national level athletes; and to cross-validate the new models in a separate cohort of athletes using a 4-compartment model as a criterion. There were 142 highly trained athletes (22.9±5.0 years) evaluated during their respective competitive seasons. Athletes were randomly split into development (n=95) and validation groups (n=47). The criterion method for fat-free mass was the 4-compartment model. Resistance and reactance were obtained with a phase-sensitive 50 kHz bioimpedance device. Athletic impedance-based models were developed (fat-free mass=- 2.261+0.327*Stature 2/Resistance+0.525*Weight+5.462*Sex, where stature is in cm, Resistance is in Ω, Weight is in kg, and sex is 0 if female or 1 if male). Cross validation revealed R 2of 0.94, limits of agreement around 10% variability and no trend, as well as a high concordance correlation coefficient. The new equation can be considered valid thus affording practical means to quantify fat-free mass in elite adult athletes

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    A Smartphone Application for Personal Assessments of Body Composition and Phenotyping

    No full text
    Personal assessments of body phenotype can enhance success in weight management but are limited by the lack of availability of practical methods. We describe a novel smart phone application of digital photography (DP) and determine its validity to estimate fat mass (FM). This approach utilizes the percent (%) occupancy of an individual lateral whole-body digital image and regions indicative of adipose accumulation associated with increased risk of cardio-metabolic disease. We measured 117 healthy adults (63 females and 54 males aged 19 to 65 years) with DP and dual X-ray absorptiometry (DXA) and report here the development and validation of this application. Inter-observer variability of the determination of % occupancy was 0.02%. Predicted and reference FM values were significantly related in females (R2 = 0.949, SEE = 2.83) and males (R2 = 0.907, SEE = 2.71). Differences between predicted and measured FM values were small (0.02 kg, p = 0.96 and 0.07 kg, p = 0.96) for females and males, respectively. No significant bias was found; limits of agreement ranged from 5.6 to −5.4 kg for females and from 5.6 to −5.7 kg for males. These promising results indicate that DP is a practical and valid method for personal body composition assessments

    Different displacement of bioimpedance vector due to Ag/AgCl electrode effect

    No full text
    Background/Objectives:Bioelectrical impedance vector analysis (BIVA) is increasingly used in clinical research to assess soft tissue hydration. It is known that physical characteristics of electrodes, such as low intrinsic impedance, low electrode/skin contact impedance and type of gel, affect the reliability of noninvasive bioimpedance assessments. The aim of this study was to determine the effect of intrinsic impedance of electrode on the bioimpedance vector displacement in RXc graph.Subjects/Methods:The intrinsic impedance is measured in nine pregelled disposable Ag/AgCl electrodes usually used for bioimpedance measures. The BIVA method is performed on 35 healthy volunteers using a 50 kHz phase-sensitive bioimpedance analyzer (BIA 101 Anniversary) with the lowest intrinsic impedance electrode and highest. The individual bioimpedance vector is plotted on the bivariate normal interval of reference population. The differences in the mean bioimpedance vectors obtained with each electrode are plotted, with their 95% confidence ellipses, on the dRXc graph. The paired one-sample Hotelling's T 2 -test is used to compare the differences of the mean bioimpedance vectors.Results:We found large variability in intrinsic resistance (11-665 Ω) and reactance (0.25-2.5 Ω) values of the electrodes analyzed and significant displacement (P<0.05) of bioimpedance vector positions in healthy adults according to the paired one-sample Hotelling's T 2 -test.Conclusions:A robust study of all physical characteristics of commercial Ag/AgCl electrodes is necessary to reach consensus on pregelled Ag/AgCl electrodes valid for bioimpedance measurement. This information will enable BIVA users to avoid systemic errors when performing BIVA assessments, specifically when these measurements are used for clinical interpretations